  • Page 1 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640...
  • Page 2 Distributed by: Manufacturer: KaVo Dental Technologies, LLC Kaltenbach & Voigt GmbH 11727 Fruehauf Drive Bismarckring 39 Charlotte, NC 28273 USA 88400 Biberach Phone: 847 550 6800 Germany Fax: 847 550 6825 www.kavo.com...
  • Page 3: Table Of Contents

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 Table of contents Table of contents 1 User instructions ........................ 5 2 Safety..........................8 2.1 Infection hazard ......................8 2.2 Improper use ........................ 8 2.3 Technical condition ......................8 2.4 Accessories and combination with other equipment............
  • Page 4 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 Table of contents 9 Terms and conditions of warranty ..................27 4 / 30...
  • Page 5: User Instructions

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 1 User instructions 1 User instructions Dear User, Congratulations on purchasing this KaVo quality product. By following the in- structions below you will be able to work smoothly, economically and safely.
  • Page 6 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 1 User instructions Information on the packaging Catalog number Serial number Legal Manufacturer CE mark according to Medical Devices Directive EC 93/42 Please note the electronic instructions for use...
  • Page 7 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 1 User instructions NOTICE In cases which – if not prevented – can lead to property damage. 7 / 30...
  • Page 8: Safety

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read care- fully prior to use and be accessible at all times.
  • Page 9: Accessories And Combination With Other Equipment

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 2 Safety | 2.4 Accessories and combination with other equipment ▶ Check to make sure that the device is working properly and is in satisfac- tory condition before each use.
  • Page 10 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 2 Safety | 2.6 Service and repair ▪ Service technicians of KaVo authorized dealers after the appropriate product training Comply with the following items during all servicing work: ▶...
  • Page 11: Description Of The Product

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 3 Description of the product | 2.6 Service and repair 3 Description of the product MASTERmatic LUX M25 L (Mat. no. 1.009.3630) MASTERmatic LUX M05 L (Mat. no. 1.009.3640) The MASTERmatic LUX electrical-driven handpieces are dental handpieces in ac- cordance with 21 CFR §...
  • Page 12: Intended Use

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 3 Description of the product | 3.1 Intended use 3.1 Intended use Indications for use: The MASTERmatic LUX handpieces are intended for the removal of carious ma-...
  • Page 13 Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 3 Description of the product | 3.3 Transportation and storage conditions Relative humidity: 5% RH to 95% RH absence of condensation Air pressure: 700 hPa to 1060 hPa (10 psi to 15 psi)
  • Page 14: Startup And Shut-Down

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 4 Startup and shut-down | 4.1 Checking the water quantity 4 Startup and shut-down WARNING Hazard from non-sterile products. Infection hazard for dentist and patient.
  • Page 15: Operation

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 5 Operation | 5.1 Attach the medical device 5 Operation CAUTION Heat transmission during the preparation of abutments. Thermal damage to the jawbone. ▶ During the preparation of abutments, make sure that the preparation times are short and that there is sufficient cooling.
  • Page 16: Removing The Medical Device

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 5 Operation | 5.2 Removing the medical device 5.2 Removing the medical device ▶ Unlock the medical device from the motor coupling by twisting it slightly and then pulling it along its axis.
  • Page 17: Removing The Milling Tool Or Diamond Grinder

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 5 Operation | 5.4 Removing the milling tool or diamond grinder ▶ Forcefully press the push-button with your thumb and simultaneously insert the bur to the bur stop.
  • Page 18: Checking For Malfunctions And Troubleshooting

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 6 Checking for malfunctions and troubleshooting | 6.1 Check for malfunctions 6 Checking for malfunctions and troubleshooting 6.1 Check for malfunctions CAUTION Product heats up.
  • Page 19: Cleaning The Spray Nozzle

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting Note The O-rings on the coupling may only be lubricated with a cotton ball wetted with KaVo Spray.
  • Page 20: Reprocessing Steps In Accordance With Iso 17664

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.1 Preparations at the site of use 7 Reprocessing steps in accordance with ISO 17664 7.1 Preparations at the site of use WARNING Hazard from contaminated products.
  • Page 21: Manual External Disinfection

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.2 Manual processing 7.2.3 Manual external disinfection WARNING Incomplete disinfection. Infection hazard. ▶ Only use disinfection procedures that are verified to be bactericidal, fungici- dal and virucidal.
  • Page 22: Automated Processing

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.3 Automated processing 7.3 Automated processing WARNING Incomplete disinfection. Infection hazard. ▶ Only use disinfection procedures that are verified to be bactericidal, fungici- dal and virucidal.
  • Page 23: Care Products And Systems - Servicing

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.4 Care products and systems - Servicing 7.4 Care products and systems - Servicing WARNING Sharp tool in the medical device.
  • Page 24: Packaging

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.5 Packaging Servicing the chuck KaVo recommends servicing the chuck system once a week using the chuck servicing program integrated in the device.
  • Page 25: Storage

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 7 Reprocessing steps in accordance with ISO 17664 | 7.7 Storage NOTICE Contact corrosion due to moisture. Damage to the product. ▶ Remove the product from the steam sterilization immediately after the sterilization cycle.
  • Page 26: Tools And Consumables

    Instructions for use MASTERmatic LUX M25 L - 1.009.3630 MASTERmatic LUX M05 L - 1.009.3640 8 Tools and consumables 8 Tools and consumables Available from dental suppliers. Material summary Mat. No. INTRA instrument stand 3.005.5204 Cellulose pad 100 units 0.411.9862 Cleanpac 10 units 0.411.9691...