Symbols used Document ID This symbol on the front page of this instruction refers to the Docu- ment ID. By entering the Document ID on www.vega.com you will reach the document download. Information, note, tip: This symbol indicates helpful additional infor- mation and tips for successful work.
During work on and with the device, the required personal protective equipment must always be worn. Appropriate use The VEGAPOINT 23 is a sensor for point level detection. You can find detailed information about the area of application in chapter " Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions.
A Class 2 power supply unit has to be used for the installation in the USA and Canada. Safety instructions for Ex areas For Ex applications, only devices with corresponding Ex approval may be used. Observe the Ex-specific safety instructions. These are an integral part of the operating instructions and are enclosed with every device with Ex approval. VEGAPOINT 23 • Transistor (PNP/NPN)
This operating instructions manual applies to the following instrument Scope of this operating instructions versions: • Hardware version from 1.0.0 • Software version from 1.3.0 Constituent parts The VEGAPOINT 23 consists of the components: • Housing with integrated electronics • Process fitting • Plug VEGAPOINT 23 • Transistor (PNP/NPN)
Page 8
3 Product description Fig. 1: VEGAPOINT 23 LED illuminated ring Instrument housing 3 Process fitting Sensor Extension tube Plug connection Type label You will find the type plate on the sensor housing. The type label contains the most important data for identification and use of the instrument. VEGAPOINT 23 • Transistor (PNP/NPN)
Principle of operation Application area The VEGAPOINT 23 is a capacitive point level sensor for point level detection It is designed for industrial use in all areas of process technology and can be used in water-based liquids.
3 Product description Typical applications are overfill and dry run protection. With a the small sensor unit, VEGAPOINT 23 can be also mounted e.g. in thin pipelines. The sensor allows use in vessels, tanks and pipes. Thanks to its simple and robust measuring system, VEGAPOINT 23 is virtu- ally unaffected by the chemical and physical properties of the liquid. It also works under difficult measuring conditions such as turbulence, air bubbles, strong external vibrations or changing media.
Unless otherwise indicated, the packages must be stored only under the following conditions: • Not in the open • Dry and dust free • Not exposed to corrosive media • Protected against solar radiation • Avoiding mechanical shock and vibration VEGAPOINT 23 • Transistor (PNP/NPN)
Accessories The instructions for the listed accessories can be found in the down- load area on our homepage. Threaded and hygienic Various threaded and hygienic sockets are available for devices with socket threaded version. You can find further information in the "Technical data" VEGAPOINT 23 • Transistor (PNP/NPN)
Chemical properties of the medium • Abrasion and mechanical influences Switching point The VEGAPOINT 23 can be mounted in any position. The instrument must be mounted in such a way that the sensor is at the height of the requested switching point. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 14
Handling The level switch is a measuring device for stationary screw mounting and must be treated accordingly. Damage to the measuring tip will destroy the instrument. Use the hexagon above the thread for screwing in. VEGAPOINT 23 • Transistor (PNP/NPN)
For this reason, do not use an overly long extension tube for VEGAPOINT 23, but check if you can mount a short level switch on the side of the vessel in horizontal position.
Cable diameter 4.5 … 7 mm, protection IP65. 1. Loosen the screw on the rear of the plug connector 2. Remove the plug connector and seal from VEGAPOINT 23 3. Remove the plug insert from the plug housing 4.
Page 19
8 Profile seal 7. Snap the plug insert into the plug housing and insert the sensor seal 8. Plug the plug insert with seal to VEGAPOINT 23 and tighten the screw Valve plug ISO 4400 with For this plug version you can use standard cable with round wire IDC method of termina- cross-section.
Page 20
Fig. 11: Connection to the screw terminals Cable gland Cover Plug housing Plug insert Plug seal 8. Snap the plug insert into the plug housing and insert the sensor seal Information: Note the correct arrangement, see illustration VEGAPOINT 23 • Transistor (PNP/NPN)
9. Tighten the screws on the strain relief and cable entry 10. Hook in the cover and push onto the plug connection, tighten cover screw 11. Plug the plug insert with seal to VEGAPOINT 23 and tighten the screw Wiring plan For connection to binary inputs of a PLC.
