Download Print this page

Troubleshooting - STEINEL XLED home 2 Quick Start Manual

Hide thumbs Also See for XLED home 2:

Advertisement

equipment no longer suitable for use must be col-
lected separately and recycled in an environmen-
tally compatible manner.
9. Warranty
7KLV67(,1(/SURGXFWKDVEHHQPDQXIDFWXUHGZLWK
XWPRVWFDUHWHVWHGIRUSURSHURSHUDWLRQDQGVDIHW\
DQGWKHQVXEMHFWHGWRUDQGRPVDPSOHLQVSHFWLRQ
6WHLQHOJXDUDQWHHVWKDWLWLVLQSHUIHFWFRQGLWLRQ
DQGSURSHUZRUNLQJRUGHU7KHZDUUDQW\SHULRGLV
\HDUVDQGVWDUWVRQWKHGDWHRIVDOHWRWKHFRQ
VXPHU:HZLOOUHPHG\GHIHFWVFDXVHGE\PDWHULDO
ƃDZVRUPDQXIDFWXULQJIDXOWV7KHZDUUDQW\ZLOOEH
PHWE\UHSDLURUUHSODFHPHQWRIGHIHFWLYHSDUWVDW
RXURZQGLVFUHWLRQ7KHZDUUDQW\VKDOOQRWFRYHU
GDPDJHWRZHDUSDUWVGDPDJHRUGHIHFWVFDXVHG
E\LPSURSHUWUHDWPHQWRUPDLQWHQDQFH)XUWKHU
FRQVHTXHQWLDOGDPDJHWRRWKHUREMHFWVVKDOOEH
H[FOXGHG&ODLPVXQGHUWKHZDUUDQW\ZLOORQO\EH
10. Technical specifications
XLED Home 2
Dimensions (H × W × D)
194 × 180 × 161
Output
14.8 W / 80 lm/W
Luminous flux / brightness
1184 lm
Weight
0.575 kg
Area illuminated
Front view
Side view
Mains current
75mA
Power factor
0.84
Additional switching capacity
max. 1000 W (resistive load, e.g. light bulbs)
max. 500 W (uncorrected, inductive, cos = 0.5,
e.g. fluorescent lamps)
max. 4 × 56 W / C ≤ 88 μF
E"ciency
80 lm/W
Colour temperature
4000 K (neutral white)
Colour rendering index
Ra ≥ 80
Supply voltage
230-240 ~V / 50/60 Hz
Sensor system
Passive infrared
Reach
max. 14 m
Angle of coverage
140°
Time setting
8 s - 35 min
Twilight setting
2 - 2000 lux
IP / protection class
IP44 / II
DFFHSWHGLIWKHXQLWLVVHQWIXOO\DVVHPEOHGDQG
ZHOOSDFNHGZLWKDEULHIGHVFULSWLRQRIWKHIDXOWD
UHFHLSWRULQYRLFHGDWHRISXUFKDVHDQGGHDOHUV
VWDPSWRWKHDSSURSULDWH6HUYLFH&HQWUH
Service:
2XU&XVWRPHU6HUYLFH'HSDUWPHQWZLOOUHSDLUIDXOWV
QRWFRYHUHGE\ZDUUDQW\RUDIWHUWKHZDUUDQW\SH
ULRG3OHDVHVHQGWKHSURGXFWZHOOSDFNHGWR\RXU
QHDUHVW6HUYLFH&HQWUH
5
Y E A R
MANUFACTURER'S
WARRANTY
XLED Home 2 XL
212 × 180 × 161
20 W / 80 lm/W
1608 lm
0.620 kg
283.1 cm
2
Front view
316.2 cm
113 cm
2
Side view
115 cm
97mA
0.86
– 14 –

11. Troubleshooting

Malfunction
Sensor-switched LED floodlight
without power
Sensor-switched LED floodlight
will not switch ON
Sensor-switched LED floodlight
will not switch OFF
Sensor-switched LED floodlight
keeps switching ON and OFF
Sensor-switched LED floodlight
switches ON when it should not
2
2
Cause
Remedy
Q Fuse faulty, not switched ON,
Q Replace fuse, turn ON mains
break in wiring
switch, check lead with voltage
tester
Q Short circuit
Q Check connections
Q Twilight setting in night mode
Q Readjust
during daytime operation
Q Mains power switch OFF
Q Switch ON
Q Fuse faulty
Q Fit new fuse, check connec-
tion if necessary
Q Detection zone not properly
Q Readjust
targeted
Q Continuous movement in the
Q Check zone and readjust if
detection zone
necessary or apply shroud
Q Animals moving in the detec-
Q Tilt sensor higher or apply
tion zone
specific shrouds; adjust
detection zone or fit shrouds
Q Wind is moving trees and
Q Change detection zone
bushes in the detection zone
Q Cars on the road are being
Q Change detection zone
detected
Q Sudden change in tempera-
Q Change detection zone,
ture caused by weather (wind,
mount in a di%erent place
rain, snow) or air discharged
from fans, open windows
Q Sensor-switched LED flood-
Q Fit sensor-switched LED flood-
light swaying (moving),
light to a firm surface
resulting, for example, from
gusts of wind or heavy
precipitation