DUROMAX XP10000E User Manual
Hide thumbs Also See for XP10000E:

Advertisement

XP10000E GENERATOR
User Manual
REV: XP10000E-07072020
5800 Ontario Mills Pkwy
Ontario, CA 91764 USA
This manual provides information regarding the operation
www.duromaxpower.com
and maintenance of these products. We have made every
effort to ensure the accuracy of the information in this
Call our Customer Care Team Toll Free 8-5pm PST Mon-Fri
manual. We reserve the right to change this product at
844-DUROMAX
any time without prior notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XP10000E and is the answer not in the manual?

Questions and answers

Summary of Contents for DUROMAX XP10000E

  • Page 1 XP10000E GENERATOR User Manual REV: XP10000E-07072020 5800 Ontario Mills Pkwy Ontario, CA 91764 USA This manual provides information regarding the operation www.duromaxpower.com and maintenance of these products. We have made every effort to ensure the accuracy of the information in this Call our Customer Care Team Toll Free 8-5pm PST Mon-Fri manual.
  • Page 3: Table Of Contents

    CONTENTS Introduction Introduction ........................6 General Safety Procedures ................... 7 Quick Start Guide (Gasoline) ..................10 Quick Start Guide (Propane) ..................12 Generator Components ....................14 Package Contents ......................16 Generator Setup Shipping Braces ......................18 Wheel Kit Installation ....................19 Adding Oil ........................
  • Page 4 CONTENTS Maintenance and Care Maintenance Schedule ....................40 Maintenance Log ......................41 Checking the Oil ......................42 Changing the Oil ......................43 Cleaning the Air Filter ....................44 Spark Plug Maintenance ....................46 Emptying the Gas Tank ....................48 Cleaning the Fuel Filter Cup ..................50 Storage and Transportation ..................
  • Page 6 DUROMAX The DuroMax Way is more than just a brand, it is our understanding and appreciation of just how important power can be to someone without it… DUROMAX FOR HOME DUROMAX FOR WORK DUROMAX FOR PLAY Electricity in our home not...
  • Page 7: Introduction

    INTRODUCTION DuroMax Power Equipment is headquartered in Ontario, California and is the industry’s leader in Dual Fuel portable generator technology. In addition to a full assortment of portable generators ranging from digital inverters to large 15,000-watt portable standby units, their product line includes pressure washers, engines, pumps, and accessories.
  • Page 8: General Safety Procedures

    GENERAL SAFETY PROCEDURES SAFETY ALERT SYMBOL The safety alert symbol is used with one of the safety words (DANGER, CAUTION, or WARNING) to alert you of hazards. Please pay attention to these hazard notices both in this manual and on the generator. Please familiarize yourself with the following safety symbols and words: DANGER: Indicates a hazard that will result in serious injury or death if instructions are not ●...
  • Page 9 WARNING: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline. Do not operate near an open flame. ●...
  • Page 10 GENERAL SAFETY PROCEDURES In addition to the above safety notices, please familiarize yourself with the safety and hazard markings on the generator. DANGER DO NOT OVERFILL 1.5” THE GAS TANK OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH.
  • Page 12 UNIT AND PURCHASE INFORMATION Serial Number Serial Number The serial number is located on the engine block, above and to the left of the oil fill. Serial number format The serial number will be shown in two parts. The engine model, followed by the serial number.
  • Page 13 As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, odorless threat.
  • Page 15 QUICK START The Quick Start of your generator is the minimum necessary setup that will get you going as soon as possible. Be sure to read the instructions starting on pg. 25 for full setup instructions.
  • Page 16: Quick Start Guide (Gasoline)

    QUICK START GUIDE Remove shipping braces The shipping braces prevent engine movement during shipment. Flip the generator over and remove the brightly colored brace between the motor and the frame, and the wood brace under the generator. Add oil The oil fill cap is located on the lower engine block to the right of the recoil start housing.
  • Page 17 Close choke The choke lever is located above the air filter to the left of the recoil start. Slide the lever to the left to cut the air supply and allow more gas into the engine to start. Start generator The switch is located on the left side of the front power panel.
  • Page 18: Generator Components

