Page 1
AFTER INSTALLATION THE END USER SHOULD KEEP THIS GUIDE FOR FUTURE REFERENCE DO NOT THROW AWAY FILTERLESS INFINITY FAN INSTALLATION GUIDE FOR ENGINEER / INSTALLER 230V - IPX4 SELV - IPX5...
Page 2
Safety Read and understand these instructions before beginning installation. The unit should be installed by a competent person. Check there is space to fit the unit in your chosen location. As standard it can be installed using 100mm or 125mm inside diameter duct.
Page 3
If the mains cable is damaged, it must be replaced by EnviroVent, an authorized service agent, or a similarly qualified person in order to avoid a hazard.
Page 4
Diagrams Duct Adaptor Rear Carcass Central Cartridge Impeller Front Cover 195mm 169mm 124mm SHOULD YOU ENCOUNTER ANY PROBLEMS 01423 859 395 INSTALLING THIS UNIT, CALL US ON: Filterless Infinity Fan...
Wiring Diagrams 230V 220V - 240V Local 50/60Hz Isolator Mains Supply Connect the local isolator to the Mains as part of the fixed wiring. Connect the N and L connectors of the fan power cable to the local isolator. SELV 220V - 240V Local SELV Power...
Page 6
About the Product Function The EnviroVent Filterless Infinity Fan has been developed to improve indoor air quality, reduce humidity levels in kitchens and bathrooms and resolve condensation and mould problems. It is designed to operate continuously for up to 7 years without a major service.
Installation ISOLATE THE MAINS SUPPLY BEFORE BEGINNING THE INSTALLATION 1. Loosen the two screws on the bottom of the unit, leave the screws in place and remove the front cover. 2. Pull the central cartridge out from inside the rear carcass. 3.
Page 8
5. Insert the rear carcass into the wall duct. 6. Fix to the wall using four of the labelled fixing holes and the four screws and wall plugs provided. 7. If using a backdraught shutter, insert it fully. The disc must open towards the outside of the property.
Page 9
9. Reconnect the green power connector to the unit. 10. Insert the central cartridge into the rear carcass. Do not trap any of the cables. Fix in place using the four supplied screws. 11. To change unit settings, adjust switches 1 and 2 on the central cartridge.
Page 10
12. Now apply the adhesive foam pad over the switches. Not using this will void the warranty and IP rating. 13. Ensure the impeller is fitted correctly, the two clips should both be engaged. 14. Replace the front cover ensuring the pullcord sits into the slot. Then tighten the two screws.
Performance Checklist • Is there power being supplied to the unit? • Are all internal electrical connectors attached or have any been disconnected? • Has the electronic circuit board been removed for any reason? • Is the central cartridge correctly seated in the rear carcass with no stray wires obstructing it? •...
Page 12
Cleaning ISOLATE THE UNIT FROM THE MAINS SUPPLY BEFORE CLEANING 1. Remove the front cover. 2. Push the impeller clips towards the centre, then pull the impeller out. 3. Clean the front cover and impeller in warm soapy water and allow to dry. Use a damp cloth to clean any other parts of the unit.
Airflow Performance Power Setting Duty (l/s) Bathroom on Trickle Bathroom on Boost Kitchen on Trickle Kitchen on Boost Energy Usage Power Hours Run Energy Cost Total Energy Cost Setting Per Day p/a (£) p/a (£) Bathroom 1.20 on Trickle 1.97 Bathroom 0.77 on Boost...
Product Variants Wireless Remote Control To pair additional remote-control switches: When the button on the remote control is pressed, the unit will 1. Turn the unit off at the isolation extract at the maximum extraction point. rate for up to 15 minutes then return 2.
The EnviroVent Filterless Infinity Fan is covered by a full 7-year warranty which will benefit the occupier over many years. There is no requirement for maintenance within the first 7-year period other than general cleaning.
Page 16
Your feedback is important to us as we strive to improve our and improvement EnviroVent reserves the products, services, and overall customer experience. Please email right to alter products specification and us to help us serve you better: feedback@envirovent.com appearance without notice.