Application Guide
Symbio™ 700 Controller
with Odyssey Split Systems
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
June 2020
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
A A C C C C - - A A P P G G 0 0 0 0 1 1 A A - - E E N N

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Symbio 700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane Symbio 700

  • Page 1 Application Guide Symbio™ 700 Controller with Odyssey Split Systems S S A A F F E E T T Y Y W W A A R R N N I I N N G G Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training.
  • Page 2 E E Q Q U U I I P P M M E E N N T T A A R R E E P P R R O O P P E E R R L L Y Y R R A A T T E E D D F F O O R R I I N N T T E E N N D D E E D D V V O O L L T T A A G G E E . . ACC-APG001A-EN ©2020 Trane...
  • Page 3 N N o o n n - - T T r r a a n n e e p p e e r r s s o o n n n n e e l l s s h h o o u u l l d d a a l l w w a a y y s s f f o o l l l l o o w w l l o o c c a a l l r r e e g g u u l l a a t t i i o o n n s s . . Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.
  • Page 4: Table Of Contents

    Symbio 700 Overview ........
  • Page 5 T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Leaving Service Test Mode ..........27 Constant Volume Supply Fan Service Test Mode .
  • Page 6 T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Internal and External Space Setpoint Adjustment ......42 ACC-APG001A-EN...
  • Page 7: Introduction

    Introduction The Symbio 700 installed on Odyssey split systems is a factory installed and programmed controller, providing digital control and protection of the equipment. The Symbio 700 has two model options: • S S t t a a n n d d a a r r d d C C o o n n f f i i g g u u r r a a t t i i o o n n — provides standard troubleshooting via on-board user interface (UI) and access to the Symbio Service and Installation mobile app.
  • Page 8: Symbio 700 Overview

    Symbio 700 Overview Field Connection The Symbio 700 controller optimizes inputs and outputs (I/O) for multiple applications. For initial installation of an Odyssey with Symbio 700, the field landed inputs are outlined below. Figure 1. Symbio 700 Field Connections Table 1. Field Connections...
  • Page 9: Unit Configuration

    The interface provides an intuitive menu structure: alarms, status, service, settings, and utilities. Configuration of the unit is accomplished under the utilities menu item. A complete list of functions is outlined in the Symbio 700 User Guide - BAS-SVU054. ACC-APG001A-EN...
  • Page 10: Mobile Application

    The Trane Symbio™ Service and Installation mobile app is required to setup, edit, and confirm the communication protocol and associated settings. The free download of Trane Symbio Service and Installation mobile app is available on the App Store® for iOS, and on Google Play® for Android™.
  • Page 11 4. Start the mobile app on your smart device. 5. On the login screen, press S S k k i i p p in the lower right-hand corner of the screen. Or Trane personnel can login using their Trane Connect username and password.
  • Page 12 I I m m p p o o r r t t a a n n t t : : To keep the list of previously-connected devices manageable, the Bluetooth smart devices list is limited to 10 devices. When 10 or more Bluetooth devices are defined on the smart device, connection to the Symbio 700 controller is not allowed. •...
  • Page 13: Startup Sequence

    Startup Sequence Under normal conditions, the Symbio 700 will startup over approximately 60 seconds once power is applied to the system. During this process, the controller checks that a valid system configuration is present and proceeds to normal control operation. After startup, the system will begin to respond to operational requests.
  • Page 14: Conventional Thermostat Sequence Of Operation

    Conventional Thermostat Sequence of Operation When the Odyssey system is configured to operate with a conventional thermostat, the controller provides protection for the system (see General Support Sequence section) and continues to provide insight to operating conditions. A conventional thermostat can be applied with constant volume cooling only, heat pump, and single zone 2-speed fan configured systems.
  • Page 15 C C o o n n v v e e n n t t i i o o n n a a l l T T h h e e r r m m o o s s t t a a t t S S e e q q u u e e n n c c e e o o f f O O p p e e r r a a t t i i o o n n ACC-APG001A-EN...
  • Page 16: Space Temperature Control Sequence Of Operation

