Mitsubishi Electric Mr.SLIM PUZ-ZM35VKA-ET Service Manual page 57

Split-type, heat pump air conditioners

Advertisement

Phone Calls From Customers
Something
3 Air blows out for a while after
is wrong
HEAT operation is stopped.
with the
blower.....
Something
1 The airflow direction is
is wrong
changed during COOL opera-
with the
tion.
airflow
direction....
2 The airflow direction is
changed during HEAT opera-
tion.
(The airflow direction cannot
be set by remote controller.)
3 The airflow direction does not
change.
(Up/down vane, left/right louver)
The air conditioner starts operating even
though any buttons on the remote controller
are not pressed.
The air conditioner stops even though any
buttons on the remote controller are not
pressed.
OCH653C
How to Respond
3 This is not a malfunction.
The blower is operating just for cooling down the
heated-up air conditioner. This will be done within
1 minute.
This control is conducted only when the HEAT
operation is stopped with the electric heater ON.
1 If the up/down vane is set to downward in COOL
operation, it will be automatically set to horizontal
blow by the microprocessor in order to prevent
water from dropping down.
"1 Hr." will be displayed on the remote controller
if the up/down vane is set to downward with the
fan speed set to be less than "LOW".
2 In HEAT operation, the up/down vane is auto-
matically controlled according to the temperature
of the indoor unit's heat exchanger.
In the following cases written below, the up/down
vane will be set to horizontal blow, and the set-
ting cannot be changed by remote controller.
1) At the beginning of the HEAT operation
2) While the outdoor unit is being stopped by
thermostat or when the outdoor unit gets start-
ed to operate.
3) During DEFROST operation
The airflow direction will be back to the setting
of remote controller when the above situations
are released.
3 1) Check if the vane is set to a fixed position.
(Check if the vane motor connector is removed.)
2) Check if the air conditioner has a function for
switching the air direction.
3) If the air conditioner does not have that func-
tion, "NOT AVAILABLE" will be displayed on
the remote controller when "AIR DIRECTION"
or "LOUVER" button is pressed.
1 Check if you set ON/OFF timer.
The air conditioner starts operating at the time
designated if ON timer has been set before.
2 Check if any operations are ordered by distant
control system or the central remote controller.
While "CENTRALLY CONTROLLED INDICATOR"
is displayed on the remote controller, the air con-
ditioner is under the control of external directive.
3 Check if power is recovered from power failure
(black out).
The units will automatically start operating when
power is recovered after power failure (black out)
occurs. This function is called "auto recovery fea-
ture from power ".
1 Check if you set ON/OFF timer.
The air conditioner stops operating at the time
designated if OFF timer has been set before.
2 Check if any operations are ordered by distant
control system or the central remote controller.
While "CENTRALLY CONTROLLED INDICATOR"
is displayed on the remote controller, the air con-
ditioner is under the control of external directive.
57
Note
However, this control is
also applied to the models
which has no electric
heater.
-
"STANDBY" will be dis-
played on the remote con-
troller in the case of 1 and
2. "DEFROSTING" will be
displayed on the screen in
the case of 3.
-
-
There might be a case
that "CENTRALLY
CONTROLLED
INDICATOR" will not be
displayed.
-
There might be a case
that "CENTRALLY
CONTROLLED
INDICATOR" will not be
displayed.