Installation In A Rack - Fujitsu DX100 S3 Setup Manual

Hybrid storage systems
Hide thumbs Also See for DX100 S3:
Table of Contents

Advertisement

Installation in a Rack

STEP
The rack rail needs to be attached to the rack and the controller enclosure or the drive enclosure needs to be
installed.
Configuration Guide (Basic)
IMPORTANT
Controller Enclosures and Drive Enclosures (2.5" type/3.5" type)
1.
Attach the rack rails to the rack.
The size of the controller enclosure and each drive enclosure is 2U.
Plate
M5 screws
(Front rack pillars)
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Setup Guide
Drive enclosures must be installed above
the controller enclosure. When installing
multiple drive enclosures, install them in the
order of the "DE_No. label" numbers that are
attached to the drive enclosures.
The DE_No. labels are attached on the
locations that are shown in the figure on the
right.
The center of gravity must be taken into
consideration to prevent a rack from toppling
over. The controller enclosure and drive
enclosures should generally be installed from
bottom to top to lower the center of gravity
and to ensure the safe use of racks.
Rack rail (for left side)
Washers
Plate
M5 screws
Rack rail (for right side)
Copyright 2017 FUJITSU LIMITED
Right front side
of the drive enclosure (2.5" type/3.5" type)
Right front side
of the high-density drive enclosure
(Rear rack pillars)
M5 screws
M5 screws
Washers
2
Upper rear side
of the drive enclosure (2.5" type/3.5" type)
DE_No. labels
Upper rear side
of the high-density drive enclosure
DE_No. labels
P3AM-7852-06ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx200 s3

Table of Contents