Summary of Contents for Keysight M9384B

  • Page 1 Startup Guide Keysight M9384B VXG Microwave Signal Generator...
  • Page 2 CONTROLLERS, MODULES, ETC.) Keysight Technologies, Ground Floor specifically in writing elsewhere in the PERFORMANCE, SAFETY, OR EULA. Keysight shall be under no and Second Floor, CP-11 Sector-8, REGULATORY COMPLIANCE, UNLESS obligation to update, revise or otherwise IMT Manesar – 122051 Gurgaon, SPECIFICALLY STATED.
  • Page 3 When connecting sources to switching discomfort or burns if touched. If a maintenance information carefully cards, install protective devices to limit M9384B VXG exceeds the full before using the product. fault current and voltage to the card. temperature range, always allow it to...
  • Page 4 Chassis connections must only be used To return unwanted products, contact Authority mark to indicate regulatory as shield connections for measuring your local Keysight office, or for more compliance as a registered supplier. circuits, NOT as safety earth ground information see connections.
  • Page 5 Forty years is the expected useful life of the product. Universal recycling symbol. This symbol indicates compliance with the China standard GB 18455-2001 as required by the China RoHS regulations for paper/fiberboard packaging. M9384B Startup Guide...
  • Page 6 This page has been intentionally left blank...
  • Page 7: Table Of Contents

    Contents Introduction Related Documentation Documentation Access Items You Will Need M9384B Front and Rear Panel Connectors Front Panel Connectors Rear Panel Connectors Equipment Ratings Power Requirements Environmental Conditions (Operating) Weight and Dimensions Step 1: Unpack, Inspect, and Verify Shipment Safety Information...
  • Page 8 Running a Remote Desktop Session Windows Shortcuts and Miscellaneous Tasks Trigger Routing Step 4: Verify Operation  of the Signal Generator Conduct a Self Test Step 5: Generate and View an Output Signal Step 6: Installation is Complete M9384B Startup Guide...
  • Page 9: Introduction

    Introduction  The scope of this Startup Guide is to detail the processes of receiving the M9384B VXG. If you have any questions after reviewing this information, please contact your local Keysight Technologies Inc. representative or contact us through our website at www.keysight.com/find/M9384B. ...
  • Page 10: Documentation Access

    Introduction  Documentation Access  Documentation Access  M9384B Startup Guide...
  • Page 11: Items You Will Need

    To complete the startup process and begin using the instrument, you will need the following items:  A Keysight signal analyzer with the appropriate frequency range to measure the output of the M9384B VXG. An Open End Wrench (PN: 8710-1761) to hold and prevent the RF adapters from turning while connecting an external cable.
  • Page 12 This page has been intentionally left blank M9384B Startup Guide...
  • Page 13: M9384B Front And Rear Panel Connectors

    M9384B VXG Microwave Signal Generator Startup Guide M9384B Front and Rear Panel Connectors Front Panel Connectors Connector Type Description 19.2 GHz Out 1 SMA female Outputs a selectable CW 19.2 GHz frequency reference. 19.2 GHz Out 2 SMA female Outputs a selectable CW 19.2 GHz frequency reference.
  • Page 14 M9384B Front and Rear Panel Connectors Front Panel Connectors Connector Type Description AM In BNC female Accepts an external amplitude modulated signal. Pulse In BNC female Provides an input or output signal for trigger and events. Pulse Video Out SMB male Provides an input or output signal for trigger and events.
  • Page 15: Rear Panel Connectors

    M9384B Front and Rear Panel Connectors Rear Panel Connectors Rear Panel Connectors Connector Type Description 10 MHz In BNC female Accepts an external clock to be used as the system ref- erence frequency. 10 MHz Out BNC female Outputs a 10 MHz reference frequency or a calibration signal.
  • Page 16: Equipment Ratings

    M9384B Front and Rear Panel Connectors Equipment Ratings Equipment Ratings The M9384B VXG can operate with mains supply voltage fluctuations up to ± 10% of the nominal voltage. Power Requirements Power in Watts, VA or Current Frequency and/or range (Hz)
  • Page 17: Step 1: Unpack, Inspect, And Verify Shipment

    M9384B VXG Microwave Signal Generator Startup Guide Step 1: Unpack, Inspect, and Verify Shipment  Safety Information Unpack and Inspect the Instrument Return an Instrument for Service Verify M9384B VXG Shipment Contents ESD  Electrostatic discharge (ESD) can damage or destroy electronic components. Use a static-safe work station to perform all work on electronic assemblies.
  • Page 18: Safety Information

    Maintenance To remove dirt or dust from the external case of the M9384B VXG, clean the case using a dry or slightly-dampened cloth only. To prevent electrical shock, disconnect the AC/DC adapter from the mains before cleaning.
  • Page 19: General Safety Considerations

