Sears CRAFTSMAN 390.260293 Owner's Manual
Sears CRAFTSMAN 390.260293 Owner's Manual

Sears CRAFTSMAN 390.260293 Owner's Manual

Portable 1/2 h.p. utility/sprinkler pump

Advertisement

OWNER'S
MANUAL
MODEL NO.
390.260293
CAUTION:
Read and Follow
All Safety Rules and
Operating Instructions
Before First Use of
This Product.
Save This Manual For
Future Reference.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A.
PORTABLE 1/2 H.P.
UTILITY/SPRINKLER PUMP
• Installation
• Operation
• Maintenance
• Repair Parts
®
F642-0201
Form No.
(Rev. 4/20/04)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRAFTSMAN 390.260293 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sears CRAFTSMAN 390.260293

  • Page 1 Operating Instructions Before First Use of • Installation This Product. • Operation Save This Manual For • Maintenance Future Reference. • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN U.S.A. F642-0201 Form No. (Rev. 4/20/04)
  • Page 2 FULL ONE YEAR WARRANTY ON CRAFTSMAN ® 1/2-HP UTILITY/SPRINKLER PUMP For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or workmanship. LIMITATION OF LIABILITY SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.
  • Page 3: Installation

    INSTALLATION Pumping From Lakes, Streams, and Ponds Boosting City Water Pressure Hazardous pressure. When using garden Locate pump as near as possible (vertically) to water source, to keep suction lift (distance from water to pump) as low as hose as a discharge line, do not run pump with possible.
  • Page 4: Operation

    OPERATION PRIMING/OPERATION LUBRICATION NOTICE: Do not run pump dry. Running pump without Motor is lubricated at factory for life of bearings. Pump seal water can damage impeller and may damage seal, causing is water cooled and self lubricating. leaking or flooding, and will void warranty. PUMP SERVICE All suction connections must be airtight.
  • Page 5 ELECTRICAL Plug pump into 115 Volt, 60 Cycle outlet only. Pump is Risk of dangerous or fatal electric equipped with 3-wire, grounded, cord and plug. Do not shock. Unplug pump before servicing it. modify or remove plug. Plug in to properly grounded, Hazardous Do not handle pump or attempt to work voltage...
  • Page 6 PUMP DISASSEMBLY AND SEAL REPLACEMENT Step 1 Step 2 Risk of electric shock. Unplug pump before working on it. Make sure that you do not scratch, nick, or crack new seal. Do not scratch or gouge pump shaft. Make sure seal faces are clean when installing new seal.
  • Page 7: Repair Parts

    REPAIR PARTS To order parts, call: Sears Product Service, 1-800-366-7278 2389 0496 Part Number Part Description Qty. 101P3410 Pump Body 111P0710 Drain/Priming Port O-Ring 102P1030 Drain/Fill Cap 111P0370 Hose Adapter O-Ring 101P3460 Garden Hose Adapter 111P0480 Venturi O-Ring 102P2840 Venturi/Diffuser...
  • Page 8 Maintenance Agreement or to inquire about an existing Agreement call 9 am - 5 pm, Monday-Saturday • Product Type 1-800-827-6655 • Model Number • Part Number • Part Description REPAIR SERVICES America's Repair Specialists Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.