3.7.
Position unit according to safety instructions in Section 1.
3.8.
Open lid and place the pump control box through the
rectangular hole on the side of tub.
3.9.
Screw the 90° connector into the welded bolt on pump
housing, then fit the flexible tube to the 90° connector.
3.10.
Place the work shelf onto the welded supports inside the tank.
3.11.
Check that the tank drain plug is correctly inserted and
tightened.
3.12.
Place the parts basket on work shelf. Check your installation
to ensure the unit is ready for connecting to the air supply.
4.
AIR SUPPLY
fig.2
4.1.
ensure that the tank air valve is closed before connecting the
air supply.
4.2.
An air pressure of 65-125psi and an available air volume of
8-10cfm will be required to operate the unit.
WARNING! Ensure air supply is clean and does not
exceed 125psi. Too high an air pressure and/or unclean
air will shorten the product life due to excessive wear,
and may be dangerous, causing possible damage and/or
personal injury. Air supply must be equipped with
regulator, water trap and oiler.
4.3.
drain the air supply tank daily. Water in the air line will
damage the unit.
4.4.
Clean the air supply filter weekly. For recommended hook-up,
see fig.2 above.
4.5.
line pressure should be increased to compensate for
unusually long air hoses (over 8 metres). The minimum hose
internal diameter should be 10mm and fittings must have the
same internal dimension.
4.6.
Keep hose away from heat, oil and sharp edges. Check
hoses for wear, and make certain that all connections are
secure.
4.7.
The air inlet connection is 1/4"BSP.
5. OPERATING INSTRUCTIONS
WARNING! Read and apply Section 1 safety instructions
before using the cleaning tank.
5.1.
Check the air regulator valve (fig 3.1) is off, and air inlet (2) is
disconnected from the air supply.
5.2.
Fill the tank to appropriate capacity (See specifications) with
Sealey solvent, or a general purpose degreaser (contact your
local dealer for supply). dO NOT use any other type of
solvent. CAUTION! Ensure you follow any instructions
provided with the solvent.
5.3.
Connect washer to the air supply, aim flexible nozzle (3) into
tank and turn valve (1) on. Check that solvent flows freely
through the flexible nozzle.
5.4.
Place parts to be cleaned into the cleaning basket. direct
spray nozzle onto parts. ensure any splash back stays inside
the tank, if not reposition the spray nozzle. Adjust the air flow
valve (1) so that the minimal amount of output is generated
according to the task.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
5.5.
5.6.
5.7.
5.8.
5.9.
6. SOLVENT REPLACEMENT
6.1.
6.2.
6.3.
7. MAINTENANCE
7.1.
7.2.
7.3.
7.4.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. edmunds, Suffolk,
IP32 7AR
Original Language Version
The supplied brush may
be attached to the nozzle
to assisted cleaning if
required.
For stubborn and ground
in marks, leave the parts
to soak in the bottom of
the tank. Place the turbo
nozzle (7) in the solvent
and turn the turbo mode
valve (5) on. This will
agitate the solvent
and assist cleaning.
When parts are clean,
turn off the pump and
leave the parts to drain in
the basket or on the shelf.
To assist drying the air blow gun (4) may be used.
When complete turn the washer off and disconnect from the
air supply.
When cleaning parts ensure that nothing in the tank,
including any parts basket, is in a position that would
prevent the lid from closing fully if and when the fusible
link activates.
WARNING! It is operator's responsibility to ensure that
there is no uncontrolled discharge of any fluids used with
this unit and that appropriate arrangements have been
made for correct disposal of waste in accordance with
government/local authority regulations.
WARNING! Disconnect the air supply from the unit before
changing accessories, servicing or performing any
maintenance.
WARNING! Wear approved safety gloves, goggles, mask
and suitable clothing.
To empty used solvent, loosen sediment in the bottom of the
tank by use of the turbo mode, then open base plug to drain.
Completely drain dirty solvent into appropriate receptacle. Clean
inside of tank and strainer before refilling with clean solvent.
Store the used solvent in accordance with regulations.
Wipe up any spillage immediately.
WARNING! Disconnect the air supply from the unit before
changing accessories, servicing or performing any
maintenance.
Keep the cleaning tank clean. Remove and clean the filter
(fig 3.6) regularly for best and safest performance.
Regularly check and top up the oil in the air supply oiler.
Keep the outside of the unit clean.
dO NOT modify or jam the parts washer lid open, as this will
make the fusible fire link inoperative which is dangerous
practice and will invalidate the warranty and your insurance.
01284 757500
01284 703534
fig.3
www.sealey.co.uk
Web
sales@sealey.co.uk
email
SM221, SM223
Issue: 5 - 05/11/09

Advertisement

loading

This manual is also suitable for:

Power products sm223