Error Log - Sanyo PDG-DXL2000E Service Manual

Original version chassis no. kv2-dxl2000e00
Table of Contents

Advertisement

Troubleshooting

Error log

This projector provides the error history log function. To
check the logs, you need to enter the service mode and se-
lect Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of the
error code is listed on the table below.
* H ow to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Error
Error Code
Normal
0
1000
Power Failure
1001
2000
2001
2100
2101
Temperature Error
2102
2200
2201
2202
3000
Lamp Error
3001
3002
How to reset the error log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* H ow to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".
Error Infomation
-
MAIN,
P_FAIL
Errors on the power supply lines or Fan control
WHEEL, ERROR
Error on the color wheel
Sensor A detects abnormal temperature. (IC8801-ROOM)
Sensor A fails measurement. (IC8801)
Sensor B detects abnormal temperature. (IC8821-LAMP)
Sensor B fails measurement. (IC8821)
Sensors B-A temperature error.
Sensor C detects abnormal temperature. (IC8811-DMD)
Sensor C fails measurement. (IC8811)
Sensors C-A temperature error.
Lamp1 fails on
Lamp1 goes out
Communication Error on Lamp1
-42-
Group
Item
Data
No.
No.
(Error Code)
220
0
1
2
3
:
:
:
:
49