Huawei Quidway S5300 Series Quick Start Manual

Huawei Quidway S5300 Series Quick Start Manual

Hide thumbs Also See for Quidway S5300 Series:
Table of Contents

Advertisement

Quidway S5300 Series Ethernet Switches
V100R002C02
Quick Start
Issue
01
Date
2008-12-26
Part Number
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei Quidway S5300 Series

  • Page 1 Quidway S5300 Series Ethernet Switches V100R002C02 Quick Start Issue Date 2008-12-26 Part Number Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
  • Page 2 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com...
  • Page 3: Table Of Contents

    Quidway S5300 Series Ethernet Switches Quick Start Contents Contents About This Document........................1 1 Quick Start...........................1-1 1.1 Introduction..............................1-2 1.1.1 Overview..............................1-2 1.2 S-switch Overview............................1-2 1.2.1 Appearance of the S5300........................1-2 1.3 Basic Configurations for the Device Management..................1-3 1.3.1 Example for Configuring to Manage the S-switch Through Telnet............1-3 A Equipment Grounding Specifications.................A-1...
  • Page 4 Quidway S5300 Series Ethernet Switches Contents Quick Start B.6 Engineering Labels for Power Cables......................B-19 B.6.1 Engineering Labels for DC Power Cables..................B-19 B.6.2 Engineering Labels for AC Power Cables..................B-21 Huawei Proprietary and Confidential Issue 01 (2008-12-26) Copyright © Huawei Technologies Co., Ltd.
  • Page 5 Quidway S5300 Series Ethernet Switches Quick Start Figures Figures Figure 1-1 Side view of the S5328C-EI.......................1-2 Figure 1-2 Front view of the S5328C-EI-24S......................1-2 Figure 1-3 Rear view of the S5352C-EI.......................1-3 Figure 1-4 Networking diagram of managing S-switch-A through Telnet............1-3 Figure B-1 Label for signal cables........................B-3 Figure B-2 Power Cable Label..........................B-4...
  • Page 7 Quidway S5300 Series Ethernet Switches Quick Start Tables Tables Table A-1 General Grounding Specifications.....................A-2 Table A-2 Equipment Grounding Specifications....................A-3 Table A-3 Grounding Specifications for Communication Power Supply............A-3 Table A-4 Grounding Specifications for Signal Cables..................A-4 Table A-5 Specifications for laying out grounding cables..................A-5 Table B-1 Standard Typeface for Handwriting....................B-6...
  • Page 9: About This Document

    Quidway S5300 Series Ethernet Switches Quick Start About This Document About This Document Purpose This part describes the organization of this document, product version, intended audience, conventions, and update history. Related Versions The following table lists the product versions related to this document.
  • Page 10 Quidway S5300 Series Ethernet Switches About This Document Quick Start Chapter Description A Equipment Grounding specifications include general grounding Grounding specifications, the grounding specifications for the equipment Specifications room, device, communication power modules, signal cables, signal cables, and the specification for laying out grounding cables.
  • Page 11 Quidway S5300 Series Ethernet Switches Quick Start About This Document Command Conventions Convention Description Boldface The keywords of a command line are in boldface. Italic Command arguments are in italics. Items (keywords or arguments) in brackets [ ] are optional.
  • Page 12 Quidway S5300 Series Ethernet Switches About This Document Quick Start Mouse Operation Action Description Click Select and release the primary mouse button without moving the pointer. Double-click Press the primary mouse button twice continuously and quickly without moving the pointer.
  • Page 13: Quick Start

    Quidway S5300 Series Ethernet Switches Quick Start 1 Quick Start Quick Start About This Chapter This section describes the hardware, installation procedure, and basic configurations of the device. 1.1 Introduction 1.2 S-switch Overview 1.3 Basic Configurations for the Device Management This section describes the basic configurations for the device management such as configuring IP addresses, remote login, naming the device, and setting device time.
  • Page 14: Introduction

    Quidway S5300 Series Ethernet Switches 1 Quick Start Quick Start 1.1 Introduction 1.1.1 Overview 1.1.1 Overview The Quidway S5300series switches are a series of Layer 2 line-rate Ethernet switches. They are intelligent and manageable, and applicable to the environments where high performance, high port density, and installation easiness are required.
  • Page 15: Basic Configurations For The Device Management

