Changing / Inspecting the Carbon Brushes

The carbon brushes in conjunction with the AVR regulates power from the generator. The
carbon brushes are wearable parts and should be inspected every 250 running hours.
1.
Remove generator cover
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
2.
Remove bolt from brush
Remove the bolt holding the carbon brush.
3.
Disconnect AVR wires
Remove the two wires from the AVR on the carbon brush
55

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DUAL FUEL XP13000EH and is the answer not in the manual?

Questions and answers

Bridget Brahney
January 19, 2025

On both fuel sources it wants to start, but the engine just won’t turn over

Kipp Horrocks
March 1, 2025

I need directions to replace a starter

David Haskins
March 15, 2025

Brand new XP13000EH keeps popping the 120 plug reset/test circuit breaker after 3-5 seconds of power.