About this document Liquiline Mobile CML18 About this document Warnings Structure of information Meaning This symbol alerts you to a dangerous situation. DANGER Failure to avoid the dangerous situation will result in a fatal or serious injury. Causes (/consequences) If necessary, Consequences of non- compliance (if applicable) ‣...
The battery may only be changed directly at the manufacturer' s premises or by the service organization. Designated use The Liquiline Mobile CML18 is a multiparameter mobile device for the connection of digital sensors with Memosens technology and optional operation by smartphone or other mobile devices via Bluetooth.
Liquiline Mobile CML18 Basic safety instructions Ensure that electrical cables and hose connections are undamaged. Do not operate damaged products, and protect them against unintentional operation. Label damaged products as defective. During operation: ‣ If faults cannot be rectified: products must be taken out of service and protected against unintentional operation.
Product description Liquiline Mobile CML18 Product description Product design A0040968 1 CML18 Protection cap Display screen with automatic screen rotation "Select" button "Next" button Memosens connection Area for wireless charging Status LED M12 connection Endress+Hauser...
Page 9
Liquiline Mobile CML18 Product description 3.1.1 Measuring parameters The mobile device is designed for digital Memosens sensors with an inductive plug-in head and fixed cable sensors with the Memosens protocol and no external power supply: • pH • ORP • pH/ORP combination sensors •...
Incoming acceptance and product identification Liquiline Mobile CML18 Incoming acceptance and product identification Incoming acceptance Verify that the packaging is undamaged. Notify the supplier of any damage to the packaging. Keep the damaged packaging until the issue has been resolved.
Dieselstraße 24 D-70839 Gerlingen Scope of delivery The scope of delivery comprises: • 1 Liquiline Mobile CML18 • 1 set of Operating Instructions in German • 1 set of Operating Instructions in English Inductive charger and power unit are available separately.
Page 12
Incoming acceptance and product identification Liquiline Mobile CML18 complies with the safety requirements for portable RF exposure in accordance with FCC rule part §2.1093 and KDB 447498 D01. Canada radio approval IC ID: 22173-BT41PMMA01 This device complies with ISED’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference;...
Page 13
Liquiline Mobile CML18 Incoming acceptance and product identification Singapore radio approval Complies with IMDA Standards DA 108204 A0044087 Brazil radio approval 11739-20-11036 A0044179 Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.
Page 14
Incoming acceptance and product identification Liquiline Mobile CML18 South Korea radio approval A0039065 R-R-E1H-CML18 Mexico radio approval A0034100 Número IFETEL: RCPENCM20-2345 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.
Page 15
Liquiline Mobile CML18 Incoming acceptance and product identification Australia radio approval A0044970 Endress+Hauser...
Electrical connection Liquiline Mobile CML18 Electrical connection Connecting the sensor 5.1.1 Connecting the Memosens sensor directly A0040973 2 Sensor connection Insert the sensor into the Memosens connection. Click the Memosens connection into place. 5.1.2 Connecting the Memosens sensor with M12 fixed cable connection...
Liquiline Mobile CML18 Electrical connection 5.1.3 Connecting the sensor via the Memosens M12 cable The M12 cable has two different connectors: • M12 connector for connecting to the device • Memosens connection for connecting a Memosens sensor A0040974 A0040972 A0041005 ...
Page 18
Electrical connection Liquiline Mobile CML18 The following applies to both options: • When device is switched on: • The start of charging is indicated by a flash symbol on the display and confirmed by an acknowledgment tone. • If charging stops before the battery is fully charged, this is confirmed by another acknowledgment tone.
Liquiline Mobile CML18 Electrical connection An acoustic signal indicates that charging is complete. During inductive charging, measurement via the integrated Memosens connection on the device is not possible. A message to this effect is shown on the display. Measurement via M12 cable is still possible.
Operation options Liquiline Mobile CML18 Operation options Overview of operation options Operation and settings via: • Internal operating menu with keys • SmartBlue App via Bluetooth® LE wireless technology → 23 6.1.1 Display and operating elements A0040996 5...
