Delta DX-2100 Series User Manual

Delta DX-2100 Series User Manual

Industrial 3g cloud router
Hide thumbs Also See for DX-2100 Series:
Table of Contents

Advertisement

Quick Links

Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
No.18, Xinglong Rd., Taoyuan City,
Taoyuan County 33068, Taiwan
TEL: 886-3-362-6301 / FAX: 886-3-371-6301
Asia
Delta Electronics (Jiangsu) Ltd.
Wujiang Plant 3
1688 Jiangxing East Road,
Wujiang Economic Development Zone
Wujiang City, Jiang Su Province, P.R.C. 215200
TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290
Delta Greentech (China) Co., Ltd.
238 Min-Xia Road, Pudong District,
ShangHai, P.R.C. 201209
TEL: 86-21-58635678 / FAX: 86-21-58630003
Delta Electronics (Japan), Inc.
Tokyo Office
2-1-14 Minato-ku Shibadaimon,
Tokyo 105-0012, Japan
TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211
Delta Electronics (Korea), Inc.
1511, Byucksan Digital Valley 6-cha, Gasan-dong,
Geumcheon-gu, Seoul, Korea, 153-704
TEL: 82-2-515-5303 / FAX: 82-2-515-5302
Delta Electronics Int'l (S) Pte Ltd.
4 Kaki Bukit Ave 1, #05-05, Singapore 417939
TEL: 65-6747-5155 / FAX: 65-6744-9228
Delta Electronics (India) Pvt. Ltd.
Plot No 43 Sector 35, HSIIDC
Gurgaon, PIN 122001, Haryana, India
TEL : 91-124-4874900 / FAX : 91-124-4874945
Americas
Delta Products Corporation (USA)
Raleigh Office
P.O. Box 12173,5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3800 / FAX: 1-919-767-8080
Delta Greentech (Brasil) S.A.
Sao Paulo Office
Rua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista
01332-000-São Paulo-SP-Brazil
TEL: 55 11 3568-3855 / FAX: 55 11 3568-3865
Europe
Delta Electronics (Netherlands) B.V.
Eindhoven Office
De Witbogt 20, 5652 AG Eindhoven, The Netherlands
TEL : +31 (0)40-8003800 / FAX : +31 (0)40-8003898
*We reserve the right to change the information in this manual without prior notice.
DX-2100 Series Industrial
3G Cloud Router
User Manual
DIACloud Cloud Platform
DX-020BB20-02
2020-05-14
www.deltaww.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DX-2100 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta DX-2100 Series

  • Page 1 1511, Byucksan Digital Valley 6-cha, Gasan-dong, DX-2100 Series Industrial Geumcheon-gu, Seoul, Korea, 153-704 TEL: 82-2-515-5303 / FAX: 82-2-515-5302 Delta Electronics Int’l (S) Pte Ltd. 3G Cloud Router 4 Kaki Bukit Ave 1, #05-05, Singapore 417939 TEL: 65-6747-5155 / FAX: 65-6744-9228 Delta Electronics (India) Pvt.
  • Page 2 DX-2100 Series Industrial 3G Cloud Router User Manual Revision History Version Revision Date 2016/3/21 The first version was published. 1. Add new function of Cloud Service for Auto Detect in section 3.2.1. 2. Chapter 3: Add new function of PIN Management in Section 3.2.2.
  • Page 4: Table Of Contents

    DX-2100 Series Industrial 3G Cloud Router User Manual Table of Contents Chapter 1 Introduction Product Overview ..................1-3 1.1.1 Network Design ..................1-4 1.1.2 Features ....................1-4 1.1.3 Front Panel Ports and LEDs ..............1-5 1.1.4 Top Panel ..................... 1-5 1.1.5...
  • Page 5 3.2.1 Cellular Network Configurations ............... 3-8 3.2.2 PIN Management ................. 3-11 3.2.3 LAN Configurations ................3-14 3.2.4 Static Routing Rules ................3-16 3.2.5 Dynamic DNS ..................3-18 Firewall ....................3-19 3.3.1 Firewall Settings .................. 3-19 3.3.2 DMZ Settings ..................3-19 3.3.3 Port Forward ..................
  • Page 6 Chapter 4 DIACom Introduction to DIACom ................4-2 4.1.1 Select a Suitable Firmware Version ............4-2 4.1.2 DIACom Installation ................4-3 4.1.3 DIACloud Account Registration ..............4-3 4.1.4 Bind DIACloud Account ................4-5 DIACom Operation ..................4-6 4.2.1 Setup a Secure Tunnel ................4-6 4.2.2 Create a Virtual Serial-Port ..............
  • Page 7 6.2.4 Registers View ..................6-6 6.2.5 Alarm List .................... 6-7...
  • Page 8 Chapter 1 Product Introduction Table of Contents Product Overview ..................1-3 1.1.1 Network Design ..................1-4 1.1.2 Features ....................1-4 1.1.3 Front Panel Ports and LEDs ..............1-5 1.1.4 Top Panel ..................... 1-5 1.1.5 Bottom Panel ..................1-6 1.1.6 Dimension .................... 1-7 Package Checklist ..................
  • Page 9 About This Manual The user manual is suitable for DX-2100RW-WW. If you need to use the Delta DX-2100 series products in China areas, please refer to the model name DX-2100RW-CN on the Delta website, or contact our branch offices or distributors.
  • Page 10: Product Overview

