Maintenance

Transaxle Fluid

Service Interval/Specification
Check fluid level after every 100 hours or yearly
whichever comes first. Always keep the fluid level at
the full level when the transaxle is cold. The transaxle
is a sealed system and no changing of the fluid is
required.
Fluid Type: SAE 10W–30 Detergent oil (API service
SF or SG)
Checking Fluid Level
1.
Park the machine on a level surface, disengage
the power take off (PTO), set the parking brake,
and turn the ignition key to "OFF" to stop the
engine. Remove the key. Remove the key.
2.
Open the hood.
3.
Clean around the fluid reservoir (Fig. 31) so
level is clearly visible and so dirt cannot fall into
the reservoir if fluid is added.
4.
When transaxle is cold add oil to "Full Cold"
line on reservoir (Fig. 31).
IMPORTANT: Do not fill above the full cold
line as fluid may overflow.
1
Figure 31
1. Fluid reservoir
28
2
1243
2. Full cold level

Fuse

Service Interval/Specification
The electrical system is protected by fuses. It requires
no maintenance, however, if a fuse blows check
component/circuit for malfunction or short. To
replace fuses pull up on the fuse (Fig. 32) to remove
or replace it.
Fuse:
Dash/Hour meter F1–5 amp, blade-type
Head lights F2–10 amp, blade-type
Alternator F3–25 amp, blade-type
Main/Starter F4–30 amp, blade-type
Figure 32
1. Dash/Hour meter-5 Amp
2. Head lights-10 amp
4
3
2
1
2344
3. Alternator-25 amp
4. Main-30 amp

Hide quick links: