LSIS iS7 Series Firmware Flash Procedure

LSIS iS7 Series Firmware Flash Procedure

Vfd

Advertisement

Purpose
This document provides the step by step procedure for flashing firmware on an LSIS iS7 VFD using the Smart Copier.
This procedure should be followed whenever an application demands custom application specific firmware or an update to
the latest factory firmware.
For questions or assistance with this procedure please contact LSIS Technical Support.
Phone: 800-891-2941
Email: tech_support.us@lsis.com

1. Necessary Items

Smart Copier (the below items are included with purchase) LSIS Order Code: 64090112
o
4 qty AA Batteries
o
SD Card
Smart Copier Gender (order both this and the Smart Copier!) LSIS Order Code: 64090124
o
10-pin cable
o
Gender Connectors for S100, H100, and iS7
Computer with SD card slot
Flash File
LSIS iS7 VFD

2. Preparing the Firmware File

a. Request the needed firmware file from LSIS
Technical Support.
b. The Smart Copier uses a .scf file
type though the .scf is not listed in
Windows explorer. Verify the
correct file type by right-clicking the file and
selecting "properties." The file type .scf is listed.
See Figure 1.
c. Insert the SD card which came with the smart
copier into the PC.
d. Create a new folder on the SC card titles
"firmwares".
e. Drag and Drop or Copy/Paste the firmware file
into the "firmwares" folder on the SD Card.
f.
Remove the SD Card from the PC and insert into
the SD card slot on the right side of the Smart
Copier. See Figure 2.
LSIS VFD Firmware Flash Procedure
Figure 2
iS7
.scf file type is
necessary for the
Smart Copier
1
No file extension
Figure 1
LSIS iS7 Firmware Flash Procedure
Rev A_12-13-2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iS7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for LSIS iS7 Series

  • Page 1 LSIS VFD Firmware Flash Procedure Purpose This document provides the step by step procedure for flashing firmware on an LSIS iS7 VFD using the Smart Copier. This procedure should be followed whenever an application demands custom application specific firmware or an update to the latest factory firmware.
  • Page 2 LSIS VFD Firmware Flash Procedure 3. Connecting to the VFD a. Install the provided AA batteries into the battery compartment on the back of the Smart Copier. b. Connect the 10-pin ribbon cable to the top of the Smart Copier c.
  • Page 3 LSIS VFD Firmware Flash Procedure g. Gain access to the flash port by removing the keypad and the front cover. See Figure 5. Figure 5 LSIS iS7 Firmware Flash Procedure Rev A_12-13-2016...
  • Page 4 LSIS VFD Firmware Flash Procedure h. Connect the “iS7 Main” Gender to the VFD flash port. Take note that the Gender connection direction and placement must be correct. This is printed on the Gender board and also explained in Figure 6 below.
  • Page 5 LSIS VFD Firmware Flash Procedure 5. Setting the VFDs kW After flashing an iS7 VFD the kW capacity must be set. Follow the below steps. a. Hold the ESC button b. While holding the ESC button… 1. press the UP button 2.

This manual is also suitable for:

Sv1850is7-4sodSv0750is7-4nodSv3750is7-4so

Table of Contents