    Quidway S5300 Series Ethernet Switches Quick Start 1 Quick Start Appearance of the S5352C-EI The chassis of the S5352C-EI is 1 U high with the dimensions of 442.0 x 420.0 x 43.6 mm (width x depth x height).Figure 1-3 shows the rear view of the S5352C-EI.
  • Page 16 Quidway S5300 Series Ethernet Switches 1 Quick Start Quick Start Configuration Roadmap The configuration roadmap is as follows: Log in to S-switch-A through the console interface. Set the device name. Configure a management VLAN. On S-switch-A, set the type of the interface that connects S-switch-A and S-switch-B to trunk.
  • Page 17 Quidway S5300 Series Ethernet Switches Quick Start 1 Quick Start Verify the configuration. <S-switch-A> telnet 127.0.0.1 Trying 127.0.0.1 ... Press CTRL+T to abort Connected to 127.0.0.1 ... *********************************************************** All rights reserved (2000-2007) Without the owner's prior written consent, * no decompiling or reverse-engineering shall be allowed. * * Notice: This is a private communication system.
  • Page 19: A Equipment Grounding Specifications

    Quidway S5300 Series Ethernet Switches Quick Start A Equipment Grounding Specifications Equipment Grounding Specifications This describes grounding specifications, including general grounding specifications, the grounding specifications for equipment rooms, devices, communication power modules, signal cables, and the specification for laying out grounding cables.
  • Page 20: General Grounding Specifications

    Quidway S5300 Series Ethernet Switches A Equipment Grounding Specifications Quick Start A.1 General Grounding Specifications This describes the requirements of general grounding specifications in details. Table A-1 shows the general grounding specifications. Table A-1 General Grounding Specifications Description The design for grounding should follow the principles of equal voltage and equal potential.
  • Page 21: Grounding Specifications For Communications Power Supply

    Quidway S5300 Series Ethernet Switches Quick Start A Equipment Grounding Specifications Table A-2 Equipment Grounding Specifications Description All communication devices and auxiliary devices (such as mobile base stations, transmission and switching devices, power supply devices) in the equipment room should be grounded for protection. Connect all protection grounding for various devices jointly to a general grounding bar, and then to the same protection grounding bar in the room together with the protection ground (PGND) of the device.
  • Page 22: Grounding Specifications For Signal Cables

    Quidway S5300 Series Ethernet Switches A Equipment Grounding Specifications Quick Start Description The inlet for the AC power cable at the equipment room should be equipped with a lightning protection device (C-level) with a nominal discharging current no less than 20 kA.
  • Page 23: Specifications For Laying Out Grounding Cables

    Quidway S5300 Series Ethernet Switches Quick Start A Equipment Grounding Specifications Description The signal cables within the area of the communication office and mobile station should not be arranged aerially. A.6 Specifications for Laying Out Grounding Cables This describes the requirements for laying out grounding cables in details.
  • Page 25: B Engineering Labels For Cables

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Engineering Labels for Cables This gives you an overview of engineering labels and describes the engineering labels for optical fibers, Ethernet cables, and power cables. An engineering label serves as an identifier for on-site installation and maintenance after the installation.
  • Page 26: Introduction To Labels

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start B.1 Introduction to Labels This describes the material, types, structure, and contents of engineering labels, and how to print, fill in, and paste engineering labels, and the precautions for using engineering labels.
  • Page 27: Figure B-1 Label For Signal Cables

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Figure B-1 Label for signal cables To specify more clearly the position of a cable, use the dividing lines on the label. For example, there is a dividing line between the cabinet number and the chassis number, and another one between the chassis number and the slot number.
  • Page 28: Label Printing

    Download the template from http://support.huawei.com. Obtain the template from the Huawei local office. The templates are made in Microsoft Word and the following requirements should be met: When using the template, you can directly modify the contents on the template. The settings of centered characters, direction, and fonts should not be changed.
  • Page 29: Figure B-3 Warning Prompt Before Printing

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Select Edit/Select All. Select Format/Borders and Shading/Borders. Select Box tab and click OK. Drag the mouse to select cells to be merged and select the Table/Merge Cells. Requirements on the Printer To print the labels, laser jet printer must be used, although there is no restriction on the model of the printer.
  • Page 30: Writing Labels

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start All the printouts must be on the label, and nothing should be printed on the bottom page of the label. Contents in the cells should be aligned in the center. In a single-line printout, the dividing lines and the mark "To:"...
  • Page 31: Affixing Labels