    GENERATOR COMPONENTS 8. 120v 3-Prong Receptacle 19. 120V 3 Prong Twist 20. 120/240v 4-Prong Lock Receptacle 2. Choke Lever 21. Auto Throttle 5. Circuit Breaker 10. Volt Meter 1. Power Boost 16. Fuel Valve 7. Ground Terminal 1. Air Filter 11.
  • Page 19 15. Fuel Filter Cup 3. Fuel Gauge 4. Fuel Cap 17. Spark Plug 18. Muffler 12. Oil Fill and Dipstick - Use to add or check the oil. 13. Engine Switch – 3 Position Switch to “Start”, “Run”, or turn “Off” the generator. 14.
  • Page 20: Package Contents

    PACKAGE CONTENTS Your generator comes with the items listed below. Please check to see that all of the following items are included with your generator. Double Sided Spanner Spark Plug Wrench Screw Driver Phillips and slot blade Assorted wrenches used in Used in spark plug screwdriver used for generator generator maintenance and...
  • Page 21: Generator Setup

    GENERATOR SETUP Proper setup of your generator will get you going as soon as possible while making sure you and your equipment are safe and cared for.
  • Page 23: Shipping Braces

    GENERATOR SETUP Step 1 - Remove Shipping Braces Unpack Remove the generator from the box. Place the largest piece of packing foam on a flat surface. Flip the generator upside down on the pad. CAUTION: NEVER Attempt this if you have put fuel or oil in the generator.
  • Page 24: Wheel Kit Installation

    GENERATOR SETUP (CONTINUED) Step 2 - Wheel Kit Installation (Optional) Install support legs Secure the support legs to the frame with the provided lock nuts. Install wheel axles Place the smallest washer onto the wheel axle bolts. Insert wheel axle bolts through the frame and secure with the provided nut and wrenches Install inside wheel washers Place one of the large washers onto the axles.
  • Page 25 Install outside wheel washers Place the other large washers onto the axles. Install cotter pins Place the cotter pin through the hole at the end of the axle and bend it out to secure the wheel. Install handles Attach the handles to the brackets on the frame using the provided bolts and nuts.
  • Page 26 GENERATOR SETUP (CONTINUED) Step 3 - Connect the Battery Remove the battery cover Remove the battery cover plate using the wrench from the toolkit. Locate the negative cable Locate the negative battery cable above and behind the battery. One side is connected to ground and the other end needs to be connected to the battery.
  • Page 27: Adding Oil

    . You must add the proper amount of oil before operating the generator for the first time. This amount is equal to the oil capacity of the engine crankcase: Model Number XP10000E Engine Oil Capacity 37 fl. oz (1.1L) WARNING: Do not apply engine oils with additives or 2-stroke gasoline engine oils. They don’t have enough lubrication and may shorten the engine’s service life.
  • Page 29: Grounding The Generator

    Step 6 - Grounding the Generator Attach grounding wire Ground the generator by tightening the grounding nut against a grounding wire. Connect the other end to a copper or brass grounding rod that’s driven into the earth. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire.
  • Page 31: Starting The Generator

    STARTING THE GENERATOR If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point, you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP”...
  • Page 32: Checking The Oil

    (see “Adding Oil” portion of the “Maintenance” section). Be sure to replace the cap when finished checking oil. Model Number XP10000E Engine Oil Capacity 37 fl. oz (1.1L)
  • Page 33: Check The Gas Level

    Step 2 - Check the gas level (Optional) Check fuel level If running the engine on gasoline check to see that there is sufficient gasoline in the fuel tank. The fuel gauge on top of the tank will give a rough estimate of the gasoline level. The gauge will appear white then fill red as the tank is filled.
  • Page 34 STARTING THE GENERATOR Starting the Generator Shut breaker off The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator. Turn gas valve on The gas valve is located above the recoil start on the bottom of the fuel tank.
  • Page 35 Turn engine switch to ON When the engine starts, allow the engine switch to return to the ON position. Open choke Push the choke to the OPEN position as the engine warms up. CAUTION: LPG must be shut off when using gasoline! CAUTION: Gasoline must be shut off when using LPG! CAUTION: Disconnect all electrical loads from the generator before attempting to start!
  • Page 36 STARTING THE GENERATOR (CONTINUED) Starting the Generator Using Recoil Start Shut breaker off The breaker is located on the right side of the front power panel. Flip the breaker down to prevent accidental load when starting the generator. Turn gas valve on The gas valve is located above the recoil start on the bottom of the fuel tank.
  • Page 37 Close choke The choke lever is located above the air filter to the right of the recoil start. Slide the lever to the left to cut the air supply and allow more gas into the engine to start. Pull the recoil start The recoil start is located on the left side panel next to the air filter.
  • Page 39: Using The Generator

