Mitsubishi Electric PUHZ-P200 Installation Manual
Mitsubishi Electric PUHZ-P200 Installation Manual

Mitsubishi Electric PUHZ-P200 Installation Manual

Mr. slim puhz-p series
Hide thumbs Also See for PUHZ-P200:

Advertisement

Air-Conditioners
PUHZ-P·YHA Series
INSTALLATION MANUAL
For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
intérieur pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d'installazione dell'unità
interna prima di installare il condizionatore d'aria.
EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο καθώς και το εγχειρίδιο εγκατάστασης
της εσωτερικής μονάδας, προτού εγκαταστήσετε τη μονάδα του κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
interior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras
så att den används på ett säkert och korrekt sätt.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство
и руководство по установке внутреннего прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
Eλληνικά
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PUHZ-P200

  • Page 1 Air-Conditioners PUHZ-P·YHA Series INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
  • Page 2: Table Of Contents

    Consult a dealer regarding this could lead to a serious impediment to securing product safety. • Use only accessories authorized by Mitsubishi Electric and ask a dealer the appropriate measures to prevent the allowable concentration from be- ing exceeded.
  • Page 3: Installation Location

    1. Safety precautions 1.3. Before electric work Caution: • Be sure to ground the unit. Do not connect the ground wire to gas or water • Be sure to install circuit breakers. If not installed, electric shock may re- sult. pipes, lighting rods, or telephone grounding lines.
  • Page 4: Installing The Outdoor Unit

    2. Installation location 2.4.2. When installing a single outdoor unit (Refer to the last page) Minimum dimensions are as follows, except for Max., meaning Maximum dimen- sions, indicated. Refer to the figures for each case. Obstacles at rear only (Fig. 2-6) Obstacles at rear and above only (Fig.
  • Page 5: Installing The Refrigerant Piping

    4. Installing the refrigerant piping 4.1. Precautions for devices that use R410A refriger- • Refer to 1.5. for precautions not included below on using air conditioners with R410A refrigerant. • Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration oil applied to the flared sections.
  • Page 6 4. Installing the refrigerant piping 4.3. Refrigerant piping (Fig. 4-4) Remove the service panel (3 screws) and the front piping cover (2 screws) and rear piping cover (2 screws). Perform refrigerant piping connections for the indoor/outdoor unit when the out- door unit’s stop valve is completely closed.
  • Page 7: Drainage Piping Work

    4. Installing the refrigerant piping 4.6. Addition of refrigerant • Additional charging is not necessary if the pipe length does not exceed 30 m. • Be careful when installing multiple units. Connecting to an incorrect indoor unit can lead to abnormally high pressure and have a serious effect on operation •...
  • Page 8 6. Electrical work * In case of PEA-200, 250 PUHZ-200, 250 PEA-200, 250 * In case of PEA-400, 500 Power supply Earth leakage breaker (No.1 Outdoor) Circuit breaker or local switch PUHZ-200, 250 PEA-400, 500 LCD remote controller Outdoor unit Indoor unit Power cable wiring Indoor/Outdoor connection wiring...
  • Page 9: Test Run

    6. Electrical work Power supply Isolator 3 pole isolator A-Control A-Control Indoor Unit Outdoor Unit Warning: In case of A-control wiring, there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line and communication signal line.
  • Page 10: Special Functions

    8. Special Functions 8.1. Low noise mode (on-site modification) (Fig. 8-1) By performing the following modification, operation noise of the outdoor unit can be reduced by about 3-4 dB. Brown The low noise mode will be activated when a commercially available timer or the Orange Fig.

This manual is also suitable for:

Puhz-p250

Table of Contents