Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury , material damage or capital disadvantages.
ENDA AT 4
P MULTI FUNCTIONAL ANALOG TIMER
ENDA AT 4
P
Thank you for choosing
* 48 x 48mm
sized
.
*
Triggering whit supply voltage
.
*
Triggering output
(OUT1).
*
Contact output for timing function (OUT2).
* 6 Different timing modes for OUT2 (A, B, C, D, E, F).
*
6 Different timing unit selections for OUT2 (S,10S, M, 10M, H, 10H).
* Suitable for 8/11 pin octal or 7/10 screw-terminal connection.
* Start, reset and gate inputs for 10 pins screw-terminal or 11 pin octal connector.
*
CE marked according to European Norms.
ORDER CODE
ATP4 - K07 - UV - 01
Product Basic Code
Panel Mounted
Multi Function Analog Timer
Connection Type
7 Pins screw-terminal K07
10 Pins screw-terminal K10
8 Pins octal
S08
11 Pins octal
S11
Connection Diagram
ENDA ATP4 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The electrical connections must be carried on by a qualified staff and must be according to the relevant
locally applicable regulations. During an installation, all of the cables that are connected to the device must be
free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling.
Make sure that the operation temperature is not exceeded. All input and output lines that are not connected to the
supply network must be laid out as shielded and twisted cables. These cables should not be close to the power
cables or components. The shielding must be grounded on the instrument side.
ENDA
ENDA
INDUSTRIAL ELECTRONICS
INDUSTRIAL ELECTRONICS
ATP4-K10-UV-03 ANALOG TIMER
ATP4-K07-UV-01 ANALOG TIMER
8 680407 709175
8 680407 709069
START
RESET
GATE
CONTACT
250V AC 8A
Made in Turkey
RESISTIVE
Made in Turkey
SN: XXXXXXXXX
SN: XXXXXXXXX
LOAD
NOT :
E
Fuse
SUPPLY :
Switch
F 100 mA 250V AC
90-250
90-250
V AC
(24V AC/DC)
(24V AC/DC)
Supply
Fuse should
Cable size : 1,5mm²
be connected
Multi Functional Analog Timer
Power
indicator
PWR
15
10
5
0
Scale
ENDA
01
0 ..... 1,2
S
03
0 ..... 3
10S
10H
12
0 ... 12
M
H
ATP4
10M
30
0 ... 30
60
0 ... 60
Supply Voltage
Timing unit
UV
90-250V AC
LV
24V AC/DC
ENDA
ENDA
INDUSTRIAL ELECTRONICS
ATP4-S08-LV-30 ANALOG TIMER
ATP4-S11-LV-12 ANALOG TIMER
8 680407 709342
8 680407 709434
4
5
3
6
2
7
1
8
-
SUPPLY
+
CONTACT
24V AC/DC ±10%
250V AC 8A
50/60Hz 10VA
RESISTIVE
CONTACT
LOAD
250V AC 8A
Made in Turkey
Made in Turkey
RESISTIVE
SN: XXXXXXXXX
SN: XXXXXXXXX
LOAD
1) Mains supply cords shall meet the requirements of IEC
60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply
V AC
switch shall bring the identification of the relevant
instrument and it should be easily accessible by the
operator.
Technical Specifications
ENVIRONMENTALCONDITIONS
Ambient/storage temperature
Relative humidity
Rated pollution degree
Height
Do not use the device in locations subject to corrosive and flammable gasses.
Control output
ELECTRICALCHARACTERISTICS
state indicator
Supply voltage
Power consumption
Connection
OUT
Scale
Reset time
Accuracy
20
EMC
25
Safety requirements
Insulation test voltage
30
OUTPUTS
Trigger output
F
Control output
E
Life expectancy for relay
A
B
D
Control output state
C
CONTROL
Timing function
Timing mode
Timing unit
Start input
Reset input
Gate input
HOUSING
Housing type
Dimensions
Weight
Enclosure metarial
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
INDUSTRIAL ELECTRONICS
5 6
7
4
8
3
9
PWR
2
10
1
11
10
-
SUPPLY
+
24V AC/DC ±10%
5
50/60Hz 10VA
0
CONTACT
250V AC 8A
S
RESISTIVE
10S
10H
LOAD
M
H
48mm
1. / 2
0 ... +50°C/-25 ... 70°C There shouldn't be icing or condensation on the environment
(
80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
According to
EN 60529
Front panel
Rear panel
Maximum
2000m
90- 5
2 0V AC 50/60Hz
,
or
24V AC %10, 50/60Hz
±
Maximum 10VA
8/11pins octal connector or 7/10 pins screw-terminal .
0-1.2 , 0-3 , 0- 2 , 0-30 or 0-60.
1
0.3 Seconds for ATP4-UV, 0.01 seconds for ATP4-LV.
Depending on the effect of supply voltage
Depending on the set value settings
Depending on the effect of temperature
EN 61326-1: 2006
EN 61010-1 201 (
:
0 pollution degree 2, over voltage category II
3kV AC min. 1 minute, 4,2kV DC min. 1 minute.
(OUT1)
Relay
: 250V AC, A (
8
resistive load
), NC
(OUT2)
Relay
: 250V AC, A (r
8
esistive load
), NO+NC
Without load
30.000.000
operation
; 250V AC, A re
OUT Led lights up when there is power at the output control, it is flashes as long as the timer is running.
A, B, C, D, E, F Modes can be selected on device.
Second, 10 seconds, minute, 10 minutes, hour, 10 hours units can be selected on device.
Switch inputs for 10 screw-terminal or 11 pin octal connector models.
Switch inputs for 10 screw-terminal or 11 pin octal connector models.
Switch inputs for 10 screw-terminal or 11 pin octal connector models.
Suitable for flush-panel mounting or rail mountable 8/11 pin octal connector.
W
48x 48xD82mm
H
Approx. 170g (after packing)
Self extinguishing plastics
2
1
OUT2
+
8 6 8 0 4 0 7 7 0 9 3 4 2
OUT
1
15
20
67mm
25
14mm
30
1
82mm
ENDA
F
E
A
ATP4
B
D
C
8 6 8 0 4 0 7 7 0 9 0 6 9
2
1
.)
: IP50
: IP20
or 24V DC %10
±
: max %0.2
: max %5
: max %1
)
8
sistive load 1
00.000
operation
.
(Pul
sing time min.
3ms.)
(Pul
sing time min.
3ms.)
(Pul
sing time min.
3ms.)
Panel cut-out
8/11 pin octal
51mm
connector
46mm
Not :
e
Panel thickness
should be
maximum 3mm.
Connection
cables
For removing the device
from the panel:
-
Push in the mounting clamps
7/10 Screw-terminal
1.
Connector
in direction
-
Then, pull out the device
2.
in direction
Need help?