thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY
1.1. GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
familiarise yourself with the application, limitations and potential hazards peculiar to the extractor.
WARNING! Disconnect the unit from the air supply before servicing or performing any maintenance.
Maintain the extractor in good condition (use an authorised service agent).
replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Locate the extractor in a suitable working area, keep area clean and tidy and free from unrelated materials. Ensure there is adequate
ventilation.
WARNING! Use only on level ground or slopes not exceeding 8%.
Ensure there are no flammable or combustible materials near the work area.
Keep children and unauthorised persons away from the working area.
DO NOT use the extractor for a task it was not designed to perform.
DO NOT operate the extractor if any parts are damaged or missing as this may cause failure or possible personal injury.
DO NOT get the extractor wet or use in damp or wet locations or areas where there is condensation.
DO NOT allow untrained persons to operate the extractor.
DO NOT operate the extractor when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT use the extractor where there are flammable liquids, solids or gases such as paint solvents, etc.
DO NOT leave the extractor operating unattended.
2. INTRODUCTION & SPECIFICATION
Ideal for small or large garages and workshops. features soft rubber cylindrical cone to suit most
exhausts. Adjustable height for use on small cars or commercial vehicles. compressed air flow
creates vortex within extractor to ensure all fumes are dispersed (requires air supply). 1.2mtr body
length with additional 3mtr flexible ducting. Mounted vertically on trolley with integral duct compartment
for easy manoeuvrability and compact storage.
Model no: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Efs07
Air Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90psi
Air consumption:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16cfm
Minimum Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185mm
Maximum Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 550mm
Duct Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3mtr
overall Length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2mtr
3.
AIR SUPPLY
the recommended hook-up is shown below.
3.1. Ensure that the air tap (fig.1) is in the "off" position before connecting to the air supply.
3.2. An air pressure of 90psi and an air flow of 16cfm is required.
WARNING! Ensure that the air supply is clean and does not exceed the pressure quoted.
too high an air pressure and/or unclean air will shorten the life of the extractor due to
excessive wear and may be dangerous, causing damage and/or personal injury.
3.3. Drain the compressor's air tank daily. Water in the air line will damage the extractor.
3.4. clean compressor air inlet filter weekly.
3.5. Line pressure should be increased to compensate for unusually long air hoses (over 8
metres). the minimum bore for hose and fittings is 1/4".
3.6. Keep hoses away from heat, oil and sharp edges. check hoses for wear and make certain
that all connections are secure.
InstructIons for:
EXHAUST FUME EXTRACTOR
MoDEL n
Original Language Version
EFS07
:
o
Efs07 Issue:2 - 13/12/11

Advertisement

loading

Summary of Contents for Sealey EFS07

  • Page 1 EFS07 MoDEL n thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, 01284 757500 www.sealey.co.uk...