Page 2
In connection with the transfer of possession of the software package LICENSOR warrants that under normal use, SOFTWARE shall perform provided with this Agreement, Motorola, (LICENSOR) hereby grants to the functions specified in its DOCUMENTATION. If SOFTWARE does not possessor (LICENSEE) a non-exclusive license to use the software program(s)
Page 3
Accordingly, any copyrighted Motorola computer programs contained in the Motorola products described in this manual may not be copied or reproduced in any manner to the extent allowed by law without the express written permission of Motorola.
Getting Started ........................1 Equipment Required ....................... 1 Programming Interface ....................1 Installing the Programmer Software ................2 Connecting Programmer to Minitor IV................2 Initializing Minitor IV for Programming................ 4 Launching the Application....................5 Commands ........................6 System Setup........................7 Programming User Data ....................
USB port instead of the COM port Programming Interface The programming interface kit, shown in Figure 1, supports Minitor IV codeplug programming. Items included with the interface kit consist of the following: •...
Please follow the procedure below to complete the installation. 1. Insert the Minitor IV Pager Programming Software CD into your CD drive. The installation software should be launched automatically. Note: If it does not launch by itself, browse your CD drive using Windows Explorer, select the setup.exe at the root of your CD drive, and double click on it.
Page 7
3. Connect the programmer cable end with the phone jack to the programming interface. 4. Plug the coiled cable into the Minitor IV programmer nest and programming interface. 5. Connect AC/DC adapter/power supply to programming interface. 6. Plug AC/DC adapter/power supply into wall outlet.
6. Release the reset button as soon as the events in Step 5 occur. 7. Observe the position of the programming pins and insert the Minitor IV into the programming nest. The red indicator on the programming interface should light.
Minitor IV Pager Programming Guide Getting Started Launching the Application The application can be launched from Start → Programs → Minitor PPS → Minitor4 PPS. The following window appears, Figure 5 Minitor Win PPS Interface 6880309M81-A 9/20/2004...
Pager Programming Guide Minitor IV Troubleshooting Guide Commands The following table lists all Minitor PPS commands. Menu Command Icon Description File Open Open a Minitor codeplug file. The file has the extension “.dat”. Save Save the current codeplug data to a file.
Minitor IV Pager Programming Guide Getting Started The first command required to program the pager is the “Read” command. It can either read from a pager or an archived files. After the Read command, user can view/modify the codeplug data, save the codeplug data to a file, or write directly to a pager.
Pager Programming Guide Minitor IV Troubleshooting Guide Programming User Data User Data are organized into at least 4 pages in the User Data property sheet. They are General Information, Channel, Model Option and Function Switches. General Information Figure 8 General Information Page...
Minitor IV Pager Programming Guide Getting Started Group Field Name Description Pager Model Number This non-editable field displays the model Information number programmed into the pager at the factory and should match the model number on one of the labels attached to the pager.
Page 14
Pager Programming Guide Minitor IV Troubleshooting Guide Figure 9 Channel Page Group Field Name Description Receiver Enter the frequency of operation for the Frequency channel. Channel frequency entry must be within the band split range. Call Tone Coding Option Select one of available configuration (R468, R130, R97, options.
Page 15
Getting Started Figure 10 Channel Page with Tone System other than USER Here is an example of tone table for MOTOROLA tones. When Motorola is selected as System Tone, all call tones must match the tone listed in this table.
Pager Programming Guide Minitor IV Troubleshooting Guide Model Options Figure 12 Model Option Page 9/20/2004 6880309M81-A...
Page 17
Minitor IV Pager Programming Guide Getting Started Group Field Name Description Model Stored Voice Enable or disable stored voice models with this Option Function option Fixed Alert Select either ON or OFF. If ON is selected, the pager operates in the “fixed alert” mode. This means the tone alert is at maximum volume regardless of the position of the volume control.
Pager Programming Guide Minitor IV Troubleshooting Guide Function Switches Figure 13 Function Switches Page 9/20/2004 6880309M81-A...
Page 19
Minitor IV Pager Programming Guide Getting Started Group Field Name Description Function Switch The function switch has four programmable Switches Position positions (SW-A, SW-B, SW-C and SW-D) Option When an option number is selected in the OPTION (0 ~ 15)
Computer 1. Minitor is not setup Refer to installation and software can not correctly for programming Setup and perform read Minitor IV initialization procedure codeplug 2. Com port selection Check the COM port connection and set the COM port accordingly...
Minitor IV Pager Programming Guide Ordering and Parts Information Ordering and Parts Information Available programmer parts are listed in Table 8 Description Part Number Programmer nest, software, and manual RLN5832A Programmer nest only NYN8355A Software CD w/ Programming Manual RVN4239A...