Optical Parts Disassemblies
Locations and Directions
When the optical parts in the optical unit mounting or assembling,
the parts must be mounted in the specified location and direction as
shown in figure below.
14
14
13
1
3
2
The printed marker
comes this side.
12
-17-
Key No.
Description
1
Condenser lens (R)
2
Condenser lens
3
Condenser lens
4
Mirror (B)
5
Optical filter (UV cut)
6
Dichroic mirror (B
7
Dichroic mirror (G)
8
Mirror (W)
9
Condenser lens (IN)
10
PBS (prism beam splitter)
11
Integrator lens (OUT)
12
Integrator lens (IN)
13
Relay lens (IN)
14
Mirror (R)
The cutting corner
comes to this side up.
The printed marker
comes this side.
9
10
11
Fig.7
4
5
6
7
8

Advertisement