    This product must be used in a normal condition (in which all means for protection are intact) only. The M9384B VXG is heavy and requires two people to lift and carry it. Do not attempt to lift or carry it on your own. Before Applying Power...
  • Page 20: For The Ac/Dc Adapter

    Use only the designated AC/DC adapter supplied with the instrument. Use a Keysight supplied power cord that has the same or better electrical rating. Capable of rendering an electrical shock or burn. To prevent electrical shock, disconnect the intrument from the mains before cleaning.
  • Page 21 The AC/DC adapter is designed for use in Installation Category II and Pollution Degree 2 per IEC 61010-1. The main power cord can be used as the system disconnecting device. It disconnects the mains circuits from the mains supply. M9384B Startup Guide...
  • Page 22: Unpack And Inspect The Instrument

    Should it become necessary to return an instrument for repair or service, follow the steps below:  1. Review the warranty information shipped with your product. 2. Contact Keysight to obtain a Return Material Authorization (RMA) and return address. For assistance finding contact information, visit www.keysight.com/find/assist.
  • Page 23: Verify M9384B Vxg Shipment Contents

    Step 1: Unpack, Inspect, and Verify Shipment  Verify M9384B VXG Shipment Contents M9384B Rear Panel and Front Panel jumper cables (PN: W1312-20511 and W1312-20516) come with protective caps to protect them from impact damage during shipping. When returning an instrument for service, reinsert the protective caps (if available) or remove the cables and place them in a separate protective bag.
  • Page 24 This page has been intentionally left blank M9384B Startup Guide...
  • Page 25: Step 2: Download The Latest Documentation

    For the worldwide contact information for repair and service, visit www.keysight.com/find/assist. To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL: www.keysight.com/find/MyKeysight Information on preventing M9384B VXG damage can be found at:...
  • Page 26 This page has been intentionally left blank M9384B Startup Guide...
  • Page 27: Step 3: Prepare And Power Up The Signal Generator

    M9384B VXG Microwave Signal Generator Startup Guide Step 3: Prepare and Power up the Signal Generator Before Powering up the Instrument Prepare and Power up the Instrument Installed Software User Accounts Windows Configuration Configuring LAN Windows Security System Maintenance USB Connections...
  • Page 28: Chassis Air Flow

    Step 3: Prepare and Power up the Signal Generator Prepare and Power up the Instrument  Chassis Air Flow  The M9384B VXG has multiple air intakes. They are located at the lower sides, lower front and bottom of the instrument.  Prepare and Power up the Instrument ...
  • Page 29: Installed Software

    SYSTem:PDOWn Customer Installation of Software Installation of other Third Party Software The M9384B VXG platform is an Open Windows environment, so you can install software on the instrument. However, installation of non-approved software may affect instrument performance. M9384B Startup Guide...
  • Page 30: User Accounts

    User names are not case sensitive but passwords are case sensitive. It is Keysight’s expectation that each user’s My Documents folder is mapped to the D: drive. This is to avoid overwriting the user’s data in the event the Instrument...
  • Page 31: Windows Configuration

    Microsoft recommends that you always get the latest critical Windows updates to ensure that the instrument's Windows operating system is protected. If the instrument has Internet access, the instrument default is set to automatically check for critical Windows Updates and notify you. Setup new user accounts. M9384B Startup Guide...
  • Page 32 Hardware tab. In this dialog, there is a Advanced tab. You should not modify any settings under the Advanced tab except as described above under Settings that can be Changed. Do not remove installed Fonts M9384B Startup Guide...
  • Page 33 In addition, Do not: Add, delete, or modify disk drive partitions. Delete or modify Keysight registry entries. Change the contents of any directories containing the name "Keysight". Stop the IIS server Tamper with any virtual directories (or their contents) that come configured with the instrument.
  • Page 34: Configuring Lan

    To map a network drive, click Start > System Tools > Computer. Go to Computer tab, and select Map Network Drive from the drop down menu: In the Map Network Drive dialog, browse to the correct folder, and click Finish. M9384B Startup Guide...
  • Page 35: Windows Security

    LAN. Do not modify the default network settings as this may cause problems to the operating system of the M9384B VXG. The M9384B VXG is shipped with the Windows 10 firewall enabled and Windows Defender. You can verify the...
  • Page 36: Automatic Updates

    To adjust Windows Defender settings, log in as an administrator (default password:"Keysight4u!"). Minimize the M9384B VXG application, click Start and type: defender. Click Windows Defender from the Best match column. Automatic Updates Microsoft recommends that you always get the latest critical Windows updates to ensure that the instrument's Windows operating system is protected.
  • Page 37: System Restore

    Customer Installation of Software for more information. While performing backups, Keysight recommends that you backup the data to an external storage device connected to the network or one of the instrument's USB connectors. Also, you should perform backups at times when the instrument is not being used for normal operations, as it may impact the instrument's overall performance.
  • Page 38: Disk Drive Partitioning And Use

