Installation and Operation Manual BEKOKAT
3.6
Technical data
Technical data BEKOKAT
Name
Model
Medium
Connection
Minimum
permissible
pressure
Max.
Permissible
pressure
Differential
pressure
assembly unit
Operating pressure
Maximum volume flow rate at inlet
(ISO 1217) at operating pressure
Min. volume flow rate at the inlet
Permissible
compressed
temperature at inlet
Operating
temperature
compressed air
Minimum / Maximum Ambient
temperature
Supply Voltage
Nominal capacity
Current consumption
Temperature sensor
Safety valve
Weight
Width x Height x Depth
38 / 88
®
®
BEKOKAT
BEKOKAT
Compressed air
Fluid group 2 according to DGRL 2014/68/EU
Up to 100% saturated, free of liquid water or
condensate
Free of aggressive, corrosive, caustic, toxic,
flammable or combustion supporting materials
and substances
Cylindrical internal thread Rp 2 1/2 ", DN 65
In accordance to DIN EN 10226-1
operating
4 bar (g)
operating
11 bar (g)
of
the
<0.6 bar at 100% load
7 bar (g)
1200 m³/h
Relating to +20°C and 1 bar(a)
20% of the nominal volume flow = 240 m³ / h
air
+5°C ... +45°C
for
+35°C,
+5°C / +45°C
400 VAC / 3 Ph / PE / 50 Hz
14.1 kW
21.0 A
Thermocouple type "K" NiCr-Ni
Setting value 16 bar (g)
810
1650 mm x 2260 mm x 1050 mm
®
CC-1200
®
catalytic converter
1)
V01 / 11-043