Tube heating drop cable
Be careful not to twist fiber especially for using drop cable.
Good
Not Good
No twist
twist
Tube heating Splice-on-Connector
This splicer is applicable to tube-heating for splicer-on-connector.
In case of Fujikura Fuse Connect, removing the right clamp of the heater is
necessary as below.
Remove heater clamp
Loosen the screw in the right side of the heater and remove the clamp by screw
driver. Then, it enables to set the splice-on-connector with the connector
holder.
When using Fujikura Fuse Connect, where a clamp is removed, a
connector holder is set to heater right-hand side, and heating can be
performed.
Please press down a connector holder from a top in the yellow direction of
a line, and attach a screw.
71