4.6.2 Application with master-slave process data transfer

Master
Slave
Slave-to-slave data
transfer
Application Module FM 458-1 DP - User Manual
A5E01078222-02
Edition 03.2009
The automation system with SIMOLINK interface is generally configured
as the SL master. Whereby, all of the other coupling nodes are set as
slaves/transceiver (refer to MASTERDRIVES option module SLB
SIMOLINK).
The number of channels used for each slave/transceiver is defined by the
SIMOLINK function blocks (connections CTV, CSV).
SIMATIC S7-400 oder SIMADYN D
SIMOLINK
SIEMENS
SIMOVERT SC
6SE7016- 1EA 30
WR 2,2 kW
Nr. 4 67321
Transceiver
Fig. 4-15
Application example for master-slave process data transfer
 The SL master can read and write into all of the channels of all of the
slaves/transceiver.
Configuring data:
Function block @SL:
For each slave:
 Each slave can read all of the channels and write into a max. of 8
(own!) channels.
Configuring data:
Function block @SL:
For each read channel:
For each write channel:
 In order to transfer data from slaves/transceivers to
slaves/transceivers which are physically located in front in the ring, in
the same bus cycle, the slave-to-slave communications setting must
be used.
Configuring data:
Function blocks SLAV and SLDIS: Connection QV = 1
SIMADYN D
Master
SIEMENS
SIMOVERT SC
6SE7016- 1EA 30
WR 2,2kW
Nr. 467321
Transceiver
Transceiver
MOD connection = 1...5 or 10
e.g. one SLSVAV
MOD connection= 0
e.g. one SLAV
e.g. one SLSV,
Connection, FSL: Slave's own address
Connection, NSL: 1
Configuring
SIEMENS
SIMOVERT SC
6SE7016- 1EA 30
WR 2,2kW
Nr. 4 67321
4-39