    Ch ap te r 1 Pro duc t In tr oduc tio n ประกาศเร ื ่ องระบบไร ้สายของไทย “เคร ื ่ องว ิ ท ย ุ ค มนาคมน ี ้ ม ี ร ะด ั บ การแผ ่ ค ล ื ่ นแม ่ เ หล ็ ก ไฟฟ ้ าสอดคล ้องตามมาตรฐานความปลอดภ ั ย ต ่ อ ส ุ ข ภาพของมน ุ ษ ย ์จากการใช ้เคร ื ่ องว ิ ท ย ุ ค มนาคมที ่ คณะกรรมการก...
  • Page 11: Network Design

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 1.1.1 Network Design DIACloud platform services supported, users can connect intelligent devices from different locations to the internet with DX-2100RW-WW and use point-to-point connection with the router for a safe and reliable data transmission and additionally save the costs of VPN device operation as well as maintenance.
  • Page 12: Front Panel Ports And Leds

    Ch ap te r 1 Pro duc t In tr oduc tio n  Network Flow Monitoring  Network Fault Detection and Diagnosis  DIACloud Service to Secure Point-to-point Data Transmission, to Manage Device Configurations Piece by Piece or in Batch and to Upgrade Firmware Remotely 1.1.3 Front Panel Ports and LEDs 1.1.4...
  • Page 13: Bottom Panel

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 1.1.5 Bottom Panel Notice This router’s reset button is on the front panel. By pressing the Reset button, users can reset the router or reset the router to factory default settings.
  • Page 14: Package Checklist

    Ch ap te r 1 Pro duc t In tr oduc tio n 1.1.6 Dimension Unit = mm Package Checklist Unpack the package carefully and check the package contents. The package should contain the following items:  DX-501L1-CN Industrial 4G Cloud Router x 1 ...
  • Page 15 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Memo 1 - 8...
  • Page 16: Chapter 2 User Interface

    Chapter 2 User Interface Table of Contents Web-based GUI Configuration ............... 2-2 2.1.1 System Connection ................... 2-2 2.1.2 Default IP Address/Account/Password ............2-2 2.1.3 Local Network Setups ................2-2 2.1.4 Logging in ....................2-4 DIADevice ..................... 2-5 2.2.1 Device Connection and Detection ..............2-5 2.2.2 Network Setting ..................
  • Page 17: Web-Based Gui Configuration

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Web-based GUI Configuration The DX-2100RW-WW Industrial 3G Cloud Router provides a friendly Web Browser Configuration for users to set up and operate more intruitivly. 2.1.1 System Connection Connect the DX-2100RW-WW with a computer directly or via a switch/hub.
  • Page 18 Cha p ter 2 In tr oduc tio n to Use r In ter face Click Obtain DNS server address automatically and then click OK to get a DNS server address automatically using DHCP. 2 - 3...
  • Page 19: Logging In

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Set up the IP address manually. (The IP address of the computer should be in the same subnet as the router’s.) Since the router’s default IP address is 192.168.5.5 and the subnet mask is 255.255.255.0, the computer’s IP address can be set between 192.168.5.1 to 192.168.5.254 except 192.168.5.5.
  • Page 20: Diadevice

    Cha p ter 2 In tr oduc tio n to Use r In ter face After login, you can see the main selection area on the left hand side and the upper area of the page. The detailed settings can be seen on the right side of the page. DIADevice DIADevice is a tool for quickly configuring network devices.
  • Page 21 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter After DIACom detects the device, it will automatically go to the login page, and the user needs to enter login password on the login page. 2 - 6...
  • Page 22: Network Setting

    Cha p ter 2 In tr oduc tio n to Use r In ter face After passing the authentication, the device information page is displayed, including the basic device information (Device Name, S / N, firmware, LAN IP address), network status, WAN information, and cloud service information 2.2.2 Network Setting This feature allows users to quickly configure network in two steps.
  • Page 23 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter The default is automatic. If you can not connect to the Internet using auto-setup, please use manual settings. After the device successfully connected to the Internet, the connection was successful. 2 - 8...
  • Page 24: Bind Device

    Cha p ter 2 In tr oduc tio n to Use r In ter face 2.2.3 Bind Device This feature allows users to quickly bind devices to the DIAcloud in three steps. Click “Bind Device” Enter the DIAcloud account number and password, and click Next. 2 - 9...
  • Page 25 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter After binding configuration is configured, click “Bind” to bind. If your device is successfully bound to the cloud, the following screen will appear Notice If the device has been bound to the cloud account, you need to switch to another cloud account binding, repeat 1-3 steps only and then enter the new cloud account...
  • Page 26: Open Device Webpage

    Cha p ter 2 In tr oduc tio n to Use r In ter face 2.2.4 Open Device Webpage Click open device webpage button, the browser will open the device settings page, users can set the parameters of RS232 / 485 configuration. 2 - 1 1...
  • Page 27: Typical Application Configuration