If this document is lost, the emergency device code can be retrieved from your personal contact person after legitimation. The storage and transmission of the device codes is always encrypt- ed (SHA 256 algorithm). VEGAPOINT 23 • Transistor (PNP/NPN)
" PINs and Codes". This greatly simplifies the use of additional adjust- ment tools, as all Bluetooth access and device codes are automati- cally synchronized when connected to the " myVEGA" account VEGAPOINT 23 • Transistor (PNP/NPN)
There are several ways to operate the device. The Bluetooth version (optional) of the instrument enables a wireless connection to standard adjustment units. This can be smartphones/ Default setting Default setting Default setting Output 1 VEGAPOINT 23 • Transistor (PNP/NPN)
Page 25
100 % Signalling NAMUR NE 107 Fault Switching output Yellow Operating status Green Access protection Bluetooth access code See supplementary sheet "PINs and Codes". Protection of the parameterization Deactivated Reset Units Temperature unit °C Only for "User-defined" application VEGAPOINT 23 • Transistor (PNP/NPN)
Standard (level detection) • Uncovered • Covered • With buildup User-defined If you have selected the application User-defined you can adjust the switching states with the original medium or with the actual covering state. Only DTM adjustment VEGAPOINT 23 • Transistor (PNP/NPN)
Page 27
Only when the reset point (RP) is reached does the output switch back. If the measured variable moves between switching and reset point, the state of the output does not change. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 28
Window High (FH) and Window Low (FL). If the measured variable leaves the window, the output returns to its previous state. If the measured variable moves within the window, the state of the output does not change. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 29
The setting is a degree for the sensitivity of the sensor tip. Switching delay (DS1) The switching delay (DS) extends the reaction time until the sensor is switched over when the sensor tip is covered. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 30
Bluetooth access code With the function " Bluetooth access code" you can release the Bluetooth data connection. To activate the function, you must enter the six-digit access code. You can find the Bluetooth access code in the " PINs and Codes" sheet of the shipping documentation. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 31
The value is retained in the event of a reset. Peak value indicator In this menu item you can retrieve the pointer function of the device. For each pointer there is a max. and a min. value. In addition, the current value is displayed. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 32
Without manual deactivation, the sensor terminates the simulation automatically after 60 minutes. Impedance curve In this menu item you can see the impedance curve of the device. The impedance curve gives information about the switching behav- iour of the sensor. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 33
Hardware version • Software version • Factory calibration date • Device Revision Sensor characteristics In this menu item you can retrieve the sensor features of the device. • Order texts • Instrument version • Electronics VEGAPOINT 23 • Transistor (PNP/NPN)
• Operating system: Android 5.1 or newer • Bluetooth 4.0 LE or newer Download the VEGA Tools app from the " Apple App Store", " Goog- le Play Store" or " Baidu Store" to your smartphone or tablet. Connecting Connecting Start the adjustment app and select the function "...
The sensor adjustment menu is divided into two halves: On the left you'll find the navigation section with the menus " Setup", " Diagnosis" and others. The selected menu item, recognisable by the colour change, is dis- played in the right half. Fig. 16: Example of an app view - Setup VEGAPOINT 23 • Transistor (PNP/NPN)
Enter Bluetooth access For authentication, enter in the next menu window the 6-digit code Bluetooth access code: Fig. 17: Enter Bluetooth access code VEGAPOINT 23 • Transistor (PNP/NPN)
The sensor adjustment menu is divided into two halves: On the left you'll find the navigation section with the menus " Setup", " Display", " Diagnosis" and others. The selected menu item, recognisable by the colour change, is dis- played in the right half. Fig. 18: Example of a DTM view - Setup VEGAPOINT 23 • Transistor (PNP/NPN)
24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is also available outside normal working hours, seven days a week around the clock.
2 Out of specification - yellow Function check - orange Maintenance required - blue Failure: Due to a malfunction in the instrument, a fault message is output. This status message is always active. It cannot be deactivated by the user. VEGAPOINT 23 • Transistor (PNP/NPN)
Page 40
A simulation is active Finish simulation Simulation active Wait for the automatic end after 60 mins. Out of specification Code Cause Rectification Text message S600 Temperature of the electronics in the Check ambient temperature non-specified range Impermissible electronics Insulate electronics temperature VEGAPOINT 23 • Transistor (PNP/NPN)
Clean the instrument and pack it damage-proof • Attach the completed form and, if need be, also a safety data sheet outside on the packaging • Ask the agency serving you to get the address for the return ship- ment. You can find the agency on our homepage. VEGAPOINT 23 • Transistor (PNP/NPN)
11.2 Disposal The device is made of recyclable materials. For this reason, it should be disposed of by a specialist recycling company. Observe the ap- plicable national regulations. VEGAPOINT 23 • Transistor (PNP/NPN)
That is why we have introduced an environment management system with the goal of continuously improving company environmental pro- tection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observ- ing the environmental instructions in chapters " Packaging, transport and Lagestoragerung", " Disposal" of these operating instructions. VEGAPOINT 23 • Transistor (PNP/NPN)
Ʋ Metric fine thread, cylindrical M 24 x 1.5 Ʋ Clamp 1", 1½", 2" Ʋ Collar socket DIN 11851, PN40 DN 25, DN 40, DN 50 Max. lateral load 60 Nm (44 lbf ft) not in contact with the medium VEGAPOINT 23 • Transistor (PNP/NPN)
Page 45
(9.84 in) Ʋ For tube length > 250 mm (9.84 in) -40 … +80 °C (-40 … +176 °F) SIP process temperature (SIP = Sterilization in place) Vapour stratification up to 1 h +135 °C (+275 F) Dielectric constant ≥ 1.5 VEGAPOINT 23 • Transistor (PNP/NPN)
Page 46
Ʋ Wire diameter 1.6 … 2 mm² (0.06 … 0.08 in²) Ʋ Outer cable diameter 5.5 … 8 mm (0.22 … 0.31 in) Ʋ Connection frequency 10 x (on the same cross-section) Depending on the local conditions VEGAPOINT 23 • Transistor (PNP/NPN)
Page 47
Plug according to ISO 4400 with IP67 NEMA 4X IDC method of termination ISO 4400 plug with hinged cover IP65 NEMA 4X Altitude above sea level up to 5000 m (16404 ft) Overvoltage category Protection class Pollution degree VEGAPOINT 23 • Transistor (PNP/NPN)
(0.71") (0.71") Fig. 20: VEGAPOINT 23, standard version - thread, with valve plugs acc. to ISO 4400 Thread ½ NPT, ¾ NPT, 1 NPT with ISO 4400 valve plug Thread G½, G¾, G1 (DIN ISO 228/1) with ISO 4400 valve plug with IDC method of termination Thread G½, G¾, G1, ¾...
Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.
Need help?
Do you have a question about the VEGAPOINT 23 and is the answer not in the manual?
Questions and answers