Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Indoor use only
instructions
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
Ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections
9
to ensure that none are loose.
Ensure that the voltage marked on the appliance matches the power supply to be
9
used and that the plug is fitted with the correct fuse - see fuse rating at right.
DO NOT use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
8
replaced immediately by a competent electrician.
It is recommended that this device is wired directly to a fused isolator switch. If, however, a plug
9
is fitted, the following applies:
Fit a new plug according to the following instructions (UK only).
9
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
1.2.
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
This tool must be placed on its stand when not in use.
9
Caution-High Temperature Operation
9
DO NOT use the Surface Mounted Device unit near ignitable gases, paper, or other inflammable materials.
8
The nozzle air is extremely hot and can cause painful burns. Never touch the heater pipe or allow the heated air to blow against your
9
skin.
DO NOT disassemble the product.
8
Disconnect the plug when you don't use the unit for a long time.
9
When the power cord is connected into the power supply, the unit has a little flow of electricity, even the Power Switch is in off
9
position. So then you don't use the unit for a long time, disconnect the plug.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
2. INTRODUCTION
300W Hot air rework station with automatic cooling system. LED digital display, showing current temperature and status. MCU confirms fast
heat up, accurate & stable control on temperature. Temperature Range: 100-500°C. Suitable for desoldering work on various components such
as SOIC, CHIP, QFP, PLCC and BGA. Includes three nozzles.
3. SPECIFICATION
MODEL NO: ............................................................... SD007
Brand: ......................................................................... Sealey
Electrical Plug Type: ................................................ 3-Pin BS
Frequency: .....................................................................50Hz
Power: ...........................................................................300W
© Jack Sealey Limited
300W HOT AIR REWORK STATION
MODEL NO:
Hot surfaces
Original Language Version
SD007
Recommended fuse rating
3 Amp
SD007 Issue 1 28/01/2021

Advertisement

loading

Summary of Contents for Sealey SD007

  • Page 1 SD007 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...