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Typical application configuration DX-2100 is an industrial-grade cloud router, providing users an easiler and faster experience of remote data collection and remote device debugging. 2.3.1 Data collection DX router can connect to the Slave via serial port or Ethernet port, router with more than 2000 built-in registers, supporting...
  • Page 28 Config DX Router Please find below the guide to configuring the DX router for the purpose of making it as the modbus master to collect the data from Delta PLC via RS-485.  Connect DX router to local PC via cable and login the config GUI. See section 2.1 for more details...
  • Page 29 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Normally the router has already been connected to internet with preset parameters of mobile network. Users can go to “Status”-“network status” in the menu to confirm the connection is ready. ...
  • Page 30 Cha p ter 2 In tr oduc tio n to Use r In ter face  Go to “Cloud Service”-“Cloud configurations” and bind the device with DIACloud account Please find below for the detailed configuration:  Click the "verify" button to verify the user name/password, the below messages will be displayed after verification passes.
  • Page 31: Remote Debugging

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter View data in DIACloud  Browsing DIACloud website, login with your account.  Click “Devices” in the menu, find the target device and click the to view the detail.
  • Page 32 If your DIACloud account already exists, skip to step 2. To register a new account, please refer to section 2.3.1 Config DX Router Please find the below steps to perform remote debug with Delta PLC via RS-485 by configuring the DX router. ...
  • Page 33 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Go to ”System”-“RS485” in the menu and set the working mode as “Transparent mode”, configuration as follows:  Go to ”Cloud Service”-“Cloud configurations” and bind the device with DIACloud account, please refert to section 2.3.1 for more details.
  • Page 34 Cha p ter 2 In tr oduc tio n to Use r In ter face  Select the tunnel group which the target DX device belongs to. Set up local IP address same segment with DX route and click “Create Tunnel” button. Messages will be shown on the lower-left corner of the status bar after the tunnel is created.
  • Page 35 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  After the virtual serial port is created, open the corresponding debugging tool WPLSoft, you can upload and download the program to the PLC remotely with the connection to DX router through RS-485. 2 - 2 0...
  • Page 36 Cha p ter 2 In tr oduc tio n to Use r In ter face 2 - 2 1...
  • Page 37: Chapter 3 Functions

    Chapter 3 Functions Table of Contents Status ......................3-3 3.1.1 Device Information ................3-3 3.1.2 Network Status ..................3-5 3.1.3 Routing Table ..................3-6 3.1.4 Local Log ....................3-6 3.1.5 Traffic Statistics ..................3-7 3.1.6 Cloud Status ..................3-7 3.1.7 Connected Device ..................
  • Page 38 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.4.13 Import Job List..................3-55 3.4.14 Network Diagnosis ................3-55 3.4.15 Trouble shooting ................. 3-56 3.4.16 System Reboot ................... 3-57 3.4.17 Privilege Management ................3-57 3.4.18 Event Management ................
  • Page 39: Status

    CH3 Func ti ons Status You can view summary or detailed information of Device Information, Network Status, Routing Table, Local Log, Traffic Statistics, Cloud Status, and Connected Device. 3.1.1 Device Information This page shows basic information on the Hardware/Software version and Resource Usage Information. 3 - 3...
  • Page 40 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Hardware Version Item Description Release to manufacturing version of the router RTM Version Hardware release date Release Date Serial number of the router ...
  • Page 41: Network Status

    Cha p ter 3 In tr od ucti on to F unc tio ns 3.1.2 Network Status This page shows basic information on Cellular Network Status and LAN Status. Cellular Network Status includes the Operator, Signal Strength, Connection Status, Online Duration, Authorization Mode, APN, Telephone Number, IP Address Network Mask, Gateway Address, primary DNS, and Secondary DNS.
  • Page 42: Routing Table

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.1.3 Routing Table This page shows basic information on the routing table, including the Destination, Gateway, Network Mask, HOPS and Network Interface. 3.1.4 Local Log This page shows logs of the router, including the System log, Warning lot and the Debug log.
  • Page 43: Traffic Statistics

    Cha p ter 3 In tr od ucti on to F unc tio ns 3.1.5 Traffic Statistics This page shows network traffic information of the router, including the data sent and received over Cellular and LAN. You can use the buttons on the right side to refresh or clear the traffic information. 3.1.6 Cloud Status This page shows cloud server information of the router, including the Registration Status, Service Status, and Activated...
  • Page 44: Connected Device

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.1.7 Connected Device This page shows information of the devices connected to the router, including the IP Address, Host Name, MAC Address. Network You can set up networks, including the WAN Configurations, LAN Configurations, Static Routing Rules and Dynamic DNS.
  • Page 45 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Operator Select Auto or Others for the Operator from the dropdown list.  Auto: the system will detect the operator from the inserted SIM card AUTO and set up accordingly.
  • Page 46 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default User Name This name is provided by the operator. When “Auto” is selected, the system will set the name up automatically and users cannot change the setting. Password This password is provided by the operator.
  • Page 47: Pin Management

    Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Maximum Transmission Unit is the largest packet that can be transmitted 1492 over packet based networks. Auto Detect With two ways to detect the network connection automatically, users can choose between “PING”...
  • Page 48 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  A pop-up dialogue box would be displayed as below if the verification fails.  If the verification passes, it will display as below. Description Default SIM card status...
  • Page 49 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default A personal identification number used in SIM card is a security measure to protect SIM card from being stolen. Remember my PIN Enable this function to remember the PIN code in the system and the code Uncheck would be input automatically every time after booting.
  • Page 50: Lan Configurations