Page 21
Liquiline Mobile CML18 Operation options Application Data logger Data logger Log interval Cond. unit Erase data Erase continuous logs Abort Erase Erase grab values Abort Erase Diagnostics Diagnostics list Data logger entries Display test Device info Manufacturer Software version Serial number...
Page 22
Operation options Liquiline Mobile CML18 Guidance 2 point calibration Available only with pH or ISFET sensor Display structure A0044047 6 Schematic representation of the display structure Menu path/title of measuring screen Bluetooth status Battery level, charging information NAMUR indicator...
Page 23
Liquiline Mobile CML18 Operation options Structure of the measurement window The measurement window has 3 measuring screens, which the user can scroll through: Measuring screen (1 of 3) Measuring screen (2 of 3) Measuring screen (3 of 3) Main value...
Page 24
Operation options Liquiline Mobile CML18 A0029747 8 SmartBlue App icon Bluetooth must be enabled on both devices. Enable Bluetooth → 28 A0044142 9 SmartBlue App Livelist The Livelist displays all of the devices that are within range.
Page 25
Liquiline Mobile CML18 Operation options User name >> admin Initial password >> device serial number Change the user name and password after logging in for the first time. The current measured values are displayed in the Home view. The device information (device tag, serial number, firmware version, order code) is also displayed.
Page 26
Operation options Liquiline Mobile CML18 CML18_M41073505G11 A0041294 11 Main menus of the SmartBlue App Guidance Diagnostics Application System Menu Function Guidance Contains functions involving a self-contained sequence of activities, e.g. for calibration (= "Wizard", guided operation). Diagnostics Contains information regarding operation, diagnostics and troubleshooting, as well as the configuration of the diagnostic behavior.
Liquiline Mobile CML18 Commissioning Commissioning Preparatory steps Charge the device fully before initial commissioning.→ 16 Connect the sensor.→ 16 Function check WARNING Connection errors The safety of people and of the measuring point is at risk! ‣ Put the device into operation only if you can answer yes to all the following questions.
Commissioning Liquiline Mobile CML18 Setting the display language Navigate to: Display language Main menu >> System >> Display language Press to scroll through the predefined values. Description of setting Configuration options Change the language of the operating menu. • Deutsch •...
Page 29
Liquiline Mobile CML18 Commissioning Press to scroll through the predefined values. The following energy settings are available: • Power save w. charger (power saving with charger) • Power save w/o charger (power saving without charger) • Power-off w. charger (power off with charger) •...
Page 30
Commissioning Liquiline Mobile CML18 Power-off w/o charger (power off without charger) Function description Configuration options Set the time until the device switches off automatically if it is running on the • 1 min battery. • 5 min • 15 min •...
Page 31
Liquiline Mobile CML18 Commissioning Description of setting Configuration options Set the display brightness • Low • Medium • High • Maximum 7.6.6 Emergency restart This type of restart should only be performed in an emergency if the device does not respond to any other input.
Page 32
Commissioning Liquiline Mobile CML18 Enabling/disabling the data logger Navigate to: Data logger Main menu >> Application >> Data logger >> Data logger Press to scroll through the predefined values. Description of setting Configuration options Enable/disable automatic data logger • On •...
Liquiline Mobile CML18 Operation Operation Two-point calibration (pH or ISFET sensor) For two-point calibration of pH or ISFET sensors, the calibration settings are configured via the SmartBlue App. The calibration can then be started from the device. Configuring the calibration settings: Enable Bluetooth.
Page 34
Operation Liquiline Mobile CML18 8.2.2 Changing the sample IDs The 10 pre-set IDs for samples can be changed via the SmartBlue App. Preparatory steps Enable Bluetooth. → 28 Link the device to a mobile terminal device via the SmartBlue App. → 23 Transferring the data Select the device in the SmartBlue App.
Page 35
Liquiline Mobile CML18 Operation A0042257 Select Guidance. A0042258 Select Data transfer. Endress+Hauser...
