Commissioning | A4... with HS5E(V)(L) control system Series 1x and 30
pressure value B (S-0-0804). Refer to chapter 7.6.8 on page 61 for the various
options for connecting a pressure transducer.
Fig. 24: Actual pressure value acquisition (example of open circuit with pressure transducer)
8.1.5.3 Setting of torque limitation
For torque limitation to be able to operate, it needs a valid actual pressure value
from a pressure sensor.
100% corresponds to the torque of the pump at the actually set maximum
displacement and to the value of pressure standardization.
or
To protect the drive motor from overloading, it is possible to limit the maximum
torque of the pump. Parameter "P-0-2952, Torque limitation of pump, relative" is
a relative variable in percent and is relative to the maximum torque of the pump at
normal pressure (P-0-2957.0.1).
RE 92076-01-B/2021-04-22, Bosch Rexroth AG
71/104
Need help?
Do you have a question about the rexroth HS5E and is the answer not in the manual?
Questions and answers