Advertisement

Quick Links

D120 Installation Manual
Phase 7 / Non-Coin / Dual Timer / S.A.F.E. System
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de
bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute
blessure ou la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
JLA Limited
Meadowcroft Lane, Halifax Road
Ripponden
West Yorkshire, England
HX6 4AJ
Telephone: 01422 822282 / Fax: 01422 824390
Part No. 113375 - 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D120 and is the answer not in the manual?

Questions and answers

Summary of Contents for JLA D120

  • Page 1 D120 Installation Manual Phase 7 / Non-Coin / Dual Timer / S.A.F.E. System AVERTISSEMENT: Assurez-vous de WARNING: For your safety the bien suivre les instructions données dans information in this manual must be cette notice pour réduire au minimum le followed to minimize the risk of fire or risque d’incendie ou d’explosion ou pour...
  • Page 2 Replacement parts can be obtained from your distributor or JLA. When ordering replacement parts from JLA, you can FAX your order to JLA at 01422 824390 or telephone your order directly to the JLA Parts Department at 01422 822282. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.
  • Page 3: Table Of Contents

    Table of Contents ____________________ IMPORTANT Safety Precautions ........4 You must disconnect and lockout the electric supply and the gas supply or the steam supply Mechanical Specifications ......6 before any covers or guards are removed from the machine to allow access for cleaning, Installation Procedures ......
  • Page 4: Safety Precautions

    Dryer(s) must be exhausted to the outdoors. Although JLA produces a very versatile dryer, there are some Read and follow all caution and direction labels attached to articles that, due to fabric composition or cleaning method, the dryer.
  • Page 5 IMPORTANT: This appliance must only be installed and operated in the country of destination indicated on the dryer’s data plate. If the appliance is to be installed and operated in a country other than the one indicated on the data plate, a data plate amendment must be obtained from JLA Limited. IEC335 applies.
  • Page 6: Mechanical Specifications

    IMPORTANT: Dryer requires a clean, dry and regulated 80 PSI +/- 10 PSI (5.51 bar +/- 0.68 bar) air supply. NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. JLA Limited 113375 - 16...
  • Page 7 Mechanical Specifications _______________________________________________________ NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 113375 - 16 Telephone 01422 822282...
  • Page 8: Installation Procedures

    Every 6 months, inspect the exhaust ducting and remove any lint buildup. IMPORTANT: The dryer must be installed in a location/ environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C). JLA Limited 113375 - 16...
  • Page 9: Dryer Enclosure Requirements

    Dryer Enclosure Requirements ______ Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. As a general Even though a 12-inch (30.48 cm) clearance is acceptable, rule, an unrestricted air entrance from the outdoors it is recommended that the rear of the dryer be positioned (atmosphere) of a minimum of 1.4 feet (0.13 meters...
  • Page 10: Exhaust Requirements

    0 and must not exceed 0.3 in WC (0.74 mb). the exhaust ductwork is not critical so long as the minimum cross section area is provided. JLA Limited 113375 - 16...
  • Page 11 IMPORTANT: The minimum duct size is 16-inches (40.64 IMPORTANT: For extended ductwork runs, the cross cm) for a round duct and 14-1/4” x 14-1/4” (36.2 cm x 36.2 section area of the ductwork can only be increased to an cm) for a square duct. The duct size must not be reduced extent.
  • Page 12: Electrical Information

    NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this duct. JLA Limited 113375 - 16...
  • Page 13: Gas Information

    Electric Models Only The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, and L3), ground, and in All electrically heated dryers must be connected to the the case of 4 wire service, the neutral. These electrical electric service shown on the dryer’s data label.
  • Page 14 14.92 - 29.9 mb 10.5 in WC 11.0 in WC Liquid Propane 26.1 mb 27.4 mb Shaded areas are stated in metric equivalents * Measured at the gas valve pressure tap when the gas valve is on. JLA Limited 113375 - 16...
  • Page 15: Steam Information

    Steam Information ___________________ Consistent gas pressure is essential at all gas connections. It is recommended that a 1-inch (2.54 cm) pipe gas loop be It is your responsibility to have all plumbing connections installed in the supply line servicing a bank of dryers. An in- made by a qualified professional to assure that the gas line pressure regulator must be installed in the gas supply plumbing installation is adequate and conforms to local and...
  • Page 16 External regulation/filtration of 80 psi (5.51 bar) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved. JLA Limited 113375 - 16...
  • Page 17: Preparation For Operation / Start-Up

    Preparation for Operation / Start-Up Steam Damper System Operation The steam damper, as shown in the illustration below The following items should be checked before attempting (Diagram 1), allows the coil to stay constantly charged to operate the dryer: eliminating repeated expansion and contraction. When the •...
  • Page 18: Compressed Air Requirements

    External regulation/filtration of 80 psi (5.51 bar) must be provided. It is suggested that a filter/regulator/gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved. JLA Limited 113375 - 16...
  • Page 19: Shutdown Instructions

    NOTE: When ordering replacement parts from the distributor or IMPORTANT: The dryer produces combustible lint JLA be sure to give them the correct model number and serial and must be exhausted to the outdoors. Every 6 number so that your parts order can be processed in an months, inspect the exhaust ducting and remove any expeditious manner.
  • Page 20: Adjustments

    Check all V-belts for tightness and wear. Retighten, realign, burner box, looking at the burner from the back of the dryer. or replace V-belt if required. WARNING NOTE: Replace in matched sets (both belts). Discontinue power to dryer before attempting to reset hi-limit. JLA Limited 113375 - 16...
  • Page 21: Data Label Information

    No L.E.D. indicator indicates a power or an internal failure has occurred. For Models with HSI Module When contacting JLA, certain information is required to ensure proper service/parts information from JLA. This information is on the data label that is affixed to the rear upper left back area of the dryer, which can be viewed either through the openings in the dryer’s back panel/guard, or by...
  • Page 22: Water Information

    Flexible 1/2 feeds must be provided to avoid damage to Forward direction output. If the request to tumble the drum electric water solenoid valve by vibration. in the Forward direction is made, then the L.E.D. is ON. JLA Limited 113375 - 16...
  • Page 23 IMPORTANT: Flexible supply line/coupling must be used. The water connection for the manual bypass is made Solenoid valve failure due to hard plumbing connections will to the “T” or “three way” fitting, which has a 3/8” F.P.T. void warranty. and a coupling must be used to provide the minimum 1/2”...
  • Page 24 Part No. 113375 16 - 12/01/15...

Table of Contents