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.2.3 LAN Configurations This page is used for setting up the LAN, including the Device Name, IP Address, Network Mask, and DHCP Server. Description Default Device Name...
  • Page 51 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Options here are 1 to 3 days. First IP Address To increase the number of addresses available to clients, you can change 192.168.1.100 the Start Address. Last IP Address To increase the number of addresses available to clients, you can change 192.168.1.200...
  • Page 52: Static Routing Rules

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Figure 3.2.4 Static Routing Rules This page is used for setting up the Static Routing, including the Rule Name, Network Interface, Enabled, Destination IP, Network Mask, Gateway Address and Metric.
  • Page 53 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Rule Name Set up a name for your rule. The name shall be composed of letters, numbers and underline, starting with a letter or number. The maximum string length is 32 bytes.
  • Page 54: Dynamic Dns

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.2.5 Dynamic DNS This page is used for setting up the Dynamic DNS Settings, including the Dynamic DNS, Service Provider, Domain User Name, Password, and the Refreshing Interval. Description Default Dynamic DNS...
  • Page 55: Firewall

    Cha p ter 3 In tr od ucti on to F unc tio ns Firewall You can set up firewall configurations, including the Firewall Settings, DMZ Settings, Port Forward, Port Trigger, URL Filter, MAC Filter, and IP Filter. 3.3.1 Firewall Settings This page is used for setting up the basic firewall settings, including the SPI firewall switch, WAN Ping response, LAN SSH function and WAN SSH.
  • Page 56: Port Forward

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default DMZ Server Demilitarized zone (DMZ) is a special segment of the local network reserved for servers accessible from the Internet, adding an additional layer of Disable security.
  • Page 57 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Network Services Select the common network services. Refer to the following common service Customized list for optional values. Service Name Set up the service name for port forwarding. The name is composed of letters, numbers and underline, starting with a letter or number.
  • Page 58: Port Trigger

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Protocol Starting Port Ending Port Service name HTTP 23566 23566 ICUII 6670 6670 IP_PHONE 1720 1720 NetMeeting News TCP/UDP 1723 1723 PPTP Telnet TCP/UDP 27960 27960...
  • Page 59 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Service Name Set the service name for port triggering. The name is composed of letters, numbers and underline, starting with a letter or number. The maximum string length is 32 bytes.
  • Page 60: Url Filter

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.3.5 URL Filter This page is used for setting up the URL Filter, including configuring the URL Address, LAN IP Address and Status. URL Filter is used to block particular website from the local network.
  • Page 61: Ip Filter

    Cha p ter 3 In tr od ucti on to F unc tio ns After clicking the “Add A MAC Address”, you will see the following page. Description Default MAC Address Manually input the MAC address that you’d like to block. Device Name Enter the device name corresponding to the set MAC address.
  • Page 62: System

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Source IP Set the source IP. Any Address Source Port Set the source port where the datagram came from. Any port Destination IP Set the destination IP.
  • Page 63: Time Zone Configurations

    Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Old Password Input the original password. admin New Password Input the new password you’d like to use. The password length should be 5-12 digits and is composed of lowercase letters, uppercase letters (case sensitive), numerals 0-9 and underline.
  • Page 64: Rs232

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default The current time of device Here shows the current time of your device. Set Local PC Time Configure time and date settings of the router to be synchronized with the connected PC.
  • Page 65 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Flow Control Set the flow control. Options are None, XON, XOFF, RTS, and CTS. None  Transparent mode When RS-232 is under transparent mode, users can debug devices and upload/ download data remotely by creating virtual serial ports via DIACom.
  • Page 66 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Slave ID Enter the MODBUS ID. The value is between 1 and 247. Mode Set the communication mode for the device. Device support Modbus RTU and Modbus RTU Modbus ASCII Timeout...
  • Page 67 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Slave ID Set the MODBUS ID for DX router. Invalid in Master mode. Mode Set the communication mode for the device. Device support Modbus RTU and Modbus RTU Modbus ASCII.
  • Page 68 Slave Starting Address (decimal) Set the slave starting address for read/write the registers in a PLC.  Delta PLC: Enter the internal D register number. If you need to read / write D0, please enter 0 here.  Other: Enter the Hexadecimal or Decimal actual address. For example: Holding Register: 400100, take 0100 (decimal) that is 64 (hex).
  • Page 69 Cha p ter 3 In tr od ucti on to F unc tio ns  Serial Server-TCP Server In this working mode, DX series routers working as TCP servers receive data packets from clients, then send to RS-232 after parsing. Description Default TCP Alive Check Time...
  • Page 70 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Serial Server-TCP Client Under this mode, DX routers will be clients of device servers to send data with a TCP connection. Description Default TCP Alive Check Time Configure the duration of the idle state before disconnect TCP automatically.
  • Page 71 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Designated local port Set local ports for your device. 14001~14004 Packing Length Configure the length of the accumulated data for packets sending, ranging 0~1024 bytes. Set as 0 for real-time data transmission. Force Transmit Configure the length of time awaiting to transmit a data packet forcibly, ranging 0~65535ms.
  • Page 72 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Destination IP address and Port Set the destination IP addresses and ports. (Default:6001~6004, configurable) IP addresses and ports cannot be duplicated with a maximum of 4 servers allowed Default port to be connected at the same time.
  • Page 73 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Slave ID Set the MODBUS ID for DX router. Invalid in MC Master mode. Mode It’s fixed to “MC ASCII” in MC master mode. MC ASCII Timeout Set the timeout timer from 200ms to 5000ms.
  • Page 74: Rs485

