Envirovent SILENT 100 Instruction Leaflet

Envirovent SILENT 100 Instruction Leaflet

Sxial extractor fans
Hide thumbs Also See for SILENT 100:

Advertisement

SILENT
Instruction leaflet

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SILENT 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Envirovent SILENT 100

  • Page 1 SILENT Instruction leaflet...
  • Page 3 Fig.1a Fig.1b...
  • Page 4 Fig.2 Fig.3 Fig.4...
  • Page 5 L N Ls Fig.5 L N Ls Fig.6 T (min) T (min) SILENT IT SILENT T Fig.7 SILENT PIR...
  • Page 6 L N Ls Fig.8 Fig.9 Fig.10...
  • Page 7 Fig.1 1 SILENT SILENT 100 SILENT 125 & 150 MODEL ØF SILENT 100 109,3 84,6 98,9 SILENT 125 SILENT 150 113,5...
  • Page 8 SILENT axial extractor fans Working ambient Please read this instruction booklet temperature carefully before installing or starting up product. contains important equipment should not be information on personal and user safety measures to be followed whilst installing, exceeded. Typically, this using and carrying out maintenance work falls within -5°C to +40°C, on the equipment.
  • Page 9 - SILENT-125: 125 to 132 mm. been given supervision or - SILENT-150: 160 to 158 mm. instruction concerning use If using the EnviroVent high rise wall kit, of the appliance in a safe please refer to kit for core drill size way and understand the...
  • Page 10 Electrical connection - To reduce the “run on” time, turn The SILENT is an extractor fan designed anticlockwise (min. 1 minute). for a single-phase supply, with voltage - To increase the “run on” time, turn and frequency as indicated on the rating clockwise (max: 30 minutes).
  • Page 11 - Switch 1: “Interval” function selection level. The extractor will stop automatically (yes or no) when the humidity drops below the selected level (-5% or +10%) and after the selected period set on the over-run timer. "Interval” functions: This function is useful when the extract - Switches 2 and 3: Interval time settings fan is installed in very wet (near the sea) between 4, 8, 12 and 24 hours...
  • Page 12 Automatic operation with external switch SILENT-100 PIR to override the extractor: (This version is only available as The extractor is connected to the main SILENT-100) supply with three wires. Models provided with a PIR detector. The Operation previous “Automatic unit starts automatically when...
  • Page 13 Thank you for choosing EnviroVent. If handler of this type of waste product. you experience any problems, please call The fan is mainly made of steel, copper our dedicated Technical Team on 0345 and plastic.
  • Page 14 Supply Only If your fan has been supplied by EnviroVent and installed by a third party, it is covered by a parts only warranty. If you detect a fault and the product has been installed in accordance to the fitting/wiring instructions, relevant...
  • Page 16 EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info@envirovent.com www.envirovent.com Ref. 9023065401...