Siemens SIMATIC FM 453 Getting Started

First steps in commissioning
Hide thumbs Also See for SIMATIC FM 453:

Advertisement

Quick Links

SIMATIC
FM 453
Getting Started
04/2007 Edition
First Steps in Commissioning

Advertisement

loading

Summary of Contents for Siemens SIMATIC FM 453

  • Page 1 SIMATIC FM 453 Getting Started 04/2007 Edition First Steps in Commissioning...
  • Page 2: Hardware And Software Requirements

    This Guide uses a specific example for channel 1 (axis 1) with servo drive or step drive with four ope- rational steps in successive order. These lead to a functioning application with which you can execute a traversing movement and familiarize yourself with and test the basic hardware and software func- tions of your FM 453.
  • Page 3 S Interface for OPs: “Siemens\Step7\EXAMPLES\FM453\zEn17_02_FM453_OP_EX” S User examples: “Siemens\Step7\EXAMPLES\zEn17_02” STEP7 project name: “zEn17_02_FM453_EX” S MD-DBs (startup of stepper motor control): “Siemens\Step7\EXAMPLES\FM453\MD” The installation of the configuring package is also described in Section 5.1 of the Manual. Parameterizing the FM 453 If you haven’t yet created a project, then proceed as follows:...
  • Page 4 Servo drive By clicking on the button in the overview window a new machine data data block (DB-MD) for channel 1 is opened. This DB MD is preset with default values (figure “Machine Data). With these default values and by configuring your plant as follows you can execute a traverse move- ment: S Power section: SIMODRIVE 611-A S Motor: 1FT5...
  • Page 5 If an error occurs during testing, you can reset by clicking the button Restart Ack. (Acknowledge) in the startup window. You can read the error message number and error message with the menu command Test → Alarms in the overview window. If you change machine data, you can activate these changes by clicking on the button MD active ter loading the FM.
  • Page 6: Further Examples

    After a successful startup of the CPU and the FM 453, the following values have been set by OB 100: S The “Jog” mode with the operating parameter BP = 1 (value of speed step 1) S Override 100 % S Servo enable is set S Velocity levels: 40 m/min (level 1) and 80 m/min (level 2) You can monitor the status of the FM module in the main display or by selecting...
  • Page 7 Siemens AG Automation and Drives 90437 Nuernberg E Siemens AG 1999-2007 Federal Republic of Germany Subject to change without prior notice A5E00059441-03 Siemens Aktiengesellschaft Printed in the Fed. Rep. of Germany...