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Controller MITSUBISHI It’s fixed to “MITSUBISHI PLC” in MC master mode. Address Type Address types would be D/M/S/X/Y, which D is a word type and M/S/X/Y are bit types.
  • Page 75 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Set the parity bits for the serial port. Options are None, Odd and Even. None  Transparent mode When RS-485 is under transparent mode, users can debug devices and upload/ download data remotely by creating virtual serial ports via DIACom.
  • Page 76 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Slave ID Set the MODBUS ID. The value is between 1 and 247. Mode Set the communication mode for the device. Device support Modbus RTU and Modbus RTU Modbus ASCII Timeout...
  • Page 77 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Slave ID Set the MODBUS ID for DX router. Invalid in Master mode. Mode Set the communication mode for the device. Device support Modbus RTU and Modbus RTU Modbus ASCII.
  • Page 78 Slave Starting Address (decimal) Set the slave starting address for read/write the registers in a PLC.  Delta PLC: Enter the internal D register number. If you need to read / write D0, please enter 0 here.  Other: Enter the Hexadecimal or Decimal actual address. For example: Holding Register: 400100, take 0100 (decimal) that is 64 (hex).
  • Page 79 Cha p ter 3 In tr od ucti on to F unc tio ns  Serial Server-TCP Server In this working mode, DX series routers working as TCP servers receive data packets from clients, then send to RS-485 after parsing. Description Default TCP Alive Check Time...
  • Page 80 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter  Serial Server-TCP Client Under this mode, DX routers will be clients of device servers to send data with a TCP connection. Description Default TCP Alive Check Time Configure the duration of the idle state before disconnect TCP automatically.
  • Page 81 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Designated local port Set local ports for your device. 14001~14004 Packing Length Set the length of the accumulated data for packets sending, ranging 0~1024 bytes.
  • Page 82: Modbus Tcp

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Destination IP address and Port Set the destination IP addresses and ports. (Default:6001~6004, configurable) IP addresses and ports cannot be duplicated with a maximum of 4 servers allowed 6001~6004 to be connected at the same time.
  • Page 83 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Working Mode  Modbus TCP Server: Only Modbus TCP server works. And supports up to 32 Client to connect. Modbus TCP  Modbus TCP Server+Client: Modbus TCP server + Modbus TCP client work Server at the same time.
  • Page 84 247. Controller In master mode, device types options are:  Delta PLC: Use this option for Delta DVP / AH / AS series PLCs Delta DVP  Other: Use this option for non-Delta PLCs. HEX means hexadecimal address; DEC means decimal address.
  • Page 85: Siemens Tcp

    Slave Starting Address (decimal) Set up the slave starting address for read/write the registers in a PLC.  Delta PLC: Enter the internal D register number. If you need to read / write D0, please enter 0 here.  Other: Enter the Hexadecimal or Decimal actual address. For example: Holding Register: 400100, take 0100 (decimal) that is 64 (hex).
  • Page 86 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Defualt Description Add Server Choose the target Siemens TCP server for connection to the routers with 32 servers supported at most. Controller S7-300 Set the model type of the Siemens devices for communication.
  • Page 87 Cha p ter 3 In tr od ucti on to F unc tio ns Defualt Description Export Configure List Export all the mapping and save as a file in the local PC. Import Configure List Import mappings from the local PC. Click “浏览” to select the target file first. Read/ Write Set the access permissions for the mapped register address: ...
  • Page 88: Log Settings

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Defualt Description Edit To edit the parameters or change the setting by clicking on the target field. 3.4.7 Log Settings This page is used for configuring the log settings, including Log to Console, Remote Log Service, Remote Log Server Address, and Port of Remote Log Server.
  • Page 89: Firmware Upgrade

    Cha p ter 3 In tr od ucti on to F unc tio ns 3.4.8 Firmware Upgrade This page is used for upgrading the system. Description Default Select Firmware Click “Browse” to select the new firmware file. Upgrade Click “Upgrade” to upgrade firmware. The device will reboot after the upgrade is done.
  • Page 90: 3.4.10 Scheduled Jobs

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Click “Restore To Factory Default” to reset the configurations to the factory defaults. The device will reboot after the reset is done. 3.4.10 Scheduled Jobs This page is used for scheduling job configurations, including ADD A New Job, Export Job List, and Import Job List.
  • Page 91: 3.4.12 Export Job List

    Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Date Select a specific date to perform the scheduled job. 2015.01.01 Job Type Select one of the job type for the scheduled job.  Restart device Restart device ...
  • Page 92: 3.4.15 Trouble Shooting

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Diagnosing Method Selections are “Ping Test”, “Route Trace” and “Cloud Service Ping Test Diagnose”. Host Name/IP Address Select the domain name or IP address of the server that you want to test.
  • Page 93: 3.4.16 System Reboot

