Download Print this page
NEUTRIK powerCON TRUE1 Operating & Assembly Instruction

NEUTRIK powerCON TRUE1 Operating & Assembly Instruction

Advertisement

Quick Links

R
OPERATING & ASSEMBLY INSTRUCTION
NAC3MX-W
A. OPERATING INSTRUCTION
Application:
The powerCON TRUE1 system is certified as connector with breaking capacity according IEC 60320,
VDE 0625. It is intended for use as appliance couplers and interconnection couplers. It serves to
supply power to an appliance and from an appliance to another equipment. To be installed by qualified
person only.
Connector Assignment:
APPLIANCE INLET
NAC3MPX
Power IN
NAC3FX-W
(Connector)
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
B. ASSEMBLY INSTRUCTION
A
Insert cable into the
bushing and housing.
Note: "Apply cable
pulling lubricant to
cable jacket."
C
Place chuck over the
cable.
D
Prepare cable as
shown.
BDA 380
All manuals and user guides at all-guides.com
|
powerCON TRUE1
APPLIANCE OUTLET
Power OUT
NAC3MX-W
(Plug connector)
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A
2
H05VV-F3G 1.0 mm
, Length max. 2 m
H05VV-F3G 1.5 - 2.5 mm
2
H07RN-F3G 1.5 mm
2
White chuck
6.0 - 12.0 mm
B
C
20 mm
[0.787"]
PE 23 mm
VDE (EN 60320-1/EN60320-2-2)
NAC3FPX
NAC3PX
NAC3FPX-ST
Power IN
NAC3FX-W
(Connector)
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White chuck
6.0 - 12.0 mm
Separate the
housing from the
bushing (cable
remain in bushing)
8 mm
[0.32"]
[0.9"]
UL (UL 498 / CSA C22.2 No. 182.3)
APPLIANCE
INLET
OUTLET
COMBINATION
Power OUT
NAC3MX-W
(Plug connector)
20 mm
[0.787"]
8 mm
[0.32"]
PE 23 mm
[0.9"]
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the powerCON TRUE1 and is the answer not in the manual?

Questions and answers

Summary of Contents for NEUTRIK powerCON TRUE1

  • Page 1 A. OPERATING INSTRUCTION Application: The powerCON TRUE1 system is certified as connector with breaking capacity according IEC 60320, VDE 0625. It is intended for use as appliance couplers and interconnection couplers. It serves to supply power to an appliance and from an appliance to another equipment. To be installed by qualified person only.
  • Page 2 T: +91 / 982 05 43 424 F: +91 / 22 26163 540 Draft. Nr.: BDA 380 Update: 08.04.2014 ® ® Data subject to change without prior notice. © 2014 NEUTRIK . ALL RIGHTS RESERVED. NEUTRIK are registered trademark. www.neutrik.com...

This manual is also suitable for:

Nac3mx-w