100 Hour Burn-In Mode; Request Application Mode; Mass Programming - Philips OccuSwitch DALI LRM2070 User Manual

Hide thumbs Also See for OccuSwitch DALI LRM2070:
Table of Contents

Advertisement

Calibration with remote control
1 Place a light meter on a representative
II
I/ II
place .
BMS
PL
W/C
1
2
3
10% A
20% B
30% C
4
5
6
40% D
50% E
60% F
7
8
9
2 Measure the light level and adjust it by
70% G
on
0
o
min
pressing the up or down Arrow keys .
group
save
3 If the light level is adjusted to the correct
con g
mode
O)))
value, press the Save button .
link?
mode?
test
100 h
add
zone
The luminaires blinks to indicate that the
%
A-G
on/o
0
power up background IR group
reset
setting has been stored .
delay
pir
daylight RF channel
scene
D Note
At all actions, stay close to the OccuSwitch DALI and
point the remote control towards the sensor .
4 .2 .5

100 hour burn-in mode

Most lamp manufacturers advise not to dim (to a low level)
the fluorescent lamps for a period of 100 hours prior to
normal use, in order to maintain light quality at (very) low
dimming level .
The OccuSwitch DALI 100h burn-in mode adapts all
dimming functions during this period, to make sure that
the lights are not dimmed . Only during walk test (to test
the installation) and commissioning, dimming is allowed to
make the necessary adjustments .
1 Point the remote towards the
II
I/ II
OccuSwitch DALI and press 100h to
BMS
PL
W/C
1
2
3
10% A
20% B
30% C
enable or to disable the parameter .
4
5
6
40% D
50% E
60% F
7
8
9
70% G
on
0
o
min
The luminaires will flash once to confirm
group
the selection .
save
con g
mode
O)))
When the 100h burn-in mode is active,
link?
mode?
test
100 h
the LEDs on the OccuSwitch DALI are
add
zone
continuously green when the lights are
%
A-G
on/o
0
power up background IR group
reset
switched on . (The LED may blink when
delay
pir
daylight RF channel
motion is detected) .
scene
4 .2 .6

Request application mode

The OccuSwitch DALI controller has 10 pre-defined
application Modes . The default application mode is Mode
1 (Cell office) . The IRT9090 can be used to request the
actual application mode .
1 Point the remote towards the
II
I/II
OccuSwitch DALI and press Mode?
BMS
PL
W/C
1
2
3
10% A
20% B
30% C
4
5
6
40% D
50% E
60% F
7
8
9
The luminaires dim, and then start to flash .
70% G
0
on
o
min
The number of light flashes is equal to the
group
actual application mode, as displayed in
save
figure below .
con g
mode
O)))
link?
mode?
test
100 h
add
zone
100%
%
A-G
0
on/o
power up background IR group
reset
delay
pir
daylight RF channel
1%
scene
4 .2 . 7

Mass programming

To ease the commissioning process of a whole installation,
the IRT9090 can be pre-programmed with the application
mode, the background level, the power-up state and
infrared group address . These four settings will remain
stored in the IRT9090 remote, and are sent each time the
green Send button of the remote is pressed . For resetting
these values, see section 4 .3 .
OccuSwitch DALI
User Guide
Page 33
5 ashes = Mode 5
Press "mode?" button

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents