8. troUBleshootiNG

FAUlt
1A) Pressure drop in the tank
1B) Pressure drop in the tank
1C) Pressure drop in the tank
2) Pressure switch valve leaks when
compressor is idle
3) Air leaks from tank body or tank welds
4A) motor stops and will not restart
4B) Motor stops and will not restart
5) Compressor stops and does not restart
6A) Compressor does not stop at max. pressure
6B) Compressor does not stop at max. pressure
7) Compressor noisy with metallic knock
8) Excessive moisture in discharged air
4 pc Air AccessorY Kit
SUPPLIED WITH MODEL NO:
9. sprAY GUN sAFetY
WArNiNG! disconnect the spray gun from the air supply before changing accessories, servicing or performing any maintenance.
Familiarise yourself with this products application and limitations, as well as the specific potential hazards peculiar to the spray gun.
9
Paint cup remains pressurised after gun is disconnected from air line.
do Not pull the trigger, but release the pressure by gently opening cup.
8
maintain the spray gun in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use recommended parts only. Non authorised parts may be dangerous and will invalidate the
9
warranty.
locate the spray gun in an adequate working area for its function, keep area clean and tidy and free from unrelated materials, and
9
ensure there is adequate ventilation and lighting.
Keep the spray gun clean for best and safest performance.
9
Wear approved respiratory protection and safety eye goggles.
9
Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and tie back long hair.
9
Keep children and unauthorised persons away from the working area.
9
Avoid unintentional operation.
9
do Not point spray gun at yourself, at other persons or animals.
8
do Not carry the by the air hose, or pull the hose from the air supply.
8
do Not use the spray gun for any purpose other than for which it is designed.
8
do Not allow untrained persons to operate the spray gun.
8
do Not get the spray gun wet or use in damp or wet locations or areas where there is condensation.
8
do Not operate gun if any parts are missing or damaged as this may cause failure or personal injury.
8
do Not direct air from the air hose at yourself or others.
8
When not in use switch the spray gun off, and disconnect from the air supply.
9
10. tYre iNFlAtor sAFetY
disconnect the gauge from the air supply before changing accessories, servicing or performing any maintenance.
9
maintain the gauge in good condition (use an authorised service agent), and keep the gauge clean for best and safest performance.
9
Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate
9
the warranty.
locate gauge in a suitable work area, keep area clean and tidy and free from unrelated materials and ensure there is adequate lighting.
9
Keep children and unauthorised persons away from the work area.
9
do Not direct gauge outlet at yourself or at other persons or animals.
8
do Not carry by the hose, or yank the hose from the air supply.
8
do Not use the gauge for a task which it is not designed to perform.
8
do Not operate the gauge when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
do Not operate gauge if parts are missing or the gauge is damaged, as this may cause failure and/or personal injury.
8
© Jack Sealey limited
cAUse
Air leaks at connections
Air leaks from safety valve
Air leaks from cylinder head gasket
non-return valve seal defective
Internal corrosion caused by infrequent tank
draining or non permitted modifications to tank
Thermal cut out has operated
Supply fuse has tripped
motor failure
Pressure switch fault
Filter clogged
Head gasket or valve fault
Bearing or piston damage
High humidity environment
sAc5020epK.v2
Original Language Version
remedY
Run compressor to max. pressure, switch off
Brush soap solution over connections and look for
bubbles. Tighten connections showing leaks
If problem persists contact Authorised Service Agent
operate the safety valve manually by pulling on the
ring. If valve continues to leak when in the closed
position it should be replaced
Check tightness of head bolts. If leak continues
contact Authorised Service Agent
Empty the air tank. Referring to fig.6, remove the
non-return valve cap (3), spring (2) and seal (1)
Clean the seal and its seat, or if necessary replace
the seal
Tank could rupture or explode. Cannot be repaired
discoNtiNUe Use immediAtelY
Allow unit to cool for 30 minutes, then press reset
see fig.7.
Reset fuse and restart unit. If repeated tripping
occurs replace the check valve or contact
authorised service agent
Contact Authorised Service Agent
Contact Authorised Service Agent
Replace filter element.
Contact Authorised Service Agent
Contact Authorised Service Agent
drain tank after each use
SAC5020E.V3, SAC5020EPK.V2 Issue 1
13/06/19