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables B.1.5 Affixing Labels After printing or writing the label, remove the label from the bottom page and affix it to the signal cable, or the identification plate of the power cable. Method of affixing Labels: Label for Signal Cables Choose the place to affix labels.
  • Page 32: Figure B-6 Label For Signal Cables

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Figure B-6 Label for Signal Cables Power Cable Label Remove the label from the bottom page, and then affix it to the identification plate on the cable tie. Remove the label from the bottom page, and then affix it to the identification plate on the cable tie.
  • Page 33: Contents Of Engineering Labels

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Figure B-7 Binding the Label for the Power Cable B.1.6 Contents of Engineering Labels Contents of Labels for Power Cables Labels for power cables are only affixed on one side of the identification plates. On the labels, there is information (the part after the mark "TO:") about the location of the device on the other...
  • Page 34: Precautions For Using Engineering Labels

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Therefore, the information in Area 1 at one end is the same as the information in Area 2 at the other end of the cable. In other words, the local information at one end is called the opposite information at the other end.
  • Page 35 Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Content Meaning Example B: chassis Numbered in bottom-up order with two digits, for number example, 01. C: physical slot Numbered in the top-bottom and left-right order starting number from 01.
  • Page 36: Labels For The Optical Fibers Connecting The Device And An Odf

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Figure B-9 Example of the label on the optical fiber between two devices The meaning of the labels is listed in Figure B-9. “A0-01-05-01-R” indicates that the local end of the optical fiber is connected with the optical receiving interface 01 on slot 5, chassis 01 in the cabinet on row A, column 01 in the machine room.
  • Page 37: Engineering Labels For Network Cables

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Content Meaning Example ODF-MN-B- MN: row number M: The cabinet rows from front to back are numbered C-R/T and column from A to Z. number of an N: The cabinet columns from left to right are numbered from 01 to 99.
  • Page 38: Table B-4 Information On The Ethernet Cables

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Applicable Ranges The labels can be applied to Ethernet cables. Label Content Table B-4 shows the information on both sides of the labels affixed to the Ethernet cables.
  • Page 39: Engineering Labels For Trunk Cables

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables The serial number on the hub, the network interface number of the agent or terminal, and the location of the stand-alone router should be specified according to actual connections.
  • Page 40: Figure B-12 Engineering Labels For Trunk Cables Between Devices

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Table B-5 Contents of engineering labels for trunk cables between devices Content Meaning Example MN-B-C-D- MN: cabinet For example, A01. number B: chassis Numbered in the bottom-up order with two digits, for number example, 01.
  • Page 41: Engineering Labels For Trunk Cables Between The Device And A Ddf

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables “G01-01-05-01-T” indicates that the local end of the trunk cable is connected to transmitting interface 01 on slot 05, chassis 01 in the cabinet on row G, column 01 in the equipment room.
  • Page 42: Engineering Labels For User Cables

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Content Meaning Example DDF-MN-B- R: optical Usually, a DDF is marked with "A", which indicates that C-D/R/T receiving the DDF terminal is connected to an optical network interface, T: device or "B", which indicates that the DDF terminal is...
  • Page 43: Figure B-14 Example Of Labels For User Cables

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables Content Meaning Example C: physical slot Numbered with two digits in the top-bottom and left- number right order. For example, 01. D: cable number Numbered with two digits in the top-bottom and left- right order.
  • Page 44: Figure B-15 Example Of The Labels For Dc Power Cables

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start The labels for DC power cables are affixed to one side of the identification plates on cable ties. For details of the labels, see Table B-8. Table B-8 Contents of the label...
  • Page 45: Table B-9 Label Content

    Quidway S5300 Series Ethernet Switches Quick Start B Engineering Labels for Cables On the distribution box side, the label “B03--48V2” indicates that the cable is -48 V DC supply, connected to DC power socket 2 on row B, column 03 in the equipment room.
  • Page 46: Figure B-16 Labels For Ac Power Cables

    Quidway S5300 Series Ethernet Switches B Engineering Labels for Cables Quick Start Figure B-16 Labels for AC power cables Meaning of the label in Figure B-16. On the loaded cabinet side, the label “A01-AC” indicates that the power cable is connected to the socket of Row A and Column 01 in the machine room.

Table of Contents