Pre-requisites for Installing Omnia in FlexPay IV
4 – Configuring FlexPay IV
Note: The following instructions are applicable only while performing a FlexPay IV upgrade.
Pre-requisites for Installing Omnia in FlexPay IV
Before starting up and configuring Omnia, ensure that the following pre-requisites are met:
• UPM Software Version 42.11.XX or later is installed.
• PCN Software Version is 4.1.2 or later.
• Omnia parameter i
Note: Always update devices to latest customer approved software.
If the UPM has not been updated or configured, proceed as follows:
Upgrade the UPM to the required software version using the FlexPay IV CRIND (M7)
1
Maintenance tool.
After the SECURE DEVICE UPDATE is complete and the UPM reboots, press 1 to enter the
2
Setup Menu.
Change the connection module of FlexPay IV CRIND (M7) dispenser to Omnia and reboot the
3
dispenser.
After the Omnia parameter is configured, there will be a Card Reader error on the display. The
4
error resolves itself after the Omnia hardware is installed and the CRIND Card Reader
(UX300) IP is set back to the default setting.
When the Omnia parameter is set in the UPM, the internal UPM IP address is set
5
automatically: Side A 172.20.100.1, Side B 172.20.100.3.
Notes: 1) When running Omnia with a Commander POS, the CRIND Baud Rate must be set to
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020
set in the Device Configuration menu.
s
9600 Baud in the CRIND settings in the UPM, and at the Commander POS.
2) All other POS types can remain default 4800 Baud.
Configuring FlexPay IV