    Cha p ter 3 In tr od ucti on to F unc tio ns 3.4.16 System Reboot This page is used for manually rebooting the system. Click “Restart Device” and the system will reboot. 3.4.17 Privilege Management Privilege management use in order to set the white list of phone numbers and the device operation can be triggered via the specific SMS text from the white list of phone numbers.
  • Page 94 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Currently, there are three the main SMS settings: 1. Short Message Control Gateway. 2. Short Message Controlling PLC. 3. Control List of Event Management. Setting interface as follows: 3 - 5 8...
  • Page 95 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Short Message Center Number Input the short message center number supported by this SIM card, the input format is: "+" "country code" "short message center number". Example: +8613800100500 Send Short Message Test Confirm SMS module related functions are executed correctly, you can send a...
  • Page 96: 3.4.18 Event Management

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 3.4.18 Event Management This page is used for setting up 3 types of events, Communication Verification, Alarm Event and SMS Queries Event.  Communication Verification: When this option is selected, the router will monitor and check if this channel is trustable to ensure a safe communication between a router and a PLC via MODBUS TCP, MODBUS ASCII or MODBUS RTU.
  • Page 97 Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Alarm Name Input an alarm name. The name shall be composed of numbers, English letters, uppercase and lowercase. The maximum string length is 32 bytes. Alarm Description The alarm description shall be composed of numbers, English letters, uppercase and lowercase.
  • Page 98 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default  Description: the description of the occurred alarm For example: Register $2048 represents electrical voltage, the value of register $2048 is 10, and the alarm content is set as: {Date} {Time} Voltage = {$2048}, then the alarm content received by users will be: 2016/06/01 10:00:00(currently time) Voltage = 10.
  • Page 99: 3.4.19 Register Management

    Cha p ter 3 In tr od ucti on to F unc tio ns Description Default be self-defined.  Time: the time when the alarm occurred  Date: the date when the alarm occurred  Name: the name of the occurred alarm ...
  • Page 100 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Click ADD to upload register addresses to the cloud. Up to 20 addresses can be added. Export Configure List Export all the existing rules and save as a file named “fixed_register_list.cfg” in the local PC Import Configure List Import configure list from the local PC.
  • Page 101: Cloud Service

    Cha p ter 3 In tr od ucti on to F unc tio ns Cloud Service 3.5.1 Cloud Configuration In this page, user can assign the cloud account which will be used to connect to DIACloud by device. Input the user name, the password and click “Verify”.
  • Page 102 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter the cloud HDCP server or a user specified). 5. Your browser will access to the DX router with new IP address automatically if DIACloud account binds with DIACloud server successfully.
  • Page 103 Cha p ter 3 In tr od ucti on to F unc tio ns 7. In this situation, the browser will access with 192.168.1.1 and the service status will be “Disable”. You can re-enable the service status to rebuild the secure tunnel again in cloud configurations. 8.
  • Page 104: Secure Tunnel Firewall

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default  TCP: When the network packet loss is serious, it is recommended to select TCP. After binding the cloud account, you can still change this option, but you must disable the cloud service before changing.
  • Page 105: Cloud Log

    Cha p ter 3 In tr od ucti on to F unc tio ns Description Default Allow multicast in secure tunnel Set the security tunnel, whether to allow multicast transmission of the nature of the packet. Options: Allowed, not allowed Firewall of secure tunnel Set up the specified MAC device will be allow or forbid to transmit the data in the secure tunnel.
  • Page 106: Sd Card Quick Configuration

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Description Default Select Log Level Specify to download the cloud service module log. Options as below:  Uploader: Data upload module Uploader  Secure Tunnel: Secure Tunnel module ...
  • Page 107 Cha p ter 3 In tr od ucti on to F unc tio ns The following beep codes are for SD Card Quick Configurations, its definition that the various combinations of the configuration file exist on SD card. (× – fail, √ - success or not this operation) Beep Code Upgrade.bin backup.cfg...
  • Page 108 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter MEMO 3 - 7 2...
  • Page 109: Chapter 4 Diacom

    Chapter 4 DIACom Table of Contents Introduction to DIACom ................4-2 4.1.1 Select a Suitable Firmware Version ............4-2 4.1.2 DIACom Installation ................4-3 4.1.3 DIACloud Account Registration ..............4-3 4.1.4 Bind DIACloud Account ................4-5 DIACom Operation ..................4-6 4.2.1 Setup a Secure Tunnel ................
  • Page 110: Introduction To Diacom

     If you need to configure or monitor your controller, you will need to install programmable logic controller software, for example WPLSoft/ISPSoft for Delta PLC. 4.1.1 Select a Suitable Firmware Version Find a suitable DIACom firmware version according to the following table below for your router.
  • Page 111: Diacom Installation

    Cha p ter 4 In tr od ucti on to D IACo m 4.1.2 DIACom Installation Obtain the DIACom firmware package from the official website or from our sales representative. Administrator privileges are required to run and install the package. Uninstall older versions of DIACom before downloading new DIACom firmware package.
  • Page 112 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter After clicking “CREATE AN ACCOUNT”, a congratulation page will be prompted and an activation email will be sent to the email address you have used as your DIACloud account. You will find an activation email sent from no-reply@diacloudsolutions.com in your email box.
  • Page 113: Bind Diacloud Account

