Tx Uhf Lo - Nokia RH-66 Troubleshooting Manual

Rf description and troubleshooting
Hide thumbs Also See for RH-66:
Table of Contents

Advertisement

Nokia Customer Care
Figure 31
shows the Rx VHF LO test points.
Table 12
gives the description and values for the test points as shown in
Test
Point
1
2
3

Tx UHF LO

There are two fixed LOs: 3296.16~3395.88 MHz for Cell band and 3700~3819.90 MHz
for PCS band. This is the first LO for up-conversion. Monitor the control voltage at
C7014. At this control voltage, the N7000 LO is locked and should be between 1.2 and
1.8 VDC.
Issue 1 03/2005
1
Figure 31: Rx VHF LO test points
Table 12: Rx VHF LO Test Points
Description
RX LO lock voltage
VR7
VR5
©2005 Nokia Corporation
2115i/2116/2116i (RH-66)
RF Description and Troubleshooting
2
3
Value
1.2 to 1.7 VDC
2.8V
2.8V
Company Confidential
Figure
31.
Page 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

2115i21162116i

Table of Contents