Settings before delivery from factory
Function
Low-speed lifting
Low-speed lowering
High-speed lifting
Frequency
High-speed lowering
setting
No-load high-speed
lifting
No-load high-speed
lowering
Upper-limit stop point
Upper-limit
Operation
speed-reduction point
limit
Lower-limit
position
speed-reduction point
setting
Lower-limit stop point
No-load high-speed setting
Overload stoppage function setting
Conditions factory-set
before delivery
9 Hz
6 Hz
60 Hz
90 Hz
10 mm below the
LS lever
150 mm below the
Adjusted to any point in
upper-limit stop point
the range of lift
150 mm above the
Fin adjustment setting
lower-limit stop point
range: 1 to 9999
Position where 2 turns
of rope are
left wound
OFF
OFF
-17-
Setting range
Remarks
6 - 60 Hz
-
The limit switches can
be respectively turned
on and off.
Butch adjustment of
all points is possible.
ON/OFF
ON/OFF
-
-
-
-