Supply Current Measurement; Audio-Contr To Loudspeaker Circuit - Philips CCS 800 Service Manual

Hide thumbs Also See for CCS 800:
Table of Contents

Advertisement

10.2.4 Supply current measurement

Measure the supply current from V+ by means of a current meter in the power supply line itself: this should be between
30mA and 40mA.
~
~
90 ... 264V AC / 24V DC

10.2.5 AUDIO-CONTR to Loudspeaker circuit

Noise level
Measure first the noise, A-weighted & rms, from the loudspeaker-signal between (symmetrical) M57 and M59 (see figure
2):
Noise level (A-weighted): < -70dBV.
X10
X110
LBB 3310/00, 3330/00 and 3331/00
4822 861 11006
K2
Power Supply
1,2,3
4,5,6
90 ... 264V AC
~
~
Power Supply
AC
24V DC
PCB CPSU
Loudspeaker
(GND)
M110 M111
M121
M122 M124
6
9
4
8
Line-IN
Rec-IN
Rec-IN
L
A1
A
+
-
X10
3
V+
1
V-
Figure 1
X205 M59
25Ω
M57
(GND)
(GND)
M150 M151
X150
2
7
2
5
Telephone
R
IN
Figure 2