Regulators:
From left to right: Vaccum, 'Air-assist', Piston down, Piston up. The blow is regulated by time (parameter on
the menu).
(3)
Air outputs are located such that the air
outlet is carried out to the outside, preventing
any dirt may reach the inside of the control
unit.
Connections Board – Power Supply
(4)
The connection board distributes all the
harness between the CPU, solenoid valves,
piston sensors and the power supply (4a).
Power supply: input 220V-50Hz, grounded
and with stabilizer filter; output 24V DC for
solenoid valves and sensors and 3,5V DC for
the CPU PCB (4b).

Checking valves

Pressing blue button you can check is some of the corresponding valves are working:
1
2
3
1 BLOW function
2 VACUUM function
3 AIR ASSIST function