    Take note of the assigned IP address, it will be used when logging to the DIACloud.  When selecting “No”: The IP address can be manually set. The IP address of the DX-2100 Series and the WAN of your connected PC should be in different network segments. 4 - 5...
  • Page 114: Diacom Operation

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter DIACom Operation 4.2.1 Setup a Secure Tunnel Make sure there is internet connectivity, before creating a secure tunnel between your local PC and router via the DIACom. Http Proxy and Port Agent are configurable in DIACom network setting function, you can set it to avoid the possible limitation.
  • Page 115 Cha p ter 4 In tr od ucti on to D IACo m Notice  DIACom will automatically determine whether the port agent needs to enable.  Make sure that the external network port 80 and port 443 are opened and can access any network domains and IP addresses After the login is successful, the software displays the security tunnel page.
  • Page 116 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Notice If it is found that the static IP address is configured from DIACom, the IP address of the local IP address in the bottom right corner will be different from the original setting. Please change according to the following settings.
  • Page 117 Cha p ter 4 In tr od ucti on to D IACo m Click the Networking tab. Under This connection uses the following items, click either Internet Protocol Version 4 (TCP/IPv4) Set the IP address of the local computer manually. However, you’ll need to make sure there are no IP conflicts.
  • Page 118: Create A Virtual Serial-Port

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter After successful connection with the cloud, the local computer will be able to use debugging tools or monitoring software to debug, monitor, and program the remote network interface devices.
  • Page 119 Cha p ter 4 In tr od ucti on to D IACo m Click on the “Create” button to create a virtual COM port on the local PC, related to the RS-232 or RS-485 port on the remote devices. If the RS-232 or RS-485 port is not working with transparent mode, the corresponding “Create”...
  • Page 120: Remote Control And Monitoring Via Diacom

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Notice  If the device's RS-232 / RS-485 is not operating in Transparent mode, the corresponding button is grayed out.  DIACom will prompt an error message if the FW version of DX is under V1.3.3. 4.2.3 Remote Control and Monitoring via DIACom 4.2.3.1...
  • Page 121 Cha p ter 4 In tr od ucti on to D IACo m Notice If the PLC is Siemens S7-200, you can select the “PPI” in the DIACom to support PPI protocol. Open the WPLSoft to check if the COM parameters are consistent with the settings on your router.
  • Page 122: Automation Startup

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 4.2.4 Automation Startup Users can set Automation Startup for DIACOM, The setting steps see blow. Login to DIACom. Click on the icon button in the upper right corner of the windows, and select "Settings".
  • Page 123: Chapter 5 Diacloud

    Chapter 5 DIACloud Table of Contents Introduction to DIACloud ................5-2 5.1.1 Select a Suitable Firmware Version .............. 5-2 Instructions for DIACloud ................5-2 5.2.1 Register and Login ..................5-2 5.2.2 Home ...................... 5-4 5.2.3 Devices ....................5-6 5.2.4 Alarm ....................5-16 5.2.5 Secure Tunnels ..................
  • Page 124: Introduction To Diacloud

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Introduction to DIACloud DIACloud Web is a web portal of DIACloud cloud platform. Users can check the status of connected industrial device through DIACloud Web, browse data that has been collected, receive warnings, notices and other messages that are sent by cloud platform, create and manage sub-account and virtual safety network and check login and interface logging, to improve the manageability of devices, optimize the device performance and efficiency, save the operation cost and enhance the service quality.
  • Page 125 CH5 In trod uc ti on to IOT D IACl ou d After clicking “CREATE AN ACCOUNT”, a congratulation page will be prompted and an activation email will be sent to the email address you have used as your DIACloud account. You will find an activation email sent from no-reply@DIACloudSolutions.com in your email box.
  • Page 126: Home

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Open the DIACloud web page (http://www.DIACloudSolutions.com). Log in using your account that you have registered. 5.2.2 Home The Home Page will show up after login. 5 - 4...
  • Page 127 CH5 In trod uc ti on to IOT D IACl ou d Item Description Menu User can switch to corresponding function through menu on the left. Devices Total The number of total devices. Devices is Online The number of total online devices. Alarms in 24 Hours The number of alarms in Recently 24 hours.
  • Page 128: Devices

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Click , we accept PayPal payments and process credit cards on your order forms. 5.2.3 Devices It will switch to page of device list after clicking “Devices” in navigation bar. 5 - 6...
  • Page 129 CH5 In trod uc ti on to IOT D IACl ou d Item Description You can filter the device base on you input the key word of the device name. Filter base on tunnel group, show all devices or only show the devices under user specified tunnel group.
  • Page 130 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter OVERVIEW: The page will show the basic information of the device and the latest alarm message. Item Description It represents that device is online if background color is blue, and device is offline if shows gray.
  • Page 131 CH5 In trod uc ti on to IOT D IACl ou d  Modbus TCP: work modes of Modbus TCP, including Modbus TCP Server, Modbus TCP Client and Closed  RSSI: it means signal strength of device which contains 5 bars; the larger the number of green bars is, the stronger the signal strength is;...
  • Page 132 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Register Table Show the register table, displaying a maximum of 10 registers per page. Show the register name, when you do not configure an alias in the register, the Register Name register number is displayed.
  • Page 133 CH5 In trod uc ti on to IOT D IACl ou d Item Description Set the Start Date and query the historical data for a specific time. Date Start Set the End Date and query the historical data for a specific time. Date End Register Value History Diagram The latest trend chart of value of register;...
  • Page 134 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Item Description Length can be set to Word, DWord and Float.  DWord: DWord needs to use two DX internal registers. For example: $2050 and $2051 are set to DWord and combined as one.
  • Page 135 CH5 In trod uc ti on to IOT D IACl ou d  Example 2: If you want to convert the register value to the text such as the register value of 1 showing the text as ‘NO’; register value of 2 showing the text as ‘OFF’ Input the code in function (val) {…} as the following picture and Click “Save”...
  • Page 136 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Item Description  Device Data Usage: Show device traffic usage till now and total capacity.  Account Traffic Usage: Account traffic is the total amount of traffic showing additional purchases.
  • Page 137 CH5 In trod uc ti on to IOT D IACl ou d  After Click the in Storage field, it will show the storage package select page. User can add a package to cart or checkout directly. MORE: This page will show the Serial Number, Software Version, Hardware Version, and IMEI for users. 5 - 1 5...
  • Page 138: Alarm

