1. SafEtY
Warning! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
maintain the calibration rig in good condition.
9
replace or repair damaged parts. Use genuine parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
9
locate the calibration rig in a suitable working area, keep area clean and tidy and free from unrelated materials.
9
Keep the calibration rig clean to ensure accurate performance.
9
Do not use outside in damp or wet weather conditions.
8
Do not allow untrained persons to operate the calibration rig.
8
Do not leave the calibration rig unattended.
8
Warning! the warnings, cautions and instructions contained within this document cannot cover all possible conditions and situations
that may occur. it must be understood that common sense and caution are factors which cannot be built into this product, but must be
applied by the operator.
laSEr SafEtY
the ms070 utilises a class 2m laser that emits low levels of visible radiation light (i.e. wavelengths between 630 and 640 nanometres)
which are safe for the skin but not inherently safe for the eyes. the class 2m emission limit is set at the maximum level for which eye
protection is normally afforded by natural aversion responses to bright light. Accidental eye exposure is therefore normally safe,
although the natural aversion response can be overridden by deliberately staring into the beam, and can also be influenced by the use
of alcohol or drugs.
Warning! Do not look or stare into the laser beam as permanent eye damage could result.
Do not direct the laser beam at any person's (or animal's) eyes as eye damage could result. if the beam is obstructed by a person
8
during use, release the contact switch immediately.
Do not use the equipment while under the influence of alcohol, drugs or whilst on medication.
8
Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye
9
exposure.
2.
introDuction
in
used to check and adjust the alignment of the lasers on model no. ms070 motorcycle Wheel Alignment tool. this unit will allow workshops to
check and adjust in-house.
3.
SEt up
in
3.1.
rig set up
3.1.1.
the twin laser units as seen in fig.1 need to be clamped
either side of the calibration rig as shown in fig.2.
3.1.2.
Position the left hand laser unit with the rod attached on the left hand
side of the rig and insert the rod through the hole in the rig. slide the
right hand laser unit onto the rod and up to the other side of the rig,
followed by the spring and clamp unit.
3.1.3.
ensure that the shouldered fixing on the side of the left hand laser from
which the rod emerges, passes into the hole in the side of the rig so that
both laser units lay completely flush either side of the calibration rig.
© Jack sealey limited
instructions for
calibration rig for MS070
model no:
t
Original Language Version
MS070cr
fig.1
ms070cr | issue 3(l) 20/02/17

Advertisement

loading

Summary of Contents for Sealey MS070CR

  • Page 1 MS070cr model no: thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. sole uK distributor, sealey Group. 01284 757500 www.sealey.co.uk Kempson Way, suffolk Business Park, Bury st. edmunds, suffolk. 01284 703534 sales@sealey.co.uk iP32 7Ar © Jack sealey limited Original Language Version ms070cr | issue 3(l) 20/02/17...