Sears 390.260291 Owner's Manual
Sears 390.260291 Owner's Manual

Sears 390.260291 Owner's Manual

Portable 1/2 h.p. utility/sprinkler pump

Advertisement

OWNER'S
MANUAL
MODEL NO.
390.260291
CAUTION:
Read and Follow
All Safety Rules and
Operating Instructions
Before First Use of
This Product.
Save This Manual For
Future Reference.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A.
PORTABLE 1/2 H.P.
UTILITY/SPRINKLER
PUMP
• Installation
• Operation
• Maintenance
• Repair Parts
F642-9709
Form No.
(4/23/97)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 390.260291 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sears 390.260291

  • Page 1 PUMP Operating Instructions Before First Use of • Installation This Product. • Operation Save This Manual For • Maintenance Future Reference. • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN U.S.A. F642-9709 Form No. (4/23/97)
  • Page 2 *Lake Chemical Co., Chicago, Illinois FULL ONE YEAR WARRANTY For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in materials or work- manship. This warranty does not cover repairs on replacement parts necessary because of abuse or negligence including failure to install, adjust and operate this pump according to the instructions in the owner’s manual.
  • Page 3: Installation

    INSTALLATION Pumping From Lakes, Streams, and Ponds Boosting City Water Pressure Hazardous pressure. When using garden Locate pump as near as possible (vertically) to water source, to keep suction lift (distance from water to pump) as low as hose as a discharge line, do not run pump with possible.
  • Page 4: Operation

    OPERATION PRIMING/OPERATION LUBRICATION NOTICE: Do not run pump dry. Running pump without Motor is lubricated at factory for life of bearings. Pump seal water can damage impeller and may damage seal, causing is water cooled and self lubricating. leaking or flooding, and will void warranty. PUMP SERVICE All suction connections must be airtight.
  • Page 5 ELECTRICAL equipped with 3-wire, grounded, cord and plug. Do not Risk of dangerous or fatal electric modify or remove plug. Plug in to properly grounded, shock. Unplug pump before servicing it. grounding type outlet only. Make sure pump circuit meets Hazardous Do not handle pump or attempt to work voltage...
  • Page 6 PUMP DISASSEMBLY AND SEAL REPLACEMENT Step 1 Step 2 Risk of electric shock. Unplug pump before working on it. Make sure that you do not scratch, nick, or crack new seal. Do not scratch or gouge pump shaft. Make sure seal faces are clean when installing new seal.
  • Page 7: Repair Parts

    REPAIR PARTS To order parts, call: Sears Product Service, 1-800-366-7278 2389 0496 Part Number Part Description Qty. 742S0130 Pump Body 111P0710 Drain/Priming Port O-Ring 102P1030 Drain/Fill Cap 111P0790 Hose Adapter O-Ring 742S0590 Garden Hose Adapter 111P0480 Venturi O-Ring 742S0140 Venturi/Diffuser...
  • Page 8 Maintenance Agreement or to inquire about an existing Agreement call 9 am - 5 pm, Monday-Saturday • Product Type 1-800-827-6655 • Model Number • Part Number • Part Description REPAIR SERVICES America's Repair Specialists Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.

Table of Contents