    USING THE GENERATOR If this is not your first time using the generator, there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point, you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP”;...
  • Page 40: Ac Usage

    USING THE GENERATOR AC Usage ● You may connect electrical devices running on AC current according to their wattage requirements. The chart below shows the rated and surge wattage of your generator according to its model ● number. ● The rated wattage corresponds to the maximum wattage the generator can output on a continuous basis.
  • Page 41 Tool or Appliance Rated (Running) Watts Additional Surge Watts Electric water heater (40 gal) 4000 Hot plate 2500 Radial arm saw 2000 2000 Electric Stove 1500 Circular Saw 1500 1500 Air compressor (1 HP) 1500 3000 Window air conditioner 1200 1800 Miter saw 1200...
  • Page 42: Connecting A Load To The Generator

    USING THE GENERATOR (CONTINUED) Connecting a load to the generator NOTE: Be sure to attach devices to the correct receptacle (outlet). 120v devices can be directly connected to the 120v ONLY receptacles. ● 120v devices can be connected to the 120/240v receptacle using an appropriate adapter. ●...
  • Page 43: Voltage Selector Switch

    Voltage Selector Switch This generator features Power Boost Technology, which gives the user the ability to double the power in the generator for more heavy duty applications. The voltage selector switches the dual 120v AC windings of the generator to produce “120V ONLY” or “120/240V”. If a 240V appliance is connected to the 4-prong receptacle, the switch must be in the “120/240V”...
  • Page 44: Dc Usage

    USING THE GENERATOR (CONTINUED) USING THE GENERATOR (CONTINUED) DC Usage DC Usage CAUTION: The DC receptacle is for recharging 12 Volt automotive-type batteries only. Do not connect any other device to this receptacle. CAUTION: Never try to jump start a car with your generator. Connect the battery Connect one charging wire to the positive terminal on the battery and the other charging wire to the negative terminal...
  • Page 45 Connect negative receptacle Carefully connect the free end of the negative wire to the negative receptacle on the generator. Disconnecting When disconnecting, always disconnect the wires from the generator first to avoid a spark. DANGER - Stored batteries emit highly explosive hydrogen gas when charged. Batteries also contain acid, which can cause severe chemical burns.
  • Page 47: Maintenance And Care

    MAINTENANCE AND CARE Proper maintenance and storage of your generator are essential to ensure trouble-free use of your generator when you need it. By following the maintenance and care requirements, you can keep your generator running smoothly and efficiently for years to come.
  • Page 48: Maintenance Schedule

    MAINTENANCE AND CARE Proper routine maintenance of your generator is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING: Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously injured or killed. Always follow the inspection, maintenance recommendations, and schedules in this instruction manual.
  • Page 49: Maintenance Log

    MAINTENANCE LOG Date Generator Hours Maintenance Performed...
  • Page 50 MAINTENANCE AND CARE Proper routine maintenance of your generator is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING: Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously injured or killed. Always follow the inspection, maintenance recommendations, and schedules in this instruction manual.
  • Page 51 MAINTENANCE LOG Date Generator Hours Maintenance Performed...
  • Page 52: Cleaning The Air Filter

    MAINTENANCE AND CARE (CONTINUED) Cleaning the air filter Routine maintenance of the air cleaner helps maintain proper airflow to the carburetor. Check that the air cleaner is free of excessive dirt after every use. Note: Improper maintenance may cause less air to enter the engine or dirty air to enter the engine causing overheating and engine wear.
  • Page 53 Wash cleaner element Wash the sponge-like elements in household dish detergent and warm water. Dry cleaner element Pat dry on a dry cloth and allow the elements to dry completely. Add engine oil to elements Soak the dry elements in a small amount of engine oil. Ring out any excess oil.
  • Page 54: Spark Plug Maintenance