Page 36
Operation Liquiline Mobile CML18 A0042261 Select Next to continue. A0042260 Endress+Hauser...
Page 37
Liquiline Mobile CML18 Operation Select Data source. Select Grab sample logger for saved samples. Select Cont. data logger for data records of the data logger. Press Ok to confirm. Select to discard changes and close the selection menu.
Page 38
Operation Liquiline Mobile CML18 A0042265 12. Use Share ZIP file... to save the exported data records locally or to send them. 13. Select Finish to complete the export. Exporting to a computer Preparatory steps: ‣ Download the CML18 readout tool to the target computer and save it.
Page 39
Liquiline Mobile CML18 Operation Elements of the export file Data logger export file Grab sample export file Elements in the general information section of the export Elements in the general information section of the export file: file: • Filename • Filename •...
Page 40
Operation Liquiline Mobile CML18 Description of the individual elements of the export files PV unit Unit of the primary value. SV name Name of the secondary value. SV value Numerical display of the secondary value of the logged entry. SV unit Unit of the secondary value.
During a firmware update, do not switch off the device manually or disconnect it from the mobile terminal. A video clip with instructions on how to perform a firmware update is available on Endress+Hauser' s Youtube channel via the following link or QR code: Firmwareupdate CML18 A0045926 ...
Page 42
Firmware update Liquiline Mobile CML18 Select System. Select Firmware update. Search for the available firmware update package on the terminal device and select it. If the update is not displayed, the firmware update package must be opened once using the SmartBlue App.
Liquiline Mobile CML18 Diagnostics and troubleshooting Diagnostics and troubleshooting 10.1 Diagnostics information via the onsite display 10.1.1 Opening the diagnostics list Navigate to: Diagnostics list Main menu >> Diagnostics >> Diagnostics list Press to open the diagnostics list. 10.1.2...
Maintenance Liquiline Mobile CML18 Maintenance 11.1 Maintenance tasks 11.1.1 Cleaning ‣ Only clean with a damp cloth and commercially available cleaning agents. The device is resistant to: • Ethanol (for a short time) • Soap-based household cleaning agents • Dishwashing detergent...
(WEEE), the product is marked with the depicted symbol in order to minimize the disposal of WEEE as unsorted municipal waste. Do not dispose of products bearing this marking as unsorted municipal waste. Instead, return them to Endress+Hauser for disposal under the applicable conditions.
Page 46
Accessories Liquiline Mobile CML18 www.endress.com/CML18 Optional charger: • Qi certification • 5 W output power • China RoHS conformity (50) A0046093 Endress+Hauser...
Liquiline Mobile CML18 Technical data Technical data 14.1 Input 14.1.1 Input power Wireless charging M12 connection 5 V; 0.6 A 14.1.2 Measured variables • pH • ORP • pH/ORP • Oxygen • Conductivity • Temperature 14.1.3 Measuring range → Documentation of the connected sensor 14.1.4...
Technical data Liquiline Mobile CML18 14.3.4 Overvoltage protection IEC 61 000-4-4 with 0.6 kV IEC 61 000-4-5 with 2.0 kV 14.3.5 Sensor connection Sensors with Memosens technology 14.3.6 Cable specification Digital measuring cable CYK10-Axx2+x Digital measuring cable CYK20-AAxxC1 M12 USB data cable 14.4...
Liquiline Mobile CML18 Technical data • Europe • USA • China • Canada • Japan • South Korea • Brazil • Mexico • Singapore • Argentina • Thailand • Australia • Indonesia 14.5 Mechanical construction 14.5.1 Dimensions 54 (2.13) A0044044 ...
Page 50
Technical data Liquiline Mobile CML18 14.5.2 Materials Components Material Housing Display window, light guide PMMA Buttons, cap M12 connection CuZn, nickel-plated 14.5.3 Materials not in contact with the medium Information according to REACH Regulation (EC) 1907/2006 Art. 33/1: The device battery contains the SVHC 1.3 propane sulton ; ethylene glycol dimethyl ether (CAS number 110-71-4) with more than 0.1% (w/w).