SYSTEM DISPLAYS

This function programs the text display on the keypad for when the system is disarmed, or an area is armed. The
Site Name reference is programmed here which must match the site name programmed on the InSite software.
There are options to enable or disable displaying system status, alarms, hold ups or zones.
Area texts
This programs how each area will be displayed. For example if 'Area A' is used to arm the full house this can be text
as "Full House Set". There is a maximum of 16 characters on the display.
Sign on message
The Sign on Message is the main display on the top line in day mode.
Display when set, display alarms and display HUs (not compliant)
If 'Display when set' is enabled, then the area text will be displayed on the LCD keypad once the system is fully
armed. If 'Display Alarms / HUs' is enabled, the system will display any alarms that are activated before a valid
user code/tag is entered. If 'Display Inputs' is enabled, any zones activated in day mode will be displayed.

EXIT MODES

The 'Exit Modes' operate the arming procedure of the system. The following 'Exit Modes' are available:
[0] Timed
The system will arm when the programmed 'Exit Time' has expired.
Please note: This is NOT suitable for systems installed to comply with BS8243.
[1] Final Door
The system will arm when a zone programmed as 'Final Exit' is either closed (if the zone was opened when arming
started) or it is opened and closed. 'Final door' is used for the 'lock set' operation; securing the lock completes the
arming procedure and unlocking starts the entry time.
[2] Timed/Final
The system will arm when a 'Final Exit' zone has been closed, or when an 'Exit Time' has expired. The 'Final Exit' zone
will override any 'Exit Time' programmed if opened/closed.
Please note: This is NOT suitable for systems installed to comply with BS8243.
[3] Push to Set (PTS)
The system will only arm when a 'Push to Set' button has been pressed. This function will override the
programmed Exit Time.

REVIEW LOGS

REVIEW LOGS?

Panel Log

The Panel log records all events that occur on the system, i.e. Users entering their codes to arm or disarm areas,
alarm events, failures to arm etc. Pressing c will give more information of the display (for example, shows
which user disarmed the system).

Access Log

The Access log records all events for Access Control events.
With each log, use the d key to move from one event to the previous event. The b key will move from one
event to the next event that occurred.
30
Panel Log?
Access Log?
ENFORCER V11 PROGRAMMING GUIDE