Power Supply - Philips CCS 800 Service Manual

Hide thumbs Also See for CCS 800:
Table of Contents

Advertisement

7.3

Power supply

Type of power supply
Mains input voltages
Input frequency range
Max. input current
Nominal output voltage
Rated output load
Dimensions
Fuse
AC
input
Additional technical specification for test environment:
Warning
:
heatsink is electrical connected to live of mains input depending on polarity!
Load range
Output
+24V
For a practical load test, connect e.g. a resistor of 15 Ohm (min. 40W) between the terminals +24V and
GND.
LBB 3310/00, 3330/00 and 3331/00
4822 861 11006
F1
L
K1
N
Min. load
Rated load
0A
1.7A
: Nedap 9553673
: 90 .. 264Vac
: 47 .. 63Hz
: 0.9A at 110Vac or 0.3A at 240Vac
: 24Vdc
: 1.7A
: 125mm x 75mm
Peak load
2.5A
page: 7
SERVICE MANUAL
K2
1
DC
output
6
Voltage accuracy
24 ±0.6V
Date of issue:
July 1998