Download Print this page
Sealey SA661 Manual

Sealey SA661 Manual

Composite air needle scaler

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instructions
protection
1. SAFETY
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
WARNING! Disconnect from air supply before changing accessories or servicing.
Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be
9
dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure that all connections are secure.
9
Only use needles which are specifically designed for use with a needle scaler.
9
Wear approved safety eye/face shield, ear defenders, and hand protection.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and non essential persons away from the working area.
9
DO NOT use the needle scaler for a task it is not designed to perform.
8
WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).
DO NOT use needle scaler unless you have been instructed in its use by a qualified person.
8
DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply.
8
DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting.
8
DO NOT direct air from the air hose at yourself or others.
8
When not in use disconnect from air supply and store in a safe, dry, childproof location.
9
2. INTRODUCTION
Suitable for cleaning heavy paint and rust scale from metal surfaces. Composite housing protects user from chill and helps to reduce
vibration. Palm control trigger mechanism. Directional, low noise air exhaust can be rotated 360°, giving operator added protection.
Replacement needle set available.
3. SPECIFICATION
Model No .................................................................... SA661
Air Consumption:............................................................ 6cfm
Free Speed: ............................................................ 4600bpm
Inlet Size: .................................................................1/4"BSP
Nett Weight: ................................................................. 1.3kg
Noise Power/Pressure: ...................................... 92/90dB(A)
Operating Pressure: ...................................................... 90psi
Stroke .......................................................................... 38mm
Vibration/Uncertainty: ........................................ 4.9/2.45m/s²
Consumable Parts:
(Sold Separately) SA51/16 - Replacement Needle Set (12pc)
4. ASSEMBLY
4.1.
Screw the scaling head fully onto the body as indicated in (fig.1).
4.2.
AIR SUPPLY
WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the needle scaler. Too high an air pressure and
unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
4.2.1.
Ensure needle scaler trigger is not depressed before connecting to the air supply.
4.2.2.
You will require an air pressure of 90psi, and a minimum air flow of 6cfm.
4.2.3.
Drain the air tank daily. Water in the air line will damage the needle scaler.
4.2.4.
Clean air inlet filter weekly. Recommended hook-up procedure is shown in (fig.2).
4.2.5.
Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be
1/4" internal diameter and fittings must have compatible dimensions.
4.2.6.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
© Jack Sealey Limited
COMPOSITE AIR NEEDLE SCALER
MODEL NO:
Wear protective
Wear protective
clothing
gloves
Original Language Version
SA661
Wear a mask
Wear ear
protection
fig.1
SA661 Issue 4 01/07/20

Advertisement

loading

Summary of Contents for Sealey SA661

  • Page 1 SA661 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader hose to the needle scaler (Sealey ref: AH2R or AH2R/38). A quick change coupling may then be used to connect the leader hose to the air line recoil hose (fig.2 &...
  • Page 3 2006/42/EC Machinery Directive This declaration of conformity is issued under the sole responsibility of the manufacturer: Jack Sealey Ltd, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR Declaration of Conformity in accordance with the above Directive(s)� References to harmonised standard(s) EN ISO 11148-4:2010 �������������������������������������������������������������������...