    The E: partition is reserved for Keysight’s use. The primary use of the E: drive is for housing the Calibration and Alignment data. Do not change or overwrite the files on this drive.
  • Page 39 Step Notes 1. Make sure the instrument is turned off. 2. Turn on the instrument. After the Keysight Technologies screen is displayed, Press the Down Arrow key to move the highlight to Instru- This screen is displayed for five seconds.
  • Page 40 4. A warning message appears. Press Enter to start the recov- ery, which may take up to 25 minutes to complete. 5. Press Enter to exit and reboot the instrument once this portion of the recovery has completed. M9384B Startup Guide...
  • Page 41: Updating The Software (Required After A Recovery)

    DO NOT turn off the instrument power at this time for ANY reason. If this process is interrupted, the instrument most likely needs to be sent back to an Keysight Service Center for servicing before it is usable again.
  • Page 42: Using Windows Tools

    Exits/closes a Windows dialog box (does not exit an Application window) Enter Does the current default action. If a menu item or a button is currently highlighted, then the Enter key activates that menu item or button. M9384B Startup Guide...
  • Page 43: Remote Desktop: Using The Signal Generator Remotely

    The Remote Desktop functionality is a Microsoft Windows 10 capability. The following discussion provides some guidelines for using this capability with the instrument. Refer to the Windows 10 help documentation for more information. As Windows evolves, these instructions may no longer be exact. M9384B Startup Guide...
  • Page 44: Overview Of Remote Desktop Operation

    In the Control Panel Home window, select Remote settings 4. Select the Remote option. On the Remote tab in the Remote Desktop section, click the appropriate checkbox. 5. To add users. Click Select Users > Add. 6. Follow the on screen instructions. M9384B Startup Guide...
  • Page 45: How To Locate The Computer Name Of The Instrument

    Connectivity. However, you need to have a Windows installation CD-ROM available to run the Client software. The following instructions relate to software provided by Microsoft Corporation. Keysight offers no warranty regarding the operation of such software. The procedure described here may be changed by Microsoft at some future time.
  • Page 46: Running A Remote Desktop Session

    Enter the computer name of the instrument. Click Connect. A login dialog box appears. Enter the login account name and The default account name is "Instrument" and the default password. password is "measure4u", but these parameters may be changed by instrument users. M9384B Startup Guide...
  • Page 47 2. Under the General tab, ensure that the computer You may choose to enter the name, User name and Domain name are set correctly. password and save it for future sessions, by selecting the Save my password box. M9384B Startup Guide...
  • Page 48 More… button. 4. Click the Experience tab. To optimize the performance of the Remote Desktop session, choose the appropriate connection format from the drop-down list. M9384B Startup Guide...
  • Page 49: Windows Shortcuts And Miscellaneous Tasks

    Windows 10 system, they are not commonly used when a mouse and keyboard are attached. Windows Shortcuts (Key Combinations) You can use the following combinations of front panel keys to perform basic windows tasks when using the instrument without an attached mouse and keyboard. M9384B Startup Guide...
  • Page 50 Restoring Taskbar Auto-Hide Mode Step Notes Click Start > Control Panel. If not using a mouse, press Ctrl+Esc. Click Taskbar and Start Menu. If you are not using a mouse, use the shortcut key combinations specified in the Windows M9384B Startup Guide...
  • Page 51: Trigger Routing

    This applies the change and closes the dialog box. Trigger Routing  The M9384B VXG supports the following triggering modes for starting modulation. Immediate (Default) Modulation begins as soon as the Vector Modulator is ready. External Triggering Can be used for synchronization with an external trigger source for starting waveform playback.
  • Page 52 This page has been intentionally left blank M9384B Startup Guide...
  • Page 53: Step 4: Verify Operation  Of The Signal Generator

    M9384B VXG Microwave Signal Generator Startup Guide Step 4: Verify Operation  of the Signal Generator In this step, the operation of the M9384B VXG is verified. Before running the verification procedure, ensure that the instrument is powered on.  Conduct a Self Test ...
  • Page 54 This page has been intentionally left blank M9384B Startup Guide...
  • Page 55: Step 5: Generate And View An Output Signal

    1. Power on the Keysight Signal Analyzer. 2. Connect a high-quality male (2.4 mm) to SMA (male) cable between the Front Panel RF Out connector and the RF In connector on the Keysight Signal Ana- lyzer. 3. Torque the connectors to 8 In-lb (0.904 Nm).
  • Page 56 For two channel instruments only: In the top right corner of the display, set RF Out (All) to On by selecting the switch. 5. On the Keysight Signal Analyzer, select AUTO TUNE in the Frequency menu. You should see the following display on your Keysight Signal Analyzer.
  • Page 57: Step 6: Installation Is Complete

    M9384B VXG Microwave Signal Generator Startup Guide Step 6: Installation is Complete  Proceed to program your product by means of the SCPI programming interface. ...