    Constant Volume and Multi-Speed Fan Configuration Normal Operation The Symbio 700 has a single-loop (space temperature only) control sequence. The sequence is PI-based (proportional, integral) and strives to maintain space temperature within 1F of the active cooling and heating setpoints.
  • Page 17: Single Zone Variable Air Volume

    Discharge Air Temperature Setpoint Active setpoint. VVZT DAT Control Mode With the Symbio 700 VVZT control sequence, the end user can choose to use the internally derived Discharge Air Temperature Setpoint Active or to override the value with their own.
  • Page 18 S S p p a a c c e e T T e e m m p p e e r r a a t t u u r r e e C C o o n n t t r r o o l l S S e e q q u u e e n n c c e e o o f f O O p p e e r r a a t t i i o o n n If the VVZT DAT Control Mode –...
  • Page 19: General Support Sequences

    When a system is equipped with a VFD, the minimum and maximum VFD parameters can be adjusted to tune the airflow to meet the application requirements. In addition to this, the Symbio 700 supports setpoints that can adjust airflow as needed: •...
  • Page 20: Compressor Low Pressure Cutout Control

    For each compressor/circuit, a normally CLOSED low pressure cutout input is monitored for equipment protection on the Symbio 700. When a low pressure event is active, the input becomes OPEN and diagnostics are generated as described below. Refer to the Diagnostics section below for specific diagnostics that are generated based on the circuit Low Pressure Cutout inputs.
  • Page 21: Heat Pump Support Sequences

    Heat Pump Support Sequences Heat Pump Switchover Valve The Switchover Valve function is only applicable to Heat Pump units. Depending on the refrigeration system configuration for a unit, it may have one or two switchover valves. Additionally, some units with two switchover valves could control each valve independently while others will control in tandem.
  • Page 22: Evaporator Defrost Control

    H H e e a a t t P P u u m m p p S S u u p p p p o o r r t t S S e e q q u u e e n n c c e e s s compressor operation.
  • Page 23: Building Automation System Support Sequences

    It also provides a mechanism to return the system to unoccupied mode when the space is no longer occupied. There are two methods of requesting or terminating timed override on a Symbio 700 control system: •...
  • Page 24: Unit Stop

    B B u u i i l l d d i i n n g g A A u u t t o o m m a a t t i i o o n n S S y y s s t t e e m m S S u u p p p p o o r r t t S S e e q q u u e e n n c c e e s s function to prevent excessively cold discharge air from being supplied from the unit.
  • Page 25: Remote Capacity Control

    Remote Capacity Control The Symbio 700 controls support the Remote Capacity Control function, which allows a user to directly control the unit capacity rather than allowing the internal algorithm to provide control. The following features/functions can be requested directly via points, rather than relying on internal temperature or thermostat control sequences: •...
  • Page 26: Emergency Override

    For the case where the unit is required to turn Off via hardwired interface, the Equipment Shutdown input is used. Emergency Override All units with Symbio 700 support the remote Emergency Override Command functionality. Within this point, there are addition enumerations versus the hardware Ventilation Override interface: •...
  • Page 27: Service Test Mode

    The tables describe the service test mode states and expected unit response. For all service test mode operation, “IN CONTROL” refers to Symbio 700 control algorithms controlling the unit. For instance, in all service test mode states, the Condenser Fan will be controlled as needed to ensure safe unit operation.
  • Page 28: Multi-Speed Supply Fan Service Test Mode

    S S e e r r v v i i c c e e T T e e s s t t M M o o d d e e Table 4. Cooling Only (continued) Inactive IN CONTROL IN CONTROL IN CONTROL IN CONTROL IN CONTROL...
  • Page 29: Variable Speed Supply Fan Service Test Mode

    S S e e r r v v i i c c e e T T e e s s t t M M o o d d e e Table 6. Cooling only (continued) Inactive IN CONTROL IN CONTROL IN CONTROL IN CONTROL IN CONTROL...
  • Page 30 S S e e r r v v i i c c e e T T e e s s t t M M o o d d e e Table 8. Cooling only (continued) Inactive IN CONTROL IN CONTROL IN CONTROL IN CONTROL IN CONTROL...
  • Page 31: Diagnostics

