• Program for Zone 1, Zone 2 (if present), Zone 3 (if present),
DHW (Domestic hot water) and recirculation.
Time ranges (calendars from 1 to 4) are assigned to Zone 1, Zone
2 (if present), Zone 3 (if present), DHW (Domestic hot water)
and Central heating / C.H. in these menus.
You can assign the calendar to a single day or to a group of days
(single day, Monday - Friday, Saturday - Sunday, Monday - Sat-
urday, Monday - Sunday).
Therefore each day may be personalised with 4 different operat-
ing programs.
For convenient selection, the bottom part displays the graphics
of the relevant calendar being selected (Fig. 30).
IMPOSTA DATA E ORA
Zone 1 program
Day/s:
Calendar:
1
0 2
4
6
8 10 12 14 16 18 20 22 24
On the menu
Zones/Information
it is possible to identify the status of the various controls
managing the central heating / C.H..
• Holiday program.
If required, it is possible to pause system operation for an estab-
lished period.
Time and program/Holiday program
Set the period in which you wish to pause system operation.
During this time, the previously set calendars will not be taken
into consideration, modifying the menu.
Set the period in which you wish to pause system operation.
During this time, the previously set calendars will not be taken
into consideration.
The antifreeze function is still ensured during the holiday peri-
od.
Monday - Sunday
Heat pump disabling
It is possible to disable the heat pump operation for a certain time
slot, by setting
User/Disable Heat pump = Yes
and the start and end times of disabling.
Integration Disabling
The use of the integration electrical resistances can be permanent-
ly disabled by setting
User/Disable Integration = Yes.
Automatic Vent Function
In the case of new systems and, in particular, for floor systems, it is
very important that de-aeration is performed correctly.
The function consists of the cyclic activation of the pumps and the
3-way valve.
The function is activated by setting
User/Enable Deaeration func. = Yes.
De-aeration lasts 9 hours and it can be interrupted by setting
User/Enable Deaeration func. = No.
30
39
Need help?