INSTALLATION
3.11

INSTALLING SENSOR PROBES

To install the probe:
1. Unscrew the plate from the ceiling panel to get
access to the conduit for the probe wire. A coloured
piece of wire acting as a draw string is located
behind the plate in the conduit
Sensory Probes are located under this labelled
panel.
Ensure case earthed when proceeding
with electical components. Electric
shock or fire may occur if not correctly
processed.
NOTE:
should be as per the control system's
recommendations.
system's sensors require air to be in
same direction as sensor, others at 90°
The discharge air control sensor
should be located in the air stream
only and should not make contact with
any metal parts. .
PAGE 26
FIGURE 3AD
The
sensor
orientation
Some
control
CAUTION:
Territory legislation relating to safe
working heights
2. Secure the end of the sensor wire to the draw string
wire.
3. On the roof of the case, pull draw wire and sensor
wire all the way through the conduit.
4. Seal end of the conduit with putty or silicon
5. Repeat for each case
CAUTION:
cabinet is limited to 100kg personnel
and only when the cabinet is empty
of product/merchandise. Do not walk
atop cabinets, sedentary work/access
only is permitted. Always have suitable
PPE and working from heights SWMS
in place. Work as far from edges as
feasible. If unsafe, do not access the
top of the cabinet
3.12
MOUNTING FIXTURES
NOTE:
Replace racks and shelves etc,
as necessary to store requirements.
Incorrect pan and display tag
configurations may compromise case
performance.
SMED SEMI VERTICAL - HUSSMANN