    MAINTENANCE AND CARE (CONTINUED) Spark Plug Maintenance The spark plug is important for proper engine operation. A good spark plug should be intact, free of deposits, and properly gapped. SPARK PLUG CONSULT MANUAL Improper maintenance may cause reduced fuel economy, BEFORE REMOVING misfires, trouble starting, or damage to the spark plug threads.
  • Page 55 Measure plug gap Measure the plug gap with a gauge. The gap should be 0.7-0.8 mm (0.028-0.031 in). Clean and re-gap If you are re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base and then re-gap the spark plug.
  • Page 56: Emptying The Gas Tank

    MAINTENANCE AND CARE (CONTINUED) Emptying the Gas Tank If you have been using gasoline in your generator; before storing your generator for extended periods of time you should drain your generator fuel tank of gasoline. CAUTION: Do not store fuel from one season to another. Gasoline sold at the pump today contains additives such as ethanol that even when stored properly may damage the fuel system components.
  • Page 57 Drain gas from the generator With a funnel underneath the fuel valve to catch the gas, turn the fuel valve to the “ON” position. Drain all the gas from the generator. Shut fuel valve off Turn the fuel valve to the “OFF” position. Replace fuel filter cup Reinstall the fuel filter cup.
  • Page 58: Cleaning The Fuel Filter Cup

    MAINTENANCE AND CARE (CONTINUED) Cleaning the fuel filter cup Shut fuel valve off Turn the fuel valve to the “OFF” position. Remove fuel filter cup Unscrew the fuel filter cup from the fuel valve using a wrench. Clean filter cup Clean the cup of all sediment using a rag or brush.
  • Page 59: Storage And Transportation

    Storage and Transportation CAUTION: Never place any type of storage cover on the generator while it is still hot. When transporting your generator: Empty the gas tank (see “Emptying the Gas Tank” in the “Maintenance” section). ● Disconnect the spark plug. ●...
  • Page 61: Troubleshooting

    TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator.
  • Page 62 TROUBLESHOOTING Mode Description Engine Switch is “Off” Set engine switch to “run” Fuel Valve is “Closed” Turn fuel valve to “open” Choke is open Close the choke Engine is out of fuel Add fuel Engine will not start Fuel is old or contaminated Change fuel Spark Plug is dirty Clean spark plug...
  • Page 63: Changing / Inspecting The Carbon Brushes

    Changing / Inspecting the Carbon Brushes The carbon brushes in conjunction with the AVR regulates power from the generator. The carbon brushes are wearable parts and should be inspected every 250 running hours. Remove generator cover Remove the 2 bolts of the generator cover then pull the cover off the generator.
  • Page 64 TROUBLESHOOTING (CONTINUED) Changing / Inspecting the Carbon Brushes (Cont.) Install new brush Install new carbon brush with bolt. Connect AVR wires Insert and connect the 2 wires from the AVR, be sure to connect + and – correctly. Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts.
  • Page 65: Changing / Inspecting The Avr

    Changing / Inspecting the AVR The carbon brushes in conjunction with the AVR regulates power from the generator. If the generator is overheated or overloaded, the AVR may be damaged and require replacement. Remove generator cover Remove the 2 bolts of the generator cover then pull the cover off the generator.
  • Page 66 TROUBLESHOOTING (CONTINUED) Changing / Inspecting the AVR (Continued) Disconnect wires from brush Remove the 2 wires from the AVR on the carbon brush. Install new AVR Install the new AVR with the 2 bolts. Reconnect wires to brush Insert and connect the 2 wires from the AVR, be sure to connect + and –...
  • Page 67 Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts.
  • Page 68 WIRING DIAGRAM...
  • Page 70 • •...
  • Page 71 • •...
  • Page 72 • •...
  • Page 73 • •...
  • Page 74 CUSTOMER SERVICE Duromax Power Equipment is committed to ensuring that our products perform when they need to. Our generators are your lifeline in the event of an emergency. Should you have any problems, please contact our customer service department: DUROMAX POWER EQUIPMENT...
  • Page 76 5800 Ontario Mills Parkway Ontario, CA 91764 United States 844-DUROMAX REV: XP10000E-07072020...

Table of Contents

Save PDF