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Item Description Serial Number Serial number of device Software Version Version information of software Hardware Version Version information of hardware IMSI International Mobile Subscriber Identification Number. Delete binding relationship between devices and the account.
  • Page 139 CH5 In trod uc ti on to IOT D IACl ou d Users can manager the tunnel network in this page. Interface is shown as follows: Description Search the existed tunnel network. List all tunnel network under this account. Tunnel network List Add a new tunnel network.
  • Page 140: Sub Users

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Item Description The detail information of tunnel network:  Network Name: User can enter a name of tunnel network.  DHCP Option: Automatic IP Address Assignment by DIACloud. Tunnel Network Information ...
  • Page 141 CH5 In trod uc ti on to IOT D IACl ou d Item Description Search the sub users. Sub Users List Show the list of all sub users in main account. Add a sub user. Refresh the list of sub users. Modify the access control of the tunnel network.
  • Page 142 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Item Description  Edit register: Allow the Sub User to modify register  Login to DIACom: Allow the sub user to access the DIACom if the Sub Users Information option is enabled.
  • Page 143: Logs

    CH5 In trod uc ti on to IOT D IACl ou d When user login to DIACloud with main account and the sub user that we created has been activated. 5.2.7 Logs This page will show the web operation information of some users. It includes: login IP, setup of register, API interface call of DIACloud and other information.
  • Page 144: Orders

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 5.2.8 Orders In this page, users can check all orders. Continue to pay for the unpaid orders or cancel the unpaid orders. Item Description View the order detail information Pay for the unpaid order...
  • Page 145: Profile

    CH5 In trod uc ti on to IOT D IACl ou d 5.2.9 Profile In this page, QR Code of user, Package info, password management and other information will be shown. Item Description QR Code You can get the part information of user by using DIACloud APP and scanning QR Code. Account The current account information.
  • Page 146 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter MEMO 5 - 2 4...
  • Page 147: Chapter 6 Diacloud App

    Chapter 6 DIACloud APP Table of Contents Introduction to DIACloud APP ..............6-2 6.1.1 Select a Suitable Firmware Version ............6-2 6.1.2 DIACloud APP Installation ............... 6-2 DIACloud APP Function ................6-2 6.2.1 DIACloud APP Login ................6-2 6.2.2 Device List .................... 6-4 6.2.3 Device Details ..................
  • Page 148: Introduction To Diacloud App

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter Introduction to DIACloud APP DIACloud APP is the client software of DIACloud cloud platform running on mobile devices. The APP supports both iOS and Android mobile system, it enables users to view the collected field data, the locations of the field devices, and the alarms/notifications pushed by the industrial IOT cloud platform, so that keep users posted anytime and anywhere, and therefore improve the manageability of devices, optimize the device performance and efficiency, save the operation cost...
  • Page 149 Ch ap ter 6 In trod uc ti on to D IAC lou d APP Item Description Scan QR code, the QR code is generated by DIACloud Web portal, which carries the user name and password information. By scanning the QR code, user won’t need to input user name. By default, the APP will connect the default DIACloud server in the cloud, if the APP is to connect other servers, QR code should be scanned to provision the APP.
  • Page 150: Device List

    D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 6.2.2 Device List Device list will be shown after logging in the APP. Device tab and alarm tab will be shown in the APP. In the device tab, the device information will be shown, including the value of registers of the remote device.
  • Page 151: Device Details

    Ch ap ter 6 In trod uc ti on to D IAC lou d APP 6.2.3 Device Details Device details will be shown by selecting a device in the device list. Item Description Type Type of the device Time The time when the device is online. IP Address of the device Account The DIACloud account which activates the device.
  • Page 152 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter 6.2.4 Registers View Click [Register] on the device details page to switch to the register page In the register page, the user can browse the collected data. The register data can be refreshed by the pull-down screen.
  • Page 153 Ch ap ter 6 In trod uc ti on to D IAC lou d APP Click “ok” button, the register value will be pushed to the device. 6.2.5 Alarm List Alarm criteria can be set on the device configuration web page. When the alarm criteria are met, the device will send out alarm messages.
  • Page 154 D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter MEMO 6 - 8...

Table of Contents