Supplement; Technical Data - Vega VEGAPOINT 21 Operating Instructions Manual

Capacitive level switch, transistor (npn/pnp)
Table of Contents

Advertisement

13 Supplement

13 Supplement

13.1 Technical data

Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Sensor tip
Ʋ Device seal - Standard version
Ʋ Device seal - Hygienic version
Ʋ Process seal
Ʋ Process fittings
Materials, non-wetted parts
Ʋ Housing
Ʋ Device seal - Hygienic design AC and
AM
7)
Ʋ Seal plug
Weight
General data
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A)
Ʋ Pipe thread, conical (ASME B1.20.1)
Ʋ Metric fine thread, cylindrical
Threaded and hygienic adapter
Ʋ Standard hygienic adapter
Ʋ Clamp
Ʋ Collar socket DIN 11851, PN40
Max. torque - process fitting
Ʋ Thread G½, ½ NPT
Ʋ Thread G¾, ¾ NPT
Ʋ Thread G1, 1 NPT
Ʋ Hygienic adapter
Surface quality
Measurement accuracy
Hysteresis
not in contact with the medium
7)
42
PEEK, polished
FKM
EPDM
Klingersil C-4400
316L
316L and plastic (Valox and polycarbonate)
EPDM
NBR
approx. 250 g (0.55 lbs)
G½, G¾, G1
½ NPT, ¾ NPT, 1 NPT
M 24 x 1.5
G½, G1
1", 1½", 2"
DN 25, DN 32, DN 40
50 Nm (37 lbf ft)
75 Nm (55 lbf ft)
100 Nm (73 lbf ft)
20 Nm (15 lbf ft)
R
< 0.76 µm (3.00
in)
-5
a
approx. 1 mm (0.04 in)
VEGAPOINT 21 • Transistor (NPN/PNP)