ADC D30 DRYER
Installation Specification - Dimensions shown in millimetres
A - Electrical connection, B - Gas Inlet, C - Steam Inlet, D - Steam return, E - Exhaust outlet, F - Steam dryer operating height,
G - Water Inlet (S.A.F.E. Sensor Activated Fire Extinguishing system), H - Compressed air connection (Steam only)
Model
Dimensions (HxWxD) Gas/Steam
Electric
Boxed
Nett weight
Gas/Electric
Steam
Water Connection
No of inlet valves
Minimum pressure
Inlet size
Flow rate
Electrical
Standard Gas or Steam
Reversing motor model
Electric
Motor rating
Gas
Heat input
Supply Pressure
Natural gas
Burner Pressure
Natural gas
Supply Pressure
LPG
Inlet size
Exhaust & Ventilation - Recommended Guides
Exhaust outlet size
Total max. length
Horizontal
Vertical
Max permissible exhaust back pressure
Airflow
Gas/Electric/Steam
Free air intake requirement
Steam
Consumption
Operating Pressure
Connection - supply/return
Compressed air (Steam model ONLY)
Consumption
Pressure
Connection
Minimum installation distance - Rear
D30
1835 x 870 x 765mm
1910 x 870 x 765mm
1960 x 910 x 780mm
185kg (407lb)
197kg (433lb)
1 cold
1.4 bar (20 psi) (max 60psi)
3
/
" BSP via 15mm supply
4
20 litres/min
240v/50Hz/1ph/13A
415v/50Hz/3ph+N/10A/ph (optional)
415v/50Hz/3ph+N/32A/ph - 18kw
373 watt
23kw (78,000Btu)
15mb(6"wc) min - 30mb (12"wc) max - above 30mb a regulator must be fitted.
8.7mb(3.5"wc)
Propane 37mb(14.8"wc) Butane 28mb(11.2"wc)
1
1
/
" BSP male via a
/
" flexible armoured hose
2
2
200mm (8") dia
25.9m (85ft) This allows for the use of 1 No 90 degree bend
16.7m (55ft) This allows for the use of 1 No 90 and 1 No 180 bend
0.74mb (0.3"wc)
10.93m
3
(386ft
3
)/min
0.05m
2
(78in
2
)
45kg/hr (100lb/hr) @ 125 psi
7kg/cm
3
(100psi) - 8.8kg/cm
3
(125psi)
1
1" BSP/
/
" BSP
2
0.02m
3
/hr (0.75ft
3
/hr)
80psi
1
/
" BSP
8
400mm
I/D30/09/04