    Diagnostics Device Tracker Symbio 700 will keep statistical data of the unit for component starts and component run times (in hours) for the following unit components: • Compressor 1 • Compressor 2 • Condenser Fan 1 • Condenser Fan 2 •...
  • Page 32: Diagnostic: Compressor X Contactor Failure

    D D i i a a g g n n o o s s t t i i c c s s • The “Diagnostic: Compressor X Proving Lockout” diagnostic point is activated and the alarm output is activated. Diagnostic: Compressor X Contactor Failure If a compressor proving input becomes Active for 5 continuous seconds when the associated compressor command output is Inactive, a Diagnostic: Compressor X Contactor Failure is generated and the following occurs:...
  • Page 33: Diagnostics - Alarm Indicator Status

    Customer Connection Module. This point is set to active when a failure occurs that functionally stops a critical component within the HVAC system. For a list of all supported Symbio 700 Diagnostics and if it sets the Alarm Indicator, refer to the Appendix section of this document.
  • Page 34: Troubleshooting

    (SZVAV) Sensor Fault On Symbio 700, if a sensor value goes outside of its minimum or maximum range, the point goes into an Alarm State. If the point in the Alarm State, we consider the sensor failed and take the...
  • Page 35: Compressor Fault

    Space CO2 Sensor Annunciated in the Active Alarm list. Auto Reset Compressor Fault Symbio 700 supports compressor safety functionality to keep the compressors from operating in an undesirable condition. If a compressor safety failure occurs, the following actions occur: Response Type Fault...
  • Page 36: Defrost Fault

    T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g Defrost Fault The below list of diagnostics are associated with the Demand Defrost Function. Response Fault Fault Detection Symbio 700 Response Type Diagnostic: Demand Manual • Set Diagnostic: •...
  • Page 37 T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g Response Fault Fault Detection Symbio 700 Response Type Diagnostic: Demand ∆T does not change by 2°F Manual •...
  • Page 38: Supply Fan

    Appendix A Supply Fan Multi-Speed/VFD Table 10. Multi-speed minimum supply fan speeds Unit Operation Supply Fan Speed Fan Only 41.7% Cooling Stage 1 41.7% Cooling Stage 2 100% Heat Pump Heating 100% Electric/Auxiliary Heating 100% Variable Speed/VFD Table 11. Variable speed minimum supply fan speeds Unit Operation Supply Fan Speed Fan Only...
  • Page 39: Heat Pump - Cvzt & Vvzt

    A A p p p p e e n n d d i i x x A A Table 14. Dual unloading compressor cooling staging Unit Operation Unit Response Cooling Stage 1 Compressor 1 Output ON + Compressor 2 Output ON Cooling Stage 2 Compressor 1 Output ON +Compressor 1 Unloader Solenoid ON + Compressor 2 Output...
  • Page 40: Electric Heat

    A A p p p p e e n n d d i i x x A A N N o o t t e e s s : : • If Defrost is active on Heat Pump refrigeration circuit 1, then unit response is Condenser Fan Output 1 OFF.
  • Page 41: Emergency And Ventilation Override

    A A p p p p e e n n d d i i x x A A Table 21. Odyssey supported diagnostics and alarm relay functionality (continued) Diagnostic/Alarm Alarm Indicator Diagnostic: Circuit 2 LPC Lockout Diagnostic: Compressor 1 Proving Lockout Diagnostic: Compressor 2 Proving Lockout Diagnostic: Compressor 1 Contactor Failure Diagnostic: Compressor 2 Contactor Failure...
  • Page 42 A A p p p p e e n n d d i i x x A A Internal and External Space Setpoint Adjustment Zone sensors with an internal or external setpoint adjustment provide the controller with a local setpoint (50° F to 85° F or 10° C to 29.4° C). The internal setpoint adjustment is concealed under the zone sensor cover.
  • Page 43 N N o o t t e e s s ACC-APG001A-EN...
  • Page 44 For more information, please visit trane.com or tranetechnologies.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

Table of Contents

Save PDF