Setup menus
(continued)
USER menu
<TIME CODE>
No./Item
500
For selecting whether to output the VITC
signal at the positions selected by setup
VITC BLANK
menu items No. 501 (VITC POS-1) and No.
502 (VITC POS-2).
0000 BLANK : VITC signals are not output.
0001
THRU : VITC signals are output.
501
This sets the position where the VITC signal
is to be inserted.
VITC POS-1
[625i system] [525i system]
0000
:
0004
:
0015
<Note>
The same line as the one used for the setup
menu items No. 502 (VITC POS-2) and No. 662
(UMID POS) setting cannot be set.
502
This sets the position where the VITC signal
is to be inserted.
VITC POS-2
[625i system] [525i system]
0000
:
0006
:
0015
<Note>
The same line as the one used for the setup
menu items No. 501 (VITC POS-1) and No. 662
(UMID POS) setting cannot be set.
503
This selects the signal to be regenerated
when the time code generator (TCG) in the
TCG REGEN
REGEN mode.
0000 TC&UB :
Both the time code and user bit are
regenerated.
0001
Only the time code is regenerated.
0002
Only the user bit is regenerated.
504
This selects whether the time code is to be
regenerated during automatic editing using
REGEN MODE
the unit's control panel.
0000
AS&IN :
Time code is regenerated with assemble or
insert editing.
0001 ASSEM :
Time code is regenerated with assemble
editing.
0002
INSRT :
Time code is regenerated with insert editing.
0003
Setting complies with TC (REGEN/PRESET)
switch setting.
The underlined items indicates the initial setting.
Description
7L 0000
10L
:
:
:
11L 0006
16L
:
:
:
22L 0010
20L
7L 0000
10L
:
:
:
13L 0008
18L
:
:
:
22L 0010
20L
TC :
UB :
SW :
No./Item
505
This selects the time code to be used when
an external time code is to be used.
EXT TC SEL
0000
LTC :
The LTC of the TIME CODE IN connector is
used.
0001
VITC :
The VITC of the input video signal is used.
506
This sets the usage status of the user bit of
the time code generated by the TCG.
BINARY GP
0000
000 :
NOT SPECIFIED (character set not specified)
0001
001 :
ISO CHARACTER (8 bits character set based
on ISO646, ISO2022)
0002
010 : UNASSIGNED 1 (undefined)
0003
011 : UNASSIGNED 2 (undefined)
0004
100 : UNASSIGNED 3 (undefined)
0005
101 : PAGE/LINE
0006
110 : UNASSIGNED 4 (undefined)
0007
111 : UNASSIGNED 5 (undefined)
507
This selects whether to control the phase
correction of the LTC which is output from
PHASE CORR
the TIME CODE OUT connector.
0000
OFF :
Phase correction control is not performed.
0001
Phase correction control is performed.
508
This selects whether the CF flag of the TCG
is to ON.
TCG CF FLAG
0000
OFF : CF flag is OFF.
0001
509
This selects the DF or NDF mode for CTL and
TCG.
DF MODE
0000
0001
NDF : The non-drop frame mode is
<Notes>
OThe drop frame mode takes effect when the
REMOTE button is set to the local mode
(REMOTE lamp OFF) or when ENA has been
selected as the setup menu item No.001
(LOCAL ENA).
OThis setup menu is not displayed in the 625i
system.
510
This is used to switch the phase of the time
code, which is output from the TIME CODE
TC OUT REF
OUT connector, for the external LTC input
when the TCG switch is at the EXT position.
0000
V OUT :
Time code is synchronized with output video
signal.
0001
TC_IN :
Time code is synchronized with external time
code input.
Description
ON :
ON : CF flag is ON.
DF : The drop frame mode is used.
used.
49 (E)