Available languages

Available languages

36W
Fig. 3
Ne pas installer á l'envers
au sur le côté
Fig. 5
Decalage recommandé : 304,8 mm (12 po) au-dessus et au-dessous de l'appareil de chauffage "6" (152,4 mm) devant et sur les côtés de
l'appareil de chauffage
ATTENTION : Veuillez garder tout matériau inflammable à au moins 24 po (609,6 mm) du chauffe-eau et du tuyau de sortie d' e au
chaude.
5. Plumbing Requirements and Precautions
• Please follow all plumbing instructions carefully. This product must be installed in accordance
with all national, state, provincial, and local plumbing codes. We recommend consulting with
your municipality or a qualified plumber if you have questions relating to plumbing codes for your
area prior to installing.
• The plumbing installation must be completed before the electrical installation.
• DO NOT solder any pipe with the unit connected to the pipe. The heat from soldering may cause
damage to the flow sensor. Doing so will void the warranty.
• The use of a temperature pressure relief valve (T&P) is not required for most installations because
the tankless water heater does not use a storage tank. UL Standard 499 does not require that a
pressure relief valve is used, although it may be needed to meet installation codes in your area.
In such cases, the pressure relief valve should be installed in accordance with local codes. It is important to ensure that the unit is
operating correctly, and that air is purged from the valve prior to installing the water heater.
• A T&P valve is recommended for added safety when connecting to plumbing rated Metal, Flex or High-Temperature CPVC piping.
NOTE: A pressure relief valve is required for installations in the Commonwealth of Massachusetts and State of
Kentucky. Please check your local installation codes for any special requirements.
• The plumbing installation requires piping that can withstand pressure up to 8 BAR.
118
F
º
temp
Fig. 4
Fig. 6
Fig. 7
Pré-Filtre á
eau
Do not solder